Effect of working fluids on the performance of a novel direct vapor generation solar organic Rankine cycle system

被引:51
作者
Li, Jing [1 ]
Alvi, Jahan Zeb [1 ]
Pei, Gang [1 ]
Ji, Jie [1 ]
Li, Pengcheng [1 ]
Fu, Huide [2 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, 96 Jinzhai Rd, Hefei 230026, Peoples R China
[2] Shenzhen Univ, Dept Energy & Environm Engn, 3688 Nanhai Rd, Shenzhen, Peoples R China
基金
美国国家科学基金会;
关键词
Solar thermal power generation; Organic Rankine cycle; Direct vapor generation; Working fluid; Critical temperature; DIRECT STEAM-GENERATION; ASSISTED HEAT-PUMP; PARABOLIC TROUGH COLLECTORS; WASTE HEAT; RO DESALINATION; WATER-HEATER; TEMPERATURE; RECOVERY; SIMULATION; ORCS;
D O I
10.1016/j.applthermaleng.2015.12.146
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel solar organic Rankine cycle (ORC) system with direct vapor generation (DVG) is proposed. A heat storage unit is embedded in the ORC to guarantee the stability of power generation. Compared with conventional solar ORCs, the proposed system avoids the secondary heat transfer intermediate and shows good reaction to the fluctuation of solar radiation. The technical feasibility of the system is discussed. Performance is analyzed by using 17 dry and isentropic working fluids. Fluid effects on the efficiencies of ORC, collectors and the whole system are studied. The results indicate that the collector efficiency generally decreases while the ORC and system efficiencies increase with the increment in fluid critical temperature. At evaporation temperature of 120 degrees C and solar radiation of 800 Wm(-2), the ORC, collector and overall thermal efficiencies of R236fa are 10.59, 56.14 and 5.08% while their values for Benzene are 12.5, 52.58 and 6.57% respectively. The difference between collector efficiencies using R236fa and Benzene gets larger at lower solar radiation. The heat collection is strongly correlated with latent and sensible heat of the working fluid. Among the fluids, R123 exhibits the highest overall performance and seems to be suitable for the proposed system in the short term. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:786 / 797
页数:12
相关论文
共 52 条
[1]   Direct steam generation in parabolic trough collectors [J].
Alguacil, M. ;
Prieto, C. ;
Rodriguez, A. ;
Lohr, J. .
PROCEEDINGS OF THE SOLARPACES 2013 INTERNATIONAL CONFERENCE, 2014, 49 :21-29
[2]  
Alibaba, 2015, MULT LCD CONTR SOL A
[3]   Effect of dry hydrocarbons and critical point temperature on the efficiencies of organic Rankine cycle [J].
Aljundi, Isam H. .
RENEWABLE ENERGY, 2011, 36 (04) :1196-1202
[4]   A Direct Steam Generation Solar Power Plant With Integrated Thermal Storage [J].
Birnbaum, Juergen ;
Eck, Markus ;
Fichtner, Markus ;
Hirsch, Tobias ;
Lehmann, Dorothea ;
Zimmermann, Gerhard .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (03) :0310141-0310145
[5]   Solar-assisted heat pump - A sustainable system for low-temperature water heating applications [J].
Chaturvedi, S. K. ;
Gagrani, V. D. ;
Abdel-Salam, T. M. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 77 :550-557
[6]   Two-stage direct expansion solar-assisted heat pump for high temperature applications [J].
Chaturvedi, S. K. ;
Abdel-Salam, T. M. ;
Sreedharan, S. S. ;
Gorozabel, F. B. .
APPLIED THERMAL ENGINEERING, 2009, 29 (10) :2093-2099
[7]   A new design method for Organic Rankine Cycles with constraint of inlet and outlet heat carrier fluid temperatures coupling with the heat source [J].
Chen, Qicheng ;
Xu, Jinliang ;
Chen, Hongxia .
APPLIED ENERGY, 2012, 98 :562-573
[8]  
Clark Energy, 2015, GE MOD CLEAN CYCL 12
[9]   Design recommendations for solar organic Rankine cycle (ORC)-powered reverse osmosis (RO) desalination [J].
Delgado-Torres, Agustin M. ;
Garcia-Rodriguez, Lourdes .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (01) :44-53
[10]   Analysis and optimization of the low-temperature solar organic Rankine cycle (ORC) [J].
Delgado-Torres, Agustin M. ;
Garcia-Rodriguez, Lourdes .
ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (12) :2846-2856