Fluorescent Nanohybrid of Gold Nanoclusters and Quantum Dots for Visual Determination of Lead Ions

被引:87
作者
Zhu, Houjuan [1 ,2 ]
Yu, Tao [3 ]
Xu, Hongda [1 ,2 ]
Zhang, Kui [1 ]
Jiang, Hui [3 ]
Zhang, Zhongping [1 ]
Wang, Zhenyang [1 ]
Wang, Suhua [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Intelligent Machines, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China
[3] Res Inst NBC Def, State Key Lab NBC Protect China, Beijing 102205, Peoples R China
基金
中国国家自然科学基金;
关键词
visual detection; nanohybrid fluorescence sensor; lead ions; poly(vinyl alcohol) film; gold nanocluster; RATIOMETRIC FLUORESCENCE; ENERGY-TRANSFER; CHEMOSENSOR; PROBE; PB2+; IDENTIFICATION; NANOCRYSTALS; RESIDUES; SENSORS; DESIGN;
D O I
10.1021/am5064603
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Highly green emissive gold nanoclusters (Au NCs) are synthesized using glutathione as a stabilizing agent and mercaptopropionic acid as a ligand, and the intensity of fluorescence is specifically sensitive to lead ions. We then fabricated a ratiometric fluorescence nanohybrid by covalently linking the green Au NCs to the surface of silica nanoparticles embedded with red quantum dots (QDs) for on-site visual determination of lead ions. The green fluorescence can be selectively quenched by lead ions, whereas the red fluorescence is inert to lead ions as internal reference. The different response of the two emissions results in a continuous fluorescence color change from green to yellow that can be clearly observed by the naked eyes. The nanohybrid sensor exhibits high sensitivity to lead ions with a detection limit of 3.5 nM and has been demonstrated for determination of lead ions in real water samples including tap water, mineral water, groundwater, and seawater. For practical application, we dope the Au NCs in poly(vinyl alcohol) (PVA) film and fabricate fluorescence test strips to directly detect lead ions in water. The PVA-film method has a visual detection limit of 0.1 mu M, showing its promising application for on-site identification of lead ions without the need for elaborate equipment.
引用
收藏
页码:21461 / 21467
页数:7
相关论文
共 59 条
[1]   ELECTROTHERMAL ISOTOPE-DILUTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY METHOD FOR THE DETERMINATION OF SUB-NG ML(-1) LEVELS OF LEAD IN HUMAN PLASMA [J].
BOWINS, RJ ;
MCNUTT, RH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (11) :1233-1236
[3]   Ultrasensitive and rapid lead sensing in water based on environmental friendly and high luminescent L-glutathione-capped-ZnSe quantum dots [J].
Cai, Zhaoxia ;
Shi, Baoqin ;
Zhao, Lei ;
Ma, Meihu .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2012, 97 :909-914
[4]   A highly selective fluorescent chemosensor for lead ions [J].
Chen, CT ;
Huang, WP .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (22) :6246-6247
[5]   Developmental immunotoxicology of lead [J].
Dietert, RR ;
Lee, JE ;
Hussain, I ;
Piepenbrink, M .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 2004, 198 (02) :86-94
[6]   On the Design of Fluorescent Ratiometric Nanosensors [J].
Doussineau, Tristan ;
Schulz, Anja ;
Lapresta-Fernandez, Alejandro ;
Moro, Artur ;
Koersten, Susanne ;
Trupp, Sabine ;
Mohr, Gerhard J. .
CHEMISTRY-A EUROPEAN JOURNAL, 2010, 16 (34) :10290-10299
[7]   Fluorescent chemodosimeters using "mild" chemical events for the detection of small anions and cations in biological and environmental media [J].
Du, Jianjun ;
Hu, Mingming ;
Fan, Jiangli ;
Peng, Xiaojun .
CHEMICAL SOCIETY REVIEWS, 2012, 41 (12) :4511-4535
[8]   Fluoro- and Chromogenic Chemodosimeters for Heavy Metal Ion Detection in Solution and Biospecimens [J].
Duong Tuan Quang ;
Kim, Jong Seung .
CHEMICAL REVIEWS, 2010, 110 (10) :6280-6301
[9]   Fluorescent gold clusters as nanosensors for copper ions in live cells [J].
Durgadas, C. V. ;
Sharma, C. P. ;
Sreenivasan, K. .
ANALYST, 2011, 136 (05) :933-940
[10]   Controlling the color space response of colorimetric luminescent oxygen sensors [J].
Evans, R. C. ;
Douglas, P. .
ANALYTICAL CHEMISTRY, 2006, 78 (16) :5645-5652