Comparison of 90° and epi-geometry for two-photon excitation in capillaries

被引:2
作者
Zugel, SA [1 ]
Lytle, FE [1 ]
机构
[1] Purdue Univ, Dept Chem, Brown Lab 1393, W Lafayette, IN 47907 USA
关键词
fluorescence; two-photon; capillary; epi-fluorescence; time filtering;
D O I
10.1366/0003702001948402
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two geometries of excitation/emission optics are compared for two-photon excitation of time-resolved fluorescence in capillaries. The test fluorophore is the enzymatic tag beta -naphthylamine (BNA). Two 0.25 NA (numerical aperture) microscope objectives are used in the 90 degrees geometry: This configuration has a sensitivity of 1.9 x 10(10) count M-1 min(-1) and a detection limit of 2.5 nM [signal-to-noise (S/N) = 3]. The epi-geometry uses single objectives of 0.25, 0.50, or 1.25 NA. This second configuration has a sensitivity of 7.6 x 10(10) count M-1 min(-1) and a detection limit of 1.7 nM (S/N = 3) for the 1.25 NA objective. The similar performance of the two configurations is in stark contrast to the factor of 46 enhancement predicted by geometric optics for epi-excitation. The discrepancy is attributed to large increases in collected background counts, which make detection of the signal difficult.
引用
收藏
页码:1490 / 1494
页数:5
相关论文
共 16 条
[1]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[2]   Source-corrected two-photon excited fluorescence measurements between 700 and 880 nm [J].
Fisher, WG ;
Wachter, EA ;
Lytle, FE ;
Armas, M ;
Seaton, C .
APPLIED SPECTROSCOPY, 1998, 52 (04) :536-545
[3]  
Gauderon R, 1999, MICROSC RES TECHNIQ, V47, P210, DOI 10.1002/(SICI)1097-0029(19991101)47:3<210::AID-JEMT7>3.0.CO
[4]  
2-H
[5]   Single-molecule detection by two-photon-excited fluorescence [J].
Mertz, J ;
Xu, C ;
Webb, WW .
OPTICS LETTERS, 1995, 20 (24) :2532-2534
[6]   Optimization of confocal epifluorescence microscopy for microchip-based miniaturized total analysis systems [J].
Ocvirk, G ;
Tang, T ;
Harrison, DJ .
ANALYST, 1998, 123 (07) :1429-1434
[7]   Blank-free two-photon excited fluorescence detection [J].
Overway, KS ;
Duhachek, SD ;
LoeffelMann, K ;
Zugel, SA ;
Lytle, FE .
APPLIED SPECTROSCOPY, 1996, 50 (10) :1335-1337
[8]   Two-photon excitation profiles in cylindrical capillaries [J].
Overway, KS ;
Lytle, FE .
APPLIED SPECTROSCOPY, 1998, 52 (07) :928-932
[9]   Fluorescent enzymatic probes suitable for two-photon excitation [J].
Overway, KS ;
Lytle, FE .
APPLIED SPECTROSCOPY, 1998, 52 (02) :298-302
[10]   OPTIMIZATION OF SIGNAL-TO-NOISE RATIOS IN TIME-FILTERED FLUORESCENCE DETECTION [J].
SEITZINGER, NK ;
HUGHES, KD ;
LYTLE, FE .
ANALYTICAL CHEMISTRY, 1989, 61 (23) :2611-2615