Increased cardiac output and maximal oxygen uptake in response to ten sessions of high intensity interval training

被引:18
作者
Astorino, Todd A. [1 ]
Edmunds, Ross M. [1 ]
Clark, Amy [1 ]
King, Leesa [1 ]
Gallant, Rachael M. [1 ]
Namm, Samantha [1 ]
Fischer, Anthony [1 ]
Wood, Kimi A. [1 ]
机构
[1] Calif State Univ San Marcos, Dept Kinesiol, 333 S Twin Oaks Valley Rd,UNIV 320, San Marcos, TX 92096 USA
关键词
High-intensity interval training; Cardiac output; Oxygen consumption; PREDICTING BODY DENSITY; GENERALIZED EQUATIONS; BLOOD-VOLUME; EXERCISE; WOMEN; VO2MAX; PERFORMANCE; CONSUMPTION; IMPEDANCE; CAPACITY;
D O I
10.23736/S0022-4707.16.06606-8
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
BACKGROUND : Increases in maximal oxygen uptake (VO2max) are widely reported in response to completion of high intensity interval training (HIIT), yet the mechanism explaining this result is poorly understood. This study examined changes in VO2max and cardiac output (CO) in response to 10 sessions of low-volume HIIT. METHODS: Participants included 30 active men and women (mean age and VO2max = 22.9 +/- 5.4 years and 39.6 +/- 5.6 mL/kg/min) who performed HIIT and 30 men and women (age and VO2max = 25.7 +/- 4.5 years and 40.7 +/- 5.2 mL/kg/min) who served as non-exercising controls (CON). High intensity interval training consisted of 6-10 s bouts of cycling per session at 90-110 percent peak power output (PPO) interspersed with 75 s recovery. Before and after training, progressive cycling to exhaustion was completed during which CO, stroke volume (SV), and heart rate (HR) were estimated using thoracic impedance. To confirm VO2max attainment, a verification test was completed after progressive cycling at a work rate equal to 110% PPO. RESULTS: Data demonstrated significant improvements in VO2max (2.71 +/- 0.63 L/min to 2.86 +/- 0.63 L/min, P<0.001) and CO max (20.0 +/- 3.1 L/min to 21.7 +/- 3.2 L/min, P=0.04) via HIIT that were not exhibited in CON. Maximal SV was increased in HIIT (P=0.04) although there was no change in maximal HR (P=0.57). CONCLUSIONS: The increase in VO2max seen in response to ten sessions of HIIT is due to improvements in oxygen delivery.
引用
收藏
页码:164 / 171
页数:8
相关论文
共 33 条
[1]   Effects of step duration in incremental ramp protocols on peak power and maximal oxygen consumption [J].
Adami, Alessandra ;
Sivieri, Andrea ;
Moia, Christian ;
Perini, Renza ;
Ferretti, Guido .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2013, 113 (10) :2647-2653
[2]  
Astorino TA, 2008, INT J SPORTS MED, V32, P1
[3]  
Astorino TA, 2015, J SPORT SCI MED, V14, P834
[4]   Individual Responses to Completion of Short-Term and Chronic Interval Training: A Retrospective Study [J].
Astorino, Todd A. ;
Schubert, Matthew M. .
PLOS ONE, 2014, 9 (05)
[5]   Magnitude and time course of changes in maximal oxygen uptake in response to distinct regimens of chronic interval training in sedentary women [J].
Astorino, Todd A. ;
Schubert, Matthew M. ;
Palumbo, Elyse ;
Stirling, Douglas ;
McMillan, David W. ;
Cooper, Christina ;
Godinez, Jackie ;
Martinez, Donovan ;
Gallant, Rachael .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2013, 113 (09) :2361-2369
[6]   Increased cardiac output elicits higher (V) over dotO2max in response to self-paced exercise [J].
Astorino, Todd Anthony ;
McMillan, David William ;
Edmunds, Ross Montgomery ;
Sanchez, Eduardo .
APPLIED PHYSIOLOGY NUTRITION AND METABOLISM, 2015, 40 (03) :223-229
[7]   VO2max Trainability and High Intensity Interval Training in Humans: A Meta-Analysis [J].
Bacon, Andrew P. ;
Carter, Rickey E. ;
Ogle, Eric A. ;
Joyner, Michael J. .
PLOS ONE, 2013, 8 (09)
[8]   Phlebotomy eliminates the maximal cardiac output response to six weeks of exercise training [J].
Bonne, Thomas C. ;
Doucende, Gregory ;
Flueck, Daniela ;
Jacobs, Robert A. ;
Nordsborg, Nikolai B. ;
Robach, Paul ;
Walther, Guillaume ;
Lundby, Carsten .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2014, 306 (10) :R752-R760
[9]   Familial aggregation of VO2max response to exercise training:: results from the HERITAGE Family Study [J].
Bouchard, C ;
An, P ;
Rice, T ;
Skinner, JS ;
Wilmore, JH ;
Gagnon, J ;
Pérusse, L ;
Leon, AS ;
Rao, DC .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (03) :1003-1008
[10]   A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the "direct" Fick method [J].
Charloux, A ;
Lonsdorfer-Wolf, E ;
Richard, R ;
Lampert, E ;
Oswald-Mammosser, M ;
Mettauer, B ;
Geny, B ;
Lonsdorfer, J .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2000, 82 (04) :313-320