Application of carbon sensors for potentiometric determination of copper(II) in water and biological fluids of Wilson disease patients. Studying the surface reaction using SEM, EDX, IR and DFT

被引:32
作者
Frag, Eman Yossri [1 ]
Mohamed, Marwa El Badry [1 ]
Fahim, Elham M. [1 ]
机构
[1] Cairo Univ, Fac Sci, Chem Dept, Gamaa Str, Giza 12613, Egypt
关键词
Ion selective electrodes; Metformin; Tricresylphosphate; Potentiometric determination; Copper; Wilson disease; ION-SELECTIVE ELECTRODES; PASTE ELECTRODE; VOLTAMMETRIC DETECTION; THIURAM DISULFIDE; HYDROCHLORIDE; SAMPLES;
D O I
10.1016/j.bios.2018.07.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The performance characteristics of a new selective and sensitive modified screen printed electrode (MSPE; electrode I) and carbon paste electrode (MCPE; electrode II) based on 2-N, N-dimethylcarbamimidoyl (metformin) as modifier for the potentiometric determination of copper (II) in water sample, serum and urine samples of Wilson disease patients have been optimized. The chemical reaction which happens between Cu (II) and the modifier on the surface of the sensors was investigated with scanning electron microscope (SEM), energy dispersive X-ray analysis (EDX), IR spectra measurement and computational calculations at DFT/B3LYP. The sensors showed perfect potentiometric response for Cu (II) over concentration range of 1.0 x 10(-6) - 1.0 x 10(-2) and 1.0 x 10(-6) - 5.0 x 10(-2) mol L-1 with a detection limit of 1.0 x 10(-6) mol L-l with divalent slope value 30.2 and 31.8 mV decade(-1) over the pH range of 2-6 for MCPE and MSPE, respectively. MSPE was stable with repeatable potential over period of 37 days and exhibits fast response time of 6 and 10 s for MSPE and MCPE, respectively. Also, these sensors exhibited good selectivity towards Cu(II) with respect to other metal ions and have higher antibacterial activity against Staphylococcus aureus as Gram-positive bacteria and Escherichia coli as Gram-negative bacteria. The obtained results using the sensors were in agreement with those obtained using the reported method.
引用
收藏
页码:122 / 128
页数:7
相关论文
共 40 条
[1]   Determination of ultra trace levels of copper in food samples by a highly sensitive adsorptive stripping voltammetric method [J].
Abbasi, Shahryar ;
Khani, Hossein ;
Tabaraki, Reza .
FOOD CHEMISTRY, 2010, 123 (02) :507-512
[2]  
ABE A, 1989, CLIN CHEM, V35, P552
[3]  
Abu-El-Wafa S. M., 1986, INORG CHIM ACTA, V136, P127
[4]  
Ahmad P. H., 2008, J PURE APPL CHEM, V2
[5]   Construction and Performance Characteristics of Modified Screen Printed and Modified Carbon Paste Sensors for Selective Determination of Cu(II) Ion in Different Polluted Water Samples [J].
Ali, Tamer Awad ;
Mohamed, Gehad G. ;
Said, Amal H. .
CHEMICAL ENGINEERING COMMUNICATIONS, 2016, 203 (06) :724-735
[6]  
Alonso ML, 2000, VET J, V160, P259, DOI 10.1053/tvjl.2000.0503
[7]   Speciation of heavy metals in environmental water by ion chromatography coupled to ICP-MS [J].
Ammann, AA .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (03) :448-452
[8]  
[Anonymous], 2009, GAUSSIAN09 REV 2009
[9]  
[Anonymous], 2009, GAUSSVIEW5 0
[10]  
[Anonymous], 2005, INT C HARM TECHN REQ