Amperometric glutamate biosensor based on poly(o-phenylenediamine) film electrogenerated onto modified carbon paste electrodes

被引:52
|
作者
Alvarez-Crespo, SL [1 ]
Lobo-Castanon, MJ [1 ]
Miranda-Ordieres, AJ [1 ]
Tunon-Blanco, P [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Oviedo 33006, Asturias, Spain
来源
BIOSENSORS & BIOELECTRONICS | 1997年 / 12卷 / 08期
关键词
glutamate; poly(O-phenylenediamine) amperometric biosensor; carbon paste;
D O I
10.1016/S0956-5663(97)00041-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A glutamate biosensor was developed by electropolymerizing o-phenylenediamine on a dehydrogenase-NAD(+) modified carbon paste electrode. The amperometric response to glutamate was obtained by means of the electrocatalytic oxidation of the enzymatically produced NADH, at an applied potential close to OV (Ag/AgCl). After optimizing carbon paste composition, polymer thickness and operating variables, a linear amperometric response to glutamate was obtained within the concentration range 5.0 x 10(-6)-7.8 x 10(-5) M with a detection limit of 3.8 x 10(-6) M. The biosensor was applied to the determination of glutamate in chicken bouillon cubes. Good accuracy was found with respect to a reference enzymatic spectrophotometric method. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:739 / 747
页数:9
相关论文
共 50 条
  • [21] Enhanced selectivity and sensitivity of first-generation enzyme electrodes based on the coupling of rhodinized carbon paste transducers and permselective poly(o-phenylenediamine) coatings
    Wang, J
    Chen, L
    Liu, J
    Lu, F
    ELECTROANALYSIS, 1996, 8 (12) : 1127 - 1130
  • [22] Development of an Amperometric Enzyme Electrode based on Poly(o-Phenylenediamine) for the Determination of Total Cholesterol in Serum
    Zeybek, Derya Koyuncu
    Zeybek, Bulent
    Pekmez, Nuran Ozcicek
    Pekyardimci, Sule
    Kilic, Esma
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (12) : 2222 - 2231
  • [23] AMPEROMETRIC BIOSENSOR FOR ETHANOL BASED ON A PHENOTHIAZINE DERIVATIVE MODIFIED CARBON PASTE ELECTRODE
    Gligor, Delia
    Csoregi, Elisabeth
    Popescu, Ionel Catalin
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2008, 53 (01): : 55 - 62
  • [24] Sensitive amperometric pyridoxine sensor based on self-assembled Prussian blue nanoparticle-modified poly(o-phenylenediamine)/glassy carbon electrode
    Ojani, Reza
    Hamidi, Parisa
    Raoof, Jahan-Bakhsh
    APPLIED ORGANOMETALLIC CHEMISTRY, 2016, 30 (05) : 297 - 303
  • [26] DNA biosensor based on carbon paste electrodes modified by polymer multilayer
    Ioannou, AK
    Pantazaki, AA
    Girousi, STH
    Millot, MC
    Vidal-Madjar, C
    Voulgaropoulos, AN
    ELECTROANALYSIS, 2006, 18 (05) : 456 - 464
  • [27] Poly(o-phenylenediamine) ultra-thin polymer-film composite membranes for enzyme electrodes
    Myler, S
    Eaton, S
    Higson, SPJ
    ANALYTICA CHIMICA ACTA, 1997, 357 (1-2) : 55 - 61
  • [28] Development of three-enzyme lactose amperometric biosensor modified by nanosized poly (meta-phenylenediamine) film
    Pyeshkova, V. M.
    Dudchenko, O. Y.
    Soldatkin, O. O.
    Alekseev, S. A.
    Seker, T.
    Kurc, B. Akata
    Dzyadevych, S. V.
    APPLIED NANOSCIENCE, 2022, 12 (04) : 1267 - 1274
  • [29] Development of three-enzyme lactose amperometric biosensor modified by nanosized poly (meta-phenylenediamine) film
    V. M. Pyeshkova
    O. Y. Dudchenko
    O. O. Soldatkin
    S. A. Alekseev
    T. Seker
    B. Akata Kurc
    S. V. Dzyadevych
    Applied Nanoscience, 2022, 12 : 1267 - 1274
  • [30] Strategies for decreasing ascorbate interference at glucose oxidase-modified poly(o-phenylenediamine)-coated electrodes
    McAteer, K
    ONeill, RD
    ANALYST, 1996, 121 (06) : 773 - 777