Validation of wearable visual feedback for retraining foot progression angle using inertial sensors and an augmented reality headset

被引:60
作者
Karatsidis, Angelos [1 ,2 ]
Richards, Rosie E. [3 ]
Konrath, JasonM. [1 ]
van den Noort, Josien C. [3 ,4 ]
Schepers, H. Martin [1 ]
Bellusci, Giovanni [1 ]
Harlaar, Jaap [3 ,5 ]
Veltink, Peter H. [2 ]
机构
[1] Xsens Technol BV, Pantheon 6, NL-7521 PR Enschede, Netherlands
[2] Univ Twente, Tech Med Ctr, Dept Biomed Signals & Syst BSS, Enschede, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Amsterdam Movement Sci, Dept Rehabil Med, Amsterdam, Netherlands
[4] Amsterdam Movement Sci, Dept Radiol & Nucl Med, Acad Med Ctr, MIQC, Amsterdam, Netherlands
[5] Delft Univ Technol, Dept Biomech Engn, Delft, Netherlands
来源
JOURNAL OF NEUROENGINEERING AND REHABILITATION | 2018年 / 15卷
关键词
Foot progression angle; Inertial sensors; Real-time biofeedback; Augmented reality headset; Gait retraining; Knee osteoarthritis; KNEE ADDUCTION MOMENT; TOE-OUT GAIT; TIME BIOFEEDBACK; HAPTIC FEEDBACK; HUMAN MOVEMENT; OSTEOARTHRITIS; REDUCE; INDIVIDUALS; STRATEGIES; WALKING;
D O I
10.1186/s12984-018-0419-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Gait retraining interventions using real-time biofeedback have been proposed to alter the loading across the knee joint in patients with knee osteoarthritis. Despite the demonstrated benefits of these conservative treatments, their clinical adoption is currently obstructed by the high complexity, spatial demands, and cost of optical motion capture systems. In this study we propose and evaluate a wearable visual feedback system for gait retraining of the foot progression angle (FPA). Methods: The primary components of the system are inertial measurement units, which track the human movement without spatial limitations, and an augmented reality headset used to project the visual feedback in the visual field. The adapted gait protocol contained five different target angles ranging from 15 degrees toe-out to 5 degrees toe-in. Eleven healthy participants walked on an instrumented treadmill, and the protocol was performed using both an established laboratory visual feedback driven by optical motion capture, and the proposed wearable system. Results and conclusions: The wearable system tracked FPA with an accuracy of 2.4 degrees RMS and ICC=0.94 across all target angles and subjects, when compared to an optical motion capture reference. In addition, the effectiveness of the biofeedback, reflected by the number of steps with FPA value +/- 2 degrees from the target, was found to be around 50% in both wearable and laboratory approaches. These findings demonstrate that retraining of the FPA using wearable inertial sensing and visual feedback is feasible with effectiveness matching closely an established laboratory method. The proposed wearable setup may reduce the complexity of gait retraining applications and facilitate their transfer to routine clinical practice.
引用
收藏
页数:12
相关论文
共 61 条
  • [1] Kinematic analysis of over-determinate biomechanical systems
    Andersen, M. S.
    Damsgaard, M.
    Rasmussen, J.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2009, 12 (04) : 371 - 384
  • [2] Gait retraining to reduce the knee adduction moment through real-time visual feedback of dynamic knee alignment
    Barrios, Joaquin A.
    Crossley, Kay M.
    Davis, Irene S.
    [J]. JOURNAL OF BIOMECHANICS, 2010, 43 (11) : 2208 - 2213
  • [3] Body-Worn Sensor Design: What Do Patients and Clinicians Want?
    Bergmann, J. H. M.
    McGregor, A. H.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (09) : 2299 - 2312
  • [4] Comparison of the metabolic energy cost of overground and treadmill walking in older adults
    Berryman, Nicolas
    Gayda, Mathieu
    Nigam, Anil
    Juneau, Martin
    Bherer, Louis
    Bosquet, Laurent
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (05) : 1613 - 1620
  • [5] Methodological differences in clinical trials evaluating nonpharmacological and pharmacological treatments of hip and knee osteoarthritis
    Boutron, I
    Tubach, F
    Giraudeau, B
    Ravaud, P
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 290 (08): : 1062 - 1070
  • [6] The relationship between toe-out angle during gait and progression of medial tibiofemoral osteoarthritis
    Chang, Alison
    Hurwitz, Debra
    Dunlop, Dorothy
    Song, Jing
    Cahue, September
    Hayes, Karen
    Sharma, Leena
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2007, 66 (10) : 1271 - 1275
  • [7] Wearable lower limb haptic feedback device for retraining Foot Progression Angle and Step Width
    Chen, Daniel K. Y.
    Haller, Markus
    Besier, Thor F.
    [J]. GAIT & POSTURE, 2017, 55 : 177 - 183
  • [8] Validity of the Microsoft Kinect for providing lateral trunk lean feedback during gait retraining
    Clark, Ross A.
    Pua, Yong-Hao
    Bryant, Adam L.
    Hunt, Michael A.
    [J]. GAIT & POSTURE, 2013, 38 (04) : 1064 - 1066
  • [9] Guidelines - Care and management of osteoarthritis in adults: summary of NICE guidance
    Conaghan, Philip G.
    Dickson, John
    Grant, Robert L.
    [J]. BRITISH MEDICAL JOURNAL, 2008, 336 (7642): : 502 - 503
  • [10] Magnetic distortion in motion labs, implications for validating inertial magnetic sensors
    de Vries, W. H. K.
    Veeger, H. E. J.
    Baten, C. T. M.
    van der Helm, F. C. T.
    [J]. GAIT & POSTURE, 2009, 29 (04) : 535 - 541