Time-alignment of bidimensional chromatograms in the presence of uncalibrated interferences using parallel factor analysis Application to multi-component determinations using liquid-chromatography with spectrofluorimetric detection

被引:39
作者
Bortolato, S. A.
Arancibia, J. A.
Escandar, G. M.
Olivieri, A. C. [1 ]
机构
[1] Univ Nacl Rosario, Dept Quim Analit, Fac Ciencias Bioquim & Farmaceut, RA-2000 Rosario, Santa Fe, Argentina
关键词
Chromatographic-spectral matrices; Time alignment; Parallel factor analysis; Partial least-squares; Residual bilinearization; TRILINEAR DECOMPOSITION ALGORITHM; PARTIAL LEAST-SQUARES; 2ND-ORDER CALIBRATION; MULTIVARIATE CALIBRATION; BILINEARIZATION; QUANTIFICATION; CHEMOMETRICS; REGRESSION; ADVANTAGE; PRECISION;
D O I
10.1016/j.chemolab.2009.12.001
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A new methodology for the alignment of matrix chromatographic data is proposed, based on the decomposition of a three-way array composed of a test and a reference data matrix using a suitably initialized and constrained parallel factor (PARAFAC) model. It allows one to perform matrix alignment when the test data matrix contains unexpected chemical interferences, in contrast to most of the available algorithms. A series of simulated analytical systems is studied, as well as an experimental one, all having calibrated analytes and also potential interferences in the test samples, i.e., requiring the second-order advantage for successful analyte quantitation. The results show that the newly proposed method is able to properly align the different data matrix, restoring the trilinearity which is required to process the calibration and test data with second-order multivariate calibration algorithms such as PARAFAC. Recent models including unfolded partial least-squares regression (U-PLS) and N-dimensional PLS (N-PLS), combined with residual bilinearization (RBL), are also applied to both simulated and experimental data. The latter one corresponds to the determination of the polycyclic aromatic hydrocarbons benzo[b]fluoranthene and benzo [k]fluoranthene in the presence of benzo[j]fluoranthene as interference. The analytical figures of merit provided by the second-order calibration models are compared and discussed. (C) 2009 Elsevier FIN. All rights reserved.
引用
收藏
页码:30 / 37
页数:8
相关论文
共 49 条