Bioelectrical impedance analysis in the assessment of pre-eclampsia

被引:9
作者
Berlit, Sebastian [1 ]
Stojakowits, Marlene [1 ]
Tuschy, Benjamin [1 ]
Weiss, Christel [2 ]
Leweling, Hans [3 ]
Suetterlin, Marc [1 ]
Kehl, Sven [1 ,4 ]
机构
[1] Heidelberg Univ, Dept Obstet & Gynaecol, Univ Med Ctr Mannheim, D-68167 Mannheim, Germany
[2] Heidelberg Univ, Dept Med Stat & Biomath, Univ Med Ctr Mannheim, D-68167 Mannheim, Germany
[3] Heidelberg Univ, Dept Med 4, Univ Med Ctr Mannheim, D-68167 Mannheim, Germany
[4] Erlangen Univ Hosp, Dept Obstet & Gynaecol, Erlangen, Germany
关键词
Pregnancy; Pre-eclampsia; Bioelectrical impedance analysis; BODY-COMPOSITION; BIRTH-WEIGHT; PREGNANCY; WOMEN;
D O I
10.1007/s00404-014-3369-3
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim of this prospective investigation was to assess pre-eclampsia by bioelectrical impedance analysis (BIA). A total of 22 pre-eclamptic as well as matched (patients' age, gestational age, parity, gravidity) healthy pregnant women underwent whole body BIA on admission and then, pre-eclamptic patients, every 2 days until childbirth. For all measured BIA single values and their corresponding reference value mean, standard deviation, minimum and maximum were calculated to compare pre-eclamptic women with corresponding reference values. Furthermore a paired t test and an ANOVA of repeated measurements were performed to detect differences of intraindividual measurements. Subsequently an analysis of variance was accomplished to analyse general changes in the course of time of investigated patients, who were measured more than once. Except for the phase angle, BIA parameters of pre-eclamptic women compared to corresponding reference values were significantly different, suggesting an increase of total body water in pre-eclampsia. Repeated measurements did not reveal statistically significant intra- or interindividual differences in the course of time. Bioelectrical impedance analysis allows differentiating healthy from pre-eclamptic women. Further investigations are needed to analyse if BIA is capable to serve as a prognostic diagnostic tool in the detection of deterioration of pre-eclampsia.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 17 条
  • [1] [Anonymous], 2000, AM J OBSTET GYNECOL, V183, pS1
  • [2] BIOELECTRIC IMPEDANCE PHASE-ANGLE AND BODY-COMPOSITION
    BAUMGARTNER, RN
    CHUMLEA, WC
    ROCHE, AF
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 48 (01) : 16 - 23
  • [3] Berlit S, 2013, IN VIVO, V27, P851
  • [4] Cornish Bruce, 2006, Lymphatic Research and Biology, V4, P47, DOI 10.1089/lrb.2006.4.47
  • [5] Bioimpedance in Pregnant Women with Preeclampsia
    da Silva, Elaine Gomes
    de Barros Leite Carvalhaes, Maria Antonieta
    Hirakawa, Humberto Sadanobu
    da Silva, Evelise Guimaraes
    Peracoli, Jose Carlos
    [J]. HYPERTENSION IN PREGNANCY, 2010, 29 (04) : 357 - 365
  • [6] Bioelectrical impedance analysis during pregnancy and neonatal birth weight
    Ghezzi, F
    Franchi, M
    Balestreri, D
    Lischetti, B
    Mele, MC
    Alberico, S
    Bolis, P
    [J]. EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2001, 98 (02): : 171 - 176
  • [7] Biology and markers of preeclampsia
    Guibourdenche, Jean
    Leguy, Marie-Clemence
    Tsatsaris, Vassilis
    [J]. ANNALES DE BIOLOGIE CLINIQUE, 2013, 71 : 79 - 87
  • [8] Kent E, 2013, OBSTET GYNECOL, V121, P46, DOI [10.1097/AOG.0b013e31827a0052, http://10.1097/AOG.0b013e31827a0052]
  • [9] Body composition during normal pregnancy: reference ranges
    Larciprete, G
    Valensise, H
    Vasapollo, B
    Altomare, F
    Sorge, R
    Casalino, B
    De Lorenzo, A
    Arduini, A
    [J]. ACTA DIABETOLOGICA, 2003, 40 (Suppl 1) : S225 - S232
  • [10] TOTAL-BODY WATER IN PREGNANCY - ASSESSMENT BY USING BIOELECTRICAL-IMPEDANCE
    LUKASKI, HC
    SIDERS, WA
    NIELSEN, EJ
    HALL, CB
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1994, 59 (03) : 578 - 585