10-year randomized trial (RCT) of zirconia-ceramic and metal-ceramic fixed dental prostheses

被引:91
作者
Sailer, Irena [1 ]
Balmer, Marc [2 ]
Husler, Jurg [2 ]
Hammerle, Christoph Hans Franz [2 ]
Kanel, Sarah [2 ]
Thoma, Daniel Stefan [2 ]
机构
[1] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, 1 Rue Michel Server, CH-1211 Geneva, Switzerland
[2] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Ctr Dent Med, Zurich, Switzerland
关键词
Zirconia; All-ceramics; Metal-ceramic; FDP; Long-term; Technical; Biologic; PARTIAL DENTURES; CLINICAL-TRIAL; RESTORATIVE MATERIALS; FRACTURE STRENGTH; SINGLE CROWNS; INTERNAL FIT; IN-VITRO; Y-TZP; SURVIVAL; PERFORMANCE;
D O I
10.1016/j.jdent.2018.05.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To monitor zirconia-ceramic and metal-ceramic posterior FDPs with respect to survival and technical/biological complication rates. Materials and methods: Fifty-eight patients received 76 3- to 5-unit posterior FDPs. The sites were randomly assigned to 40 zirconia-based (ZC) and 36 metal-based (MC) FDPs. FDPs were examined at baseline (cementation), at 6 months, at 1 year and then yearly up to 10 years. Technical outcomes were assessed using modified United States Public Health Service (USPHS) criteria. Biologic outcomes included probing depth, plaque, bleeding on probing and tooth vitality. Statistical analysis was performed applying Kaplan-Meier (KM) estimation, log-rank, Mann-Whitney and Fisher exact test. Results: During the 10-year follow-up thirteen patients (17 FDPs) dropped out and 6 FDPs in 6 patients (5 ZC,1 MC) were considered catastrophic failures for technical and/or biological reasons. Forty-four patients with 53 FDPs (29 ZC, 24 MC) were available for examination. The median observation period was 10.3 years (ZC) and 10.0 years (MC). The 10-year KM survival estimate of ZC FDPs was 91.3% (95%CI:69.5;97.8) and 100% of MC FDPs. Minor chipping of the veneering ceramic and occlusal wear were found to a similar extent at ZC and MC FDPs. ZC FDPs demonstrated a significantly higher rate of framework fracture, de-bonding, major fractures of the veneering ceramic and poor marginal adaption. Biological outcomes were similar in both groups and between abutment and control teeth. Conclusion: At 10 years, ZC and MC posterior FDPs resulted in similar outcomes for the majority of the outcome measures (p > 0.05).
引用
收藏
页码:32 / 39
页数:8
相关论文
共 34 条
  • [1] Abt E, 2012, COCHRANE DB SYST REV, V2
  • [2] Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial
    Ahrberg, Danush
    Lauer, Hans Christoph
    Ahrberg, Martin
    Weigl, Paul
    [J]. CLINICAL ORAL INVESTIGATIONS, 2016, 20 (02) : 291 - 300
  • [3] Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses
    Anusavice, Kenneth J.
    [J]. DENTAL MATERIALS, 2012, 28 (01) : 102 - 111
  • [4] Bahat Z, 2009, SWED DENT J, V33, P149
  • [5] Reprinting the classic article on USPHS evaluation methods for measuring the clinical research performance of restorative materials
    Bayne, SC
    Schmalz, G
    [J]. CLINICAL ORAL INVESTIGATIONS, 2005, 9 (04) : 209 - 214
  • [6] Risk of chipping or facings failure of metal ceramic fixed partial prostheses-a retrospective data record analysis
    Behr, Michael
    Winklhofer, Christina
    Schreier, Maria
    Zeman, Florian
    Kobeck, Carola
    Braeuer, Isabel
    Rosentritt, Martin
    [J]. CLINICAL ORAL INVESTIGATIONS, 2012, 16 (02) : 401 - 405
  • [7] Effect of preparation angles on the precision of zirconia crown copings fabricated by CAD/CAM system
    Beuer, Florian
    Edelhoff, Daniel
    Gernet, Wolfgang
    Naumann, Michael
    [J]. DENTAL MATERIALS JOURNAL, 2008, 27 (06) : 814 - 820
  • [8] The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems
    Brawek, Petya K.
    Wolfart, Stefan
    Endres, Lutz
    Kirsten, Armin
    Reich, Sven
    [J]. CLINICAL ORAL INVESTIGATIONS, 2013, 17 (09) : 2119 - 2125
  • [9] Marginal and internal fit of curved anterior CAD/CAM-milled zirconia fixed dental prostheses: An in-vitro study
    Buechi, Dominik L.
    Ebler, Sabine
    Haemmerle, Christoph H. F.
    Sailer, Irena
    [J]. QUINTESSENCE INTERNATIONAL, 2014, 45 (10): : 837 - 846
  • [10] Ten-year clinical outcome of three-unit posterior FDPs made from a glass-infiltrated zirconia reinforced alumina ceramic (In-Ceram Zirconia)
    Chaar, M. Sad
    Passia, Nicole
    Kern, Matthias
    [J]. JOURNAL OF DENTISTRY, 2015, 43 (05) : 512 - 517