Assessment of atrial septal defect size with 3D-transesophageal echocardiography:: Comparison with balloon method

被引:34
作者
Abdel-Massih, T
Dulac, Y
Taktak, A
Aggoun, Y
Massabuau, P
Elbaz, M
Carrié, D
Acar, P
机构
[1] Hop Enfants, Unite Cardiol Pediat, F-31026 Toulouse 3, France
[2] Unite Cardiol Intervent, Toulouse, France
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2005年 / 22卷 / 02期
关键词
atrial septal defect; three-dimensional echocardiography; balloon stretched diameter;
D O I
10.1111/j.0742-2822.2005.03153.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transcatheter closure of atrial septal defect (ASD) is an alternative approach to surgery in selected patients. Balloon stretched diameter (BSD) is considered as the standard way of measuring ASD size. Three-dimensional transesophageal echocardiography (3D-TEE) provides views of the ASD allowing its measurement and identifying its spatial relation with neighboring structures. Our aim was to compare the BSD and 3D-TEE methods to measure the ASD size before transcatheter closure. Methods and Results: Seventy-six consecutive patients were enrolled for ASD device closure. Three-dimensional transesophageal echocardiography and balloon sizing were adequately performed in 70 patients before the defect closure. The mean maximal diameter measured by 3D-TEE was 20 15 mm (range 10-28) while the mean BSD was 22 +/- 4.8 mm (range 9-31). When comparing the 3D-TEE and transcatheter measurements, there was a good correlation between the two methods (y = 3.15 + 0.77x; r = 0.8). The defect as viewed by 3D-TEE was unique in 54 patients and multiple in 16 patients. Inpatients with a single defect, the correlation between the two methods was high (y = 1.74 + 0.84x; r = 0.85) while patients with multiple ASDs, the correlation was poor (y = 12.4 + 0.4x; r = 0.45). Transcatheter closure was performed successfully in 86%. The mean size of the Amplatzer device was 23 +/- 4.8 mm (range 4-32). The reference to choose the size of the device was the BSD in single defects and the 3D-TEE maximal diameter in multiple defects. Conclusion: Three-dimensional transesophageal echocardiography and transcatheter methods are two complementary techniques for the success of transcatheter ASDs closure.
引用
收藏
页码:121 / 127
页数:7
相关论文
共 26 条
  • [1] Three-dimensional echocardiographic analysis of valve anatomy as a determinant of mitral regurgitation after surgery for atrioventricular septal defects
    Acar, P
    Laskari, C
    Rhodes, J
    Pandian, N
    Warner, K
    Marx, G
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (05) : 745 - 749
  • [2] Influence of atrial septal defect anatomy in patient selection and assessment of closure with the Cardioseal device - A three-dimensional transoesophageal echocardiographic reconstruction
    Acar, P
    Saliba, Z
    Bonhoeffer, P
    Aggoun, Y
    Bonnet, D
    Sidi, D
    Kachaner, J
    [J]. EUROPEAN HEART JOURNAL, 2000, 21 (07) : 573 - 581
  • [3] Left ventricular ejection fraction in children measured by three-dimensional echocardiography using a new transthoracic integrated 3D-probe - A comparison with equilibrium radionuclide angiography
    Acar, P
    Maunoury, C
    Antonietti, T
    Bonnet, D
    Sidi, D
    Kachaner, J
    [J]. EUROPEAN HEART JOURNAL, 1998, 19 (10) : 1583 - 1588
  • [4] Comparison of transthoracic and transesophageal three-dimensional echocardiography for assessment of atrial septal defect diameter in children
    Acar, P
    Dulac, Y
    Roux, D
    Rougé, P
    Duterque, D
    Aggoun, Y
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (04) : 500 - +
  • [5] BEERMAN LB, 1987, PAEDIAT CARDIOLOGY, P541
  • [6] BENSON LN, 1992, NEONATAL HEART DIS, P633
  • [7] Transcatheter closure as standard treatment for most interatrial defects:: experience in 200 patients treated with the Amplatzer™ Septal Occluder
    Berger, F
    Ewert, P
    Björnstad, PG
    Dähnert, I
    Krings, G
    Brilla-Austgenat, I
    Vogel, M
    Lange, PE
    [J]. CARDIOLOGY IN THE YOUNG, 1999, 9 (05) : 468 - 473
  • [8] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [9] Transcatheter closure of multiple atrial septal defects - Initial results and value of two- and three-dimensional transoesophageal echocardiography
    Cao, QL
    Radtke, W
    Berger, F
    Zhu, W
    Hijazi, ZM
    [J]. EUROPEAN HEART JOURNAL, 2000, 21 (11) : 941 - 947
  • [10] Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): multicentre UK experience
    Chan, KC
    Godman, MJ
    Walsh, K
    Wilson, N
    Redington, A
    Gibbs, JL
    [J]. HEART, 1999, 82 (03) : 300 - 306