Longitudinal Shapes of the Tibia and Femur are Unrelated and Variable

被引:46
作者
Howell, Stephen M. [1 ]
Kuznik, Kyle [2 ]
Hull, Maury L. [1 ]
Siston, Robert A. [3 ,4 ]
机构
[1] Univ Calif Davis, Dept Mech Engn, Davis, CA 95616 USA
[2] OtisMed Corp, Alameda, CA USA
[3] Ohio State Univ, Dept Mech Engn, Columbus, OH 43210 USA
[4] Ohio State Univ, Dept Orthopaed, Columbus, OH 43210 USA
关键词
TOTAL KNEE ARTHROPLASTY; FEMORAL INTRAMEDULLARY GUIDES; NORMAL AXIAL ALIGNMENT; LOWER-EXTREMITY; FUNCTIONAL AXES; OSTEOARTHRITIS; REPLACEMENT; EPICONDYLAR; ACCURACY; ROTATION;
D O I
10.1007/s11999-009-0984-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In general practice, short films of the knee are used to assess component position and define the entry point for intramedullary femoral alignment in TKAs; however, whether it is justified to use the short film commonly used in research settings and everyday practice as a substitute for the whole leg view is controversial and needs clarification. In 138 long leg CT scanograms we measured the angle formed by the anatomic axis of the proximal fourth of the tibia and the mechanical axis of the tibia, the angle formed by the anatomic axis of the distal fourth of the femur and the mechanical axis of the femur, the "bow" of the tibia (as reflected by the offset of the anatomic axis from the center of the talus), and the "bow" of the femur (as reflected by the offset of the anatomic axis from the center of the femoral head). Because the angle formed by these axes and the bow of the tibia and femur have wide variability in females and males, a short film of the knee should not be used in place of the whole leg view when accurate assessment of component position and limb alignment is essential. A previous study of normal limbs found that only 2% of subjects have a neutral hip-knee-ankle axis, which can be explained by the wide variability of the bow in the tibia and femur and the lack of correlation between the bow of the tibia and femur in a given limb as shown in the current study.
引用
收藏
页码:1142 / 1148
页数:7
相关论文
共 32 条
[1]   Computer-assisted surgery: A wine before its time [J].
Alden, Kris J. ;
Pagnano, Mark W. .
ORTHOPEDICS, 2008, 31 (09) :936-+
[2]  
Brouwer R W, 2007, J Knee Surg, V20, P210
[3]   Axial lower-limb alignment: Comparison of knee geometry in normal volunteers and osteoarthritis patients [J].
Cooke, D ;
Scudamore, A ;
Li, J ;
Wyss, U ;
Bryant, T ;
Costigan, P .
OSTEOARTHRITIS AND CARTILAGE, 1997, 5 (01) :39-47
[4]   Tibial axis and patellar position relative to the femoral epicondylar axis during squatting [J].
Coughlin, KM ;
Incavo, SJ ;
Churchill, DL ;
Beynnon, BD .
JOURNAL OF ARTHROPLASTY, 2003, 18 (08) :1048-1055
[5]  
Derek T, 2007, J RHEUMATOL, V34, P1796
[6]   Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality [J].
Eckhoff, DG ;
Bach, JM ;
Spitzer, VM ;
Reinig, KD ;
Bagur, MM ;
Baldini, TH ;
Flannery, NMP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A :71-80
[7]   Difference between the epicondylar and cylindrical axis of the knee [J].
Eckhoff, Donald ;
Hogan, Craig ;
DiMatteo, Laura ;
Robinson, Mitch ;
Bach, Joel .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (461) :238-244
[8]   Is there an alternative to the full-leg radiograph for determining knee joint alignment in osteoarthritis? [J].
Hinman, RS ;
May, RL ;
Crossley, KM .
ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH, 2006, 55 (02) :306-313
[9]  
HOLLISTER AM, 1993, CLIN ORTHOP RELAT R, P259
[10]   Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients [J].
Howell, Stephen M. ;
Kuznik, Kyle ;
Hull, Maury L. ;
Siston, Robert A. .
ORTHOPEDICS, 2008, 31 (09) :857-863