Ultrasonic transducer with BiScO3-PbTiO3-based ceramics of operating temperature over 400°C

被引:16
作者
Dong, Yazhu [1 ,2 ]
Yue, Qingwen [1 ]
Cheng, Dongxu [1 ,2 ]
Zhou, Zhiyong [1 ]
Liang, Ruihong [1 ]
Dong, Xianlin [1 ,3 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Ceram, Key Lab Inorgan Funct Mat & Devices, 1295 Dingxi Rd, Shanghai 200050, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Shanghai Inst Ceram, State Key Lab High Performance Ceram & Superfine M, Shanghai 200050, Peoples R China
基金
中国国家自然科学基金;
关键词
Ultrasonic transducer; BiScO3-PbTiO3-based; Temperature stability;
D O I
10.1016/j.sna.2022.113528
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Ultrasonic transducers are widely employed in many fields such as non-destructive testing (NDT), petrochemical refineries, aerospace field, etc., in which high temperature ultrasonic transducers are necessary because many measurements must be done at elevated temperature. In this work, 4.5 MHz high temperature ultrasonic transducers with delay line were designed and fabricated based on BiScO3-Pb(Ti0.99Zn0.01)O-3 (BS-0.01PZnT) piezoelectric ceramics possessing excellent temperature stability and high Curie temperature. The experimental results revealed that-6 dB bandwidth and the center frequency of high temperature ultrasonic transducers are around 129% and 4.5 MHz, respectively, which are almost stable from room temperature to 400 degrees C. The peak-to peak values (V-pp) is as large as 1.5 V at RT, indicating very high sensitivity. More importantly, the ultrasonic transducers with customized BS-0.01PZnT ceramics can work reliably at high temperature of 380 degrees C and 450 degrees C by in-situ measurement at elevated temperatures. This work verifies the great potential application values of ultrasonic transducers with BS-0.01PZnT ceramics in high temperature applications.
引用
收藏
页数:8
相关论文
共 33 条
  • [1] [Anonymous], 2020, Materials technical data (typical values)
  • [2] High-Temperature (>500°C) Wall Thickness Monitoring Using Dry-Coupled Ultrasonic Waveguide Transducers
    Cegla, Frederic B.
    Cawley, Peter
    Allin, Jonathan
    Davies, Jacob
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (01) : 156 - 167
  • [3] Chang Fu-Kuo., 1998, Structural health monitoring: current status and perspectives
  • [4] Zero thermal expansion in PbTiO3-Based perovskites
    Chen, Jun
    Xing, Xianran
    Sun, Ce
    Hu, Penghao
    Yu, Ranbo
    Wang, Xiaowei
    Li, Lihong
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (04) : 1144 - +
  • [5] High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility
    Cheong, Yong-Moo
    Kim, Kyung-Mo
    Kim, Dong-Jin
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (07) : 1463 - 1471
  • [6] Structural investigations of the bismuth scandate-lead titanate xBiScO3-(1-x) PbTiO3 solid solution for 0.10≤x≤ 0.40
    Datta, K.
    Walker, D.
    Thomas, P. A.
    [J]. PHYSICAL REVIEW B, 2010, 82 (14)
  • [7] Excellent piezoelectric constant and thermal stability in BiScO3-PbTiO3 piezoelectric ceramics via domain engineering
    Dong, Yazhu
    Zhou, Zhiyong
    Liang, Ruihong
    Dong, Xianlin
    [J]. JOURNAL OF MATERIOMICS, 2022, 8 (02) : 319 - 326
  • [8] Investigation into the phase structures and temperature stability of BiScO3-PbTiO3-based piezoelectric ceramics
    Dong, Yazhu
    Zhou, Zhiyong
    Liang, Ruihong
    Dong, Xianlin
    [J]. JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2022, 105 (02) : 1558 - 1567
  • [9] Ehite E.H, 2008, EXPT INVESTIGATION E
  • [10] Tailoring properties and performance of (1-x)BiScO3-xPbTiO3 based piezoceramics by lanthanum substitution
    Eitel, RE
    Shrout, TR
    Randall, CA
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2004, 43 (12): : 8146 - 8150