New techniques for dissolved gas-in-oil analysis

被引:81
作者
Duval, M [1 ]
机构
[1] Inst Rech Hydro Quebec, Varennes, PQ J3X 1S1, Canada
关键词
dissolved gas analysis; laboratory techniques; gas extraction;
D O I
10.1109/MEI.2003.1192031
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
TF-07 (Head Space, Shake Test, Mercury-Free Toepler, and Mercury-Free Partial Degassing) just completed evaluation of the new Mercury-Free gas extraction techniques for routine dissolved gas analysis (DGA) with an accuracy and reliability comparable to that provided by the older standard techniques. Several of these new techniques allow the analysis of more oil samples per year at a lower cost per analysis, with standard Partial Degassing remaining competitive in that respect.
引用
收藏
页码:6 / 15
页数:10
相关论文
共 12 条
  • [1] *ASTM, 2001, 361201 ASTM D
  • [2] MONITOR FOR HYDROGEN DISSOLVED IN TRANSFORMER OIL
    BELANGER, G
    DUVAL, M
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1977, 12 (05): : 334 - 340
  • [3] Berube R., 1996, ELECT TODAY, V8, P21
  • [4] *CIGRE TASK FORC, 150107 CIGRE TASK FO
  • [5] DUVAL M, 1984, PREPARATION STANDARD
  • [6] GALBERT J, 1996, IEEE POW ENG SOC M
  • [7] HINSHAW JV, 1989, P 1989 AN CHEM C PIT
  • [8] *IEC, 1992, IEC PUBL
  • [9] STATIC HEADSPACE GAS-CHROMATOGRAPHIC DETERMINATION OF FAULT GASES DISSOLVED IN TRANSFORMER INSULATING OILS
    LEBLANC, Y
    GILBERT, R
    DUVAL, M
    HUBERT, J
    [J]. JOURNAL OF CHROMATOGRAPHY, 1993, 633 (1-2): : 185 - 193
  • [10] MCGARVEY TJ, 1990, AUTOMATED SYSTEM ANA