Experimental Study on a Novel Dry Connection for a Precast Concrete Beam-To-Column Joint

被引:15
作者
Zhong, Yachao [1 ,2 ]
Xiong, Feng [1 ,2 ]
Chen, Jiang [1 ,2 ]
Deng, Ai [3 ]
Chen, Wen [2 ,4 ]
Zhu, Xulong [2 ]
机构
[1] Sichuan Univ, Minist Educ, Key Lab Deep Underground Sci & Engn, Chengdu 610065, Sichuan, Peoples R China
[2] Sichuan Univ, Coll Architecture & Environm, Chengdu 610065, Sichuan, Peoples R China
[3] Sichuan Univ, Southwest Elect Power Design Inst, Chengdu 610056, Sichuan, Peoples R China
[4] Southwest Univ Sci & Technol, Sch Environm & Resource, Mianyang 621010, Sichuan, Peoples R China
关键词
precast concrete; beam-to-column joint; seismic performance; bolt connection; SEISMIC RESPONSE; BEHAVIOR; FRAMES;
D O I
10.3390/su11174543
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
At present, precast buildings have become the focus of the building industrialization, and the precast concrete frame structure has been widely used in the construction industry. On this background, a novel precast concrete frame with a bolt connection joint was proposed in this paper. The novel connections include connection steel plates, bolts and rubber layers. To investigate the seismic performance of the precast structure, two full-scale, precast, cruciform, reinforced concrete specimens, and a monolithic counterpart, are tested under reversed cyclic loading. For the precast specimens, two different thickness rubber layers are applied in the connection region, respectively. Seismic behavior was evaluated based on failure mode, hysteretic behavior, stiffness degeneration, ductility and energy dissipation. The results indicated that precast specimens had almost the same ultimate bearing capacity as the cast-in-place ones, and the failure mode is also the same. The precast specimens satisfied the strong column-weak beam design concept. Additionally, the initial stiffness is obviously decreased by adding rubber washers at the joint region, showing a semi-rigid characteristic. At the end of this paper, an equivalent stiffness computation method of the precast joint is discussed.
引用
收藏
页数:22
相关论文
共 32 条
  • [1] Strengthening of precast RC beam-column connections for progressive collapse mitigation using bolted steel plates
    Al-Salloum, Yousef A.
    Alrubaidi, Mohammed A.
    Elsanadedy, Hussein M.
    Almusallam, Tarek H.
    Iqbal, Rizwan A.
    [J]. ENGINEERING STRUCTURES, 2018, 161 : 146 - 160
  • [2] Nonlinear Cyclic Behaviour of Precast Concrete Frame Sub-Assemblies With "Dry" End Plate Connection
    Aninthaneni, P. K.
    Dhakal, R. P.
    Marshall, J.
    Bothara, J.
    [J]. STRUCTURES, 2018, 14 : 124 - 136
  • [3] [Anonymous], 1995, PCI J, DOI DOI 10.15554/PCIJ.01011995.94.103
  • [4] Bao YH, 2017, PCI J, P53
  • [5] Boresi A.P., 1985, ADV MECH MAT, V6
  • [6] [蔡建国 CAI Jianguo], 2009, [中山大学学报. 自然科学版, Acta Scientiarum Naturalium Universitatis Sunyatseni], V48, P136
  • [7] China Academy of Building Research, 2009, 22812010 GBT
  • [8] China Academy of Building Research, 2012, 501522012 GBT
  • [9] China Academy of Building Research, 2010, 500102010 GB
  • [10] China Academy of Building Research, 2010, 1012015 JGJT