Edge Vascular Response After Polymer-Free vs. Polymer-Based Paclitaxel-Eluting Stent Implantation - Serial Intravascular Ultrasound Study From the Late Incomplete Stent Apposition Evaluation (LISA) Trial

被引:1
|
作者
Otsuki, Shuji [1 ]
Shiratori, Yoshitaka [1 ]
Brugaletta, Salvatore [1 ]
Cola, Clarissa [2 ]
Garcia del Blanco, Bruno [3 ]
Ruiz-Salmeron, Rafael [4 ]
Francisco Diaz, Jose [5 ]
Pinar, Eduardo [6 ]
Marti, Vicens [2 ]
Garcia-Picart, Juan [2 ]
Martin-Yuste, Victoria [1 ]
Sabate, Manel [1 ]
机构
[1] Univ Barcelona, Dept Cardiol, Hosp Clin, IDIBAPS, Barcelona, Spain
[2] St Pau Hosp, Dept Cardiol, Barcelona, Spain
[3] Vall dHebron Hosp, Dept Cardiol, Barcelona, Spain
[4] Virgen de Macarena Hosp, Dept Cardiol, Seville, Spain
[5] Juan Ramon Jimenez Hosp, Dept Cardiol, Huelva, Spain
[6] Virgen de la Arrixaca Hosp, Dept Cardiol, Murcia, Spain
关键词
Drug-eluting stent; Edge vascular response; Intravascular ultrasound; Polymer-based paclitaxel-eluting stent; Polymer-free paclitaxel-eluting stent; CORONARY-ARTERY LESIONS; RANDOMIZED-TRIAL; CLINICAL-TRIAL; DIABETIC-PATIENTS; SLOW-RELEASE; FOLLOW-UP; TAXUS-IV; REVASCULARIZATION; HYPERPLASIA; IMPACT;
D O I
10.1253/circj.CJ-14-0345
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). Methods and Results: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1: 1 to receive either PF-PES or PB-PES. Those patients with paired intravascular ultrasound (IVUS) after procedure and at 9-month follow-up were included in this analysis. Seventy-six patients with 84 lesions, divided into PB-PES (38 patients, 41 lesions) and PF-PES groups (38 patients, 43 lesions) had paired post-procedure and 9-month follow-up IVUS and were therefore included in this substudy. There was a significant lumen decrease at the proximal edge of PF-PES (from 9.02 +/- 3.06 mm(2) to 8.47 +/- 3.05 mm(2); P=0.040), and a significant plaque increase at the distal edges of PF-PES (from 4.39 +/- 2.73 mm(2) to 4.78 +/- 2.63 mm(2); P=0.004). At the distal edge there was a significant plaque increase in the PF-PES compared to PB-PES (+8.0% vs. -0.6%, respectively; P=0.015) with subsequent lumen reduction (-5.2% vs. +6.0%, respectively; P=0.024). Conclusions: PF-PES had significant plaque increase and lumen reduction at the distal edge as compared to PB-PES, probably due to difference in polymer-based drug-release kinetics between the 2 platforms.
引用
收藏
页码:2657 / 2664
页数:8
相关论文
共 11 条
  • [1] Comparison of a polymer-free rapamycin-eluting stent (YUKON) with a polymer-based paclitaxel-eluting stent (TAXUS) in real-world coronary artery lesions
    Ruef, Johannes
    Stroeger, Hans
    Schwarz, Franz
    Haase, Juergen
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 71 (03) : 333 - 339
  • [2] Comparison of vascular response to the everolimus-eluting stent versus the paclitaxel-eluting stent: intravascular ultrasound results from the SPIRIT III trial
    Yamasaki, Masao
    Tsujino, Ichizo
    Lima-Filho, Moyses O.
    Ako, Junya
    Shimohama, Takao
    Hasegawa, Takao
    Sakurai, Ryota
    Sudhir, Krishnankutty
    Stone, Gregg W.
    Waseda, Katsuhisa
    Honda, Yasuhiro
    Fitzgerald, Peter J.
