Plate fixation of extra-articular fractures of the proximal phalanx: do new implants cause less problems?

被引:42
作者
Brei-Thoma, Pascale [1 ]
Voegelin, Esther [1 ]
Franz, Torsten [1 ,2 ]
机构
[1] Inselspital Bern, Dept Plast & Hand Surg, CH-3010 Bern, Switzerland
[2] Uster Hosp, Dept Surg, Hand Surg Serv, Uster, Switzerland
关键词
Fracture; Finger; Proximal phalanx; Internal fixation; Complications; DYNAMIC TREATMENT; HAND; COMPLICATIONS; METACARPAL; REDUCTION; SCREW;
D O I
10.1007/s00402-015-2155-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Limited range of finger motion is a frequent complication after plate fixation of phalangeal fractures. The purpose of this study was to evaluate the results of plate fixation of extra-articular fractures of the proximal phalanx using current low-profile mini-fragment-systems. From 2006 to 2012, 32 patients with 36 extra-articular fractures of the proximal phalanx of the triphalangeal fingers were treated with open reduction and plate fixation (ORPF) using 1.2 and 1.5 mm mini-fragment systems. Patients presenting with open fractures grade 2 and 3 or relevant laceration of adjacent structures were excluded from the study. We retrospectively evaluated the rate of mal-union or non-union after ORPF, the need for revision surgery, for plate removal, and for tenolysis. Data were analyzed for further complications with regard to infections or complex regional pain syndrome (CRPS). No infections were noted. Five patients developed transient symptoms of CRPS. Six weeks postoperatively, total active finger motion (TAM) averaged 183A degrees, and all 32 patients underwent formal hand therapy. At the latest follow-up or at the time of plate removal, respectively, the mean TAM improved to 213A degrees. Extension lag of proximal interphalangeal joints was found in 67 % of all fractured fingers. Secondary surgery was necessary in 14 of 32 patients (2 corrective osteotomies, 12 plate removals including 7 procedures explicitly because of reduced mobility). Despite of new implant designs significant problems persist. Adhesions of extensor tendons leading to limited range of finger motion are still the most frequent complications after ORPF of proximal phalangeal fractures, even in absence of significant soft-tissue damage. Therapeutic, Retrospective, Level IV.
引用
收藏
页码:439 / 445
页数:7
相关论文
共 16 条
[1]   CLOSED REDUCTION AND INTERNAL-FIXATION OF PROXIMAL PHALANGEAL FRACTURES [J].
BELSKY, MR ;
EATON, RG ;
LANE, LB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1984, 9A (05) :725-729
[2]  
BUCHLER U, 1987, CLIN ORTHOP RELAT R, P53
[3]   The frequency and epidemiology of hand and forearm fractures in the United States [J].
Chung, KC ;
Spilson, SV .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (05) :908-915
[4]  
Ebinger T, 1999, J HAND SURG-AM, V24A, P1254
[5]   Results of Dynamic Treatment of Fractures of the Proximal Phalanx of the Hand [J].
Figl, Markus ;
Weninger, Patrick ;
Hofbauer, Marcus ;
Pezzei, Christoph ;
Schauer, Josef ;
Leixnering, Martin .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (04) :852-856
[6]   Extra-Articular Fractures of the Proximal Phalanges of the Fingers: A Comparison of 2 Methods of Functional, Conservative Treatment [J].
Franz, T. ;
von Wartburg, U. ;
Schibli-Beer, S. ;
Jung, F. J. ;
Jandali, A. R. ;
Calcagni, M. ;
Hug, U. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (05) :889-898
[7]  
Freeland Alan E, 2003, J Hand Ther, V16, P129
[8]   Proposed new diagnostic criteria for complex regional pain syndrome [J].
Harden, R. Norman ;
Bruehl, Stephen ;
Stanton-Hicks, Michael ;
Wilson, Peter R. .
PAIN MEDICINE, 2007, 8 (04) :326-331
[9]   Complications after plate fixation of phalangeal fractures [J].
Kurzen, P ;
Fusetti, C ;
Bonaccio, M ;
Nagy, L .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (04) :841-843
[10]   A comparative mechanical analysis of plate fixation in a proximal phalangeal fracture model [J].
Lins, RE ;
Myers, BS ;
Spinner, RJ ;
Levin, LS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (06) :1059-1064