Corrosion detection of steel reinforced concrete using combined carbon fiber and fiber Bragg grating active thermal probe

被引:34
作者
Li, Weijie [1 ,2 ]
Ho, Siu Chun Michael [1 ]
Song, Gangbing [1 ,2 ]
机构
[1] Univ Houston, Dept Mech Engn, Houston, TX 77204 USA
[2] Dalian Univ Technol, Sch Civil Engn, Dalian 116023, Liaoning, Peoples R China
关键词
reinforcement corrosion; reinforced concrete; fiber Bragg grating; active thermal probe; carbon fiber;
D O I
10.1088/0964-1726/25/4/045017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Steel reinforcement corrosion is one of the dominant causes for structural deterioration for reinforced concrete structures. This paper presents a novel corrosion detection technique using an active thermal probe. The technique takes advantage of the fact that corrosion products have poor thermal conductivity, which will impede heat propagation generated from the active thermal probe. At the same time, the active thermal probe records the temperature response. The presence of corrosion products can thus be detected by analyzing the temperature response after the injection of heat at the reinforcement-concrete interface. The feasibility of the proposed technique was firstly analyzed through analytical modeling and finite element simulation. The active thermal probe consisted of carbon fiber strands to generate heat and a fiber optic Bragg grating (FBG) temperature sensor. Carbon fiber strands are used due to their corrosion resistance. Wet-dry cycle accelerated corrosion experiments were performed to study the effect of corrosion products on the temperature response of the reinforced concrete sample. Results suggest a high correlation between corrosion severity and magnitude of the temperature response. The technique has the merits of high accuracy, high efficiency in measurement and excellent embeddability.
引用
收藏
页数:9
相关论文
共 25 条
[1]   Combined use of thermography and ultrasound for the characterization of subsurface cracks in concrete [J].
Aggelis, D. G. ;
Kordatos, E. Z. ;
Soulioti, D. V. ;
Matikas, T. E. .
CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (10) :1888-1897
[2]   Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method [J].
Andrade, C ;
Alonso, C ;
Gulikers, J ;
Polder, R ;
Cigna, R ;
Vennesland, O ;
Salta, M ;
Raharinaivo, A ;
Elsener, B .
MATERIALS AND STRUCTURES, 2004, 37 (273) :623-643
[3]   Measurement of thermal properties and water content of unsaturated sandy soil using dual-probe heat-pulse probes [J].
Bristow, KL .
AGRICULTURAL AND FOREST METEOROLOGY, 1998, 89 (02) :75-84
[4]  
Broomfield J., 2002, CONCRETE, V36
[5]  
Brown T.D., 1970, MAT RIAUX CONSTRUCTI, V3, P411, DOI [10.1007/bf02478765, DOI 10.1007/BF02478765]
[6]  
Carslaw H.S., 1959, Conduction of heat in solids, V2d, P1
[7]   A feasibility study of self-heating concrete utilizing carbon nanofiber heating elements [J].
Chang, Christiana ;
Ho, Michelle ;
Song, Gangbing ;
Mo, Yi-Lung ;
Li, Hui .
SMART MATERIALS AND STRUCTURES, 2009, 18 (12)
[8]   A NONSTATIONARY METHOD FOR DETERMINING THERMAL CONDUCTIVITY OF SOIL INSITU [J].
DEVRIES, DA .
SOIL SCIENCE, 1952, 73 (02) :83-89
[9]  
Grattan S, 2007, J PHYS C SER
[10]   ERROR ANALYSIS OF THE HEAT PULSE METHOD FOR MEASURING SOIL VOLUMETRIC HEAT-CAPACITY [J].
KLUITENBERG, GJ ;
HAM, JM ;
BRISTOW, KL .
SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1993, 57 (06) :1444-1451