Comparison of the silicone oil removal rate between vitrectomy and manual syringe negative pressure approach

被引:6
作者
Lin, Zhong [1 ]
Wu, Rong Han [1 ]
Zhou, Ye Hui [1 ]
机构
[1] Wenzhou Med Univ, Hosp Eye, Sch Ophthalmol & Optometry, 270 West Coll Rd, Wenzhou 325027, Zhejiang, Peoples R China
关键词
Silicone oil removal; 23-gauge cannula; Syringe; Vitrectomy; 25-GAUGE SUTURELESS SYSTEM; PARS-PLANA VITRECTOMY; ACTIVE REMOVAL; MANAGEMENT; TAMPONADE; GLAUCOMA; MACHINE; CANNULA;
D O I
10.1007/s10792-016-0319-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of this study was to compare the silicone oil removal rate between vitrectomy and manual syringe negative pressure approach. Thirty-five silicone oil-filled eyes were enrolled and allocated for manual (n = 19) and vitrectomy (n = 16) removal approaches. For manual approach, a 10-ml syringe was connected to the 23-gauge cannula through a short section of blood transfusion tube. Removal was started after pulling and fixing the plunger to the end part. The syringe was pulled away immediately once the residual of silicone oil cannot be observed through the cornea. For vitrectomy approach, the only difference was the source of negative pressure, i.e., the blood transfusion tube was connected to the cannula directly to remove the silicone oil. Silicone oil removal rate was defined as the volume of silicone oil divided by the time taken for removal. The mean time taken for silicone oil removal was faster for manual approach than vitrectomy approach (4.13 +/- 1.41 vs. 6.14 +/- 1.49, p = 0.001). Furthermore, the silicone oil removal rate was larger for manual approach (1.42 +/- 0.30 vs. 0.90 +/- 0.16 ml/min, p < 0.001). No severe intraoperative or postoperative complications were noted for both approaches. The mean IOP at day 1 after surgery was significantly lower than that at baseline in both groups (manual group 10.2 +/- 4.5 vs. 17.6 +/- 5.9, p < 0.001, vitrectomy group 15.1 +/- 7.5 vs. 8.3 +/- 1.9, p < 0.002). All the eyes were recovered at 1 week after surgery. The best-corrected visual acuity (LogMar) at 1 month postoperatively improved compared to that preoperative for both approaches (manual group: 1.10 +/- 0.62 vs. 1.47 +/- 0.76, p = 0.07; vitrectomy group: 1.10 +/- 0.47 vs. 1.11 +/- 0.50, p = 0.62). Both approaches are safe for silicone oil removal. The manual approach is more convenient and efficient.
引用
收藏
页码:921 / 927
页数:7
相关论文
共 23 条
  • [1] Silicone Oil: Different Physical Proprieties and Clinical Applications
    Barca, Francesco
    Caporossi, Tomaso
    Rizzo, Stanislao
    [J]. BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [2] Surgical management of secondary glaucoma after pars plana vitrectomy and silicone oil injection for complex retinal detachment
    Budenz, DL
    Taba, KE
    Feuer, WJ
    Eliezer, R
    Cousins, S
    Henderer, J
    Flynn, HW
    [J]. OPHTHALMOLOGY, 2001, 108 (09) : 1628 - 1632
  • [3] A Low-Molecular-Weight Oil Cleaner For Removal of Leftover Silicone Oil Intraocular Tamponade
    Chan, Yau Kei
    Wong, David
    Yeung, Hiu Kwan
    Man, Ping Kwan
    Shum, Ho Cheung
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (02) : 1014 - 1022
  • [4] CIBIS PA, 1962, ARCH OPHTHALMOL-CHIC, V68, P590
  • [5] INTRACONJUNCTIVAL CAVITARY INCLUSIONS OF SILICONE OIL COMPLICATING RETINAL-DETACHMENT REPAIR
    DONAHUE, SP
    FRIBERG, TR
    JOHNSON, BL
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 114 (05) : 639 - 640
  • [6] Migration of silicone oil into the brain: A complication of intraocular silicone oil for retinal tamponade
    Eller, AW
    Friberg, TR
    Mah, F
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (05) : 685 - 688
  • [7] Fu YJ, 2010, CHIN J AESTH PLAST S, V21, P734
  • [8] Gallemore R, 2006, RETINA, P2231
  • [9] Three hundred and sixty degree retinotomy for retinal detachments with severe proliferative vitreoretinopathy
    Garnier, Steven
    Rahmi, Ahmed
    Grasswil, Cedric
    Kodjikian, Laurent
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (09) : 2081 - 2085
  • [10] Silicone oil removal using vitrectomy machine: A simple and safe technique
    Garodia, VK
    Kulkarni, A
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (06): : 685 - 687