    EUROINTERVENTION, 2012, 8 (06) : 724 - 731
  • [3] Randomized Comparison Between Polymer-Free Versus Polymer-Based Paclitaxel-Eluting Stent Two-Year Final Clinical Results
    Shiratori, Yoshitaka
    Cola, Clarissa
    Brugaletta, Salvatore
    Alvarez-Contreras, Luis
    Martin-Yuste, Victoria
    Garcia del Blanco, Bruno
    Ruiz-Salmeron, Rafael
    Diaz, Jose
    Pinar, Eduardo
    Marti, Vicens
    Garcia-Picart, Juan
    Sabate, Manel
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (03) : 312 - 321
  • [4] A novel polymer-free paclitaxel-eluting stent with a nanoporous surface for rapid endothelialization and inhibition of intimal hyperplasia: Comparison with a polymer-based sirolimus-eluting stent and bare metal stent in a porcine model
    Jia, Haibo
    Liu, Haixia
    Kong, Junying
    Hou, Jingbo
    Wu, Jian
    Zhang, Maomao
    Tian, Jinwei
    Liu, Huimin
    Ma, Lijia
    Hu, Sining
    Huang, Xingtao
    Zhang, Shaosong
    Zhang, Shuo
    Yu, Bo
    Jang, Ik-Kyung
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2011, 98A (04) : 629 - 637
  • [5] Effect of preinterventional arterial remodeling on intimal hyperplasia after implantation of a polymer-based paclitaxel-eluting stent: Angiographic and IVUS study
    Kang, Woong Chol
    Oh, Kyu Jin
    Han, Seung Hwan
    Ahn, Tae Hoon
    Chung, Wook-Jin
    Shin, Mi-Seung
    Koh, Kwang Kon
    Choi, In Suck
    Shin, Eak Kyun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 123 (01) : 50 - 54
  • [6] Five-Year Clinical Follow-Up of a Randomized Comparison of a Polymer-Free Sirolimus-Eluting Stent versus a Polymer-Based Paclitaxel-Eluting Stent in Patients with Diabetes Mellitus (LIPSIA Yukon Trial)
    Stiermaier, Thomas
    Heinz, Anja
    Schloma, Denis
    Kleinertz, Klaus
    Daenschel, Wilfried
    Erbs, Sandra
    Linke, Axel
    Boudriot, Enno
    Lauer, Bernward
    Schuler, Gerhard
    Thiele, Holger
    Desch, Steffen
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (03) : 418 - 424
  • [7] Impact of Positive Peri-Stent Vascular Remodeling After Sirolimus-Eluting and Paclitaxel-Eluting Stent Implantation on 5-Year Clinical Outcomes - Intravascular Ultrasound Analysis From the Poststent Optimal Stent Expansion Trial Multicenter Randomized Trial
    Kang, Ki-Woon
    Ko, Young-Guk
    Shin, Dong-Ho
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Choi, Donghoon
    Hong, Myeong-Ki
    Kang, Woong Chol
    Ahn, Taehoon
    Jeon, Dong Woon
    Yang, Joo-Young
    Jang, Yangsoo
    CIRCULATION JOURNAL, 2012, 76 (05) : 1102 - 1108
  • [8] Impact of preinterventional arterial remodeling on neointimal hyperplasia after implantation of (non-polymer-encapsulated) paclitaxel-coated stents - A serial volumetric intravascular ultrasound analysis from the ASian Paclitaxel-Eluting Stent Clinical Trial (ASPECT)
    Mintz, GS
    Tinana, A
    Hong, MK
    Lee, CW
    Kim, JJ
    Fearnot, NE
    Park, SW
    Park, SJ
    Weissman, NJ
    CIRCULATION, 2003, 108 (11) : 1295 - 1298
  • [9] Serial Evaluation of Vascular Response After Implantation of a New Sirolimus-Eluting Stent With Bioabsorbable Polymer (MISTENT): An Optical Coherence Tomography and Histopathological Study
    Attizzani, Guilherme F.
    Bezerra, Hiram G.
    Chamie, Daniel
    Fujino, Yusuke
    Spognardi, Anna-Maria
    Stanley, James R. L.
    Yamamoto, Hirosada
    Mehanna, Emile
    Wang, Wei
    Carlyle, Wenda C.
    McClain, James B.
    Costa, Marco A.
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (11) : 560 - 568
  • [10] Vascular response to paclitaxel-eluting nitinol self-expanding stent in superficial femoral artery lesions: post-implantation angioscopic findings from the SHIMEJI trial (Suppression of vascular wall Healing after IMplantation of drug Eluting peripheral stent in Japanese patients with the Infra inguinal lesion: serial angioscopic observation)
    Tsukiyama, Yoshiro
    Shinke, Toshiro
    Ishihara, Takayuki
    Otake, Hiromasa
    Terashita, Daisuke
    Kozuki, Amane
    Fukunaga, Masashi
    Zen, Kan
    Horimatsu, Tetsuo
    Fujii, Kenichi
    Shite, Junya
    Uematsu, Masaaki
    Takahara, Mitsuyoshi
    Iida, Osamu
    Nanto, Shinsuke
    Hirata, Ken-ichi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (10) : 1777 - 1784