Three-dimensional finite element analysis of intramedullary nail with different materials in the treatment of intertrochanteric fractures

被引:12
作者
Wang, Chenyan [1 ]
Li, Xiaona [1 ]
Chen, Weiyi [1 ]
Wang, Changjiang [2 ]
Guo, Yuan [1 ]
Guo, Hongmei [1 ]
机构
[1] Taiyuan Univ Technol, Coll Biomed Engn, 79 Yingze West Rd, Taiyuan 030024, Shanxi, Peoples R China
[2] Univ Sussex, Sch Engn & Informat, Brighton BN1 9QJ, E Sussex, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2021年 / 52卷 / 04期
基金
中国国家自然科学基金;
关键词
Intramedullary nail; Intertrochanteric fracture; Stress shielding; PEEK; FG materials; Finite element analysis; FIBER-REINFORCED PEEK; TROCHANTERIC FRACTURES; MECHANICAL-PROPERTIES; CORTICAL BONE; GAMMA-NAIL; FEMUR; STRESS; IMPLANT; FIXATION; FORCES;
D O I
10.1016/j.injury.2020.10.102
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Intramedullary nails are the common treatment options for femoral intertrochanteric fractures. However, aseptic loosening is considered to be one of the primary forms of failure that can be caused by the stress shielding between the bone and implants. The matching in mechanical properties of implant and bone is a key issue to prevent this failure. Polyetheretherketone (PEEK) and Function-graded (FG) materials are widely used in clinical because of their excellent mechanical properties. In this study, to investigate the biomechanical behaviors of intramedullary nails made of Ti-6Al-4V alloy, Stainless Steel (SS), PEEK and two FG materials, three-dimensional finite element models of intertrochanteric fracture femur with intramedullary nail were constructed with ABAQUS. The maximum von Mises stress on the femoral fracture surface fixed by PEEK intramedullary nail was the largest, followed by FG intramedullary nail, which help stimulate bone growth and subsequently reduce fracture healing time. Compared with traditional metal intramedullary nails, PEEK and FG implants might increase von Mises stress along the same path in the proximal femur. The results showed that PEEK and FG intramedullary nails obviously changed the stress distributions in the bone and reduced stress shielding. This finding indicated that PEEK and FG intramedullary nails have the potential to become alternatives to the conventional metal intramedullary nails. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:705 / 712
页数:8
相关论文
共 39 条
[1]   In vitro assessment of Function Graded (FG) artificial Hip joint stem in terms of bone/cement stresses: 3D Finite Element (FE) study [J].
Al-Jassir, Fawzi F. ;
Fouad, H. ;
Alothman, Othaman Y. .
BIOMEDICAL ENGINEERING ONLINE, 2013, 12
[2]   The effect of boundary and loading conditions on patient classification using finite element predicted risk of fracture [J].
Altai, Zainab ;
Qasim, Muhammad ;
Li, Xinshan ;
Viceconti, Marco .
CLINICAL BIOMECHANICS, 2019, 68 :137-143
[3]   Image-based anatomical reconstruction and pharmaco-mediated bone remodeling model applied to a femur with subtrochanteric fracture: A subject-specific finite element study [J].
Bahia, Miguel T. ;
Hecke, Mildred B. ;
Mercuri, Emilio G. F. .
MEDICAL ENGINEERING & PHYSICS, 2019, 69 :58-71
[4]   Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue [J].
Bayraktar, HH ;
Morgan, EF ;
Niebur, GL ;
Morris, GE ;
Wong, EK ;
Keaveny, TM .
JOURNAL OF BIOMECHANICS, 2004, 37 (01) :27-35
[5]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[6]  
Buckwalter J A, 1999, J Am Acad Orthop Surg, V7, P291
[7]   Effects of stemmed and nonstemmed hip replacement on stress distribution of proximal femur and implant [J].
Chen, Chun-Ming ;
Tsai, Wen-Chi ;
Lin, Shang-Chih ;
Tseng, Ching-Shiow .
BMC MUSCULOSKELETAL DISORDERS, 2014, 15
[8]   Fracture characteristics of PEEK at various stress triaxialities [J].
Chen, Fei ;
Gatea, Shakir ;
Ou, Hengan ;
Lu, Bin ;
Long, Hui .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 64 :173-186
[9]   A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEK [J].
Chen, Xin ;
Mao, Bochun ;
Zhu, Zhuoli ;
Yu, Jiayi ;
Lu, Yuqing ;
Zhang, Qianqian ;
Yue, Li ;
Yu, Haiyang .
SCIENTIFIC REPORTS, 2019, 9 (1)
[10]   Effect of Femoral Head Size, Subject Weight, and Activity Level on Acetabular Cement Mantle Stress Following Total Hip Arthroplasty [J].
Del-Valle-Mojica, Jose-Francisco ;
Alonso-Rasgado, Teresa ;
Jimenez-Cruz, David ;
Bailey, Colin G. ;
Board, Tim N. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2019, 37 (08) :1771-1783