Evaluation of the i-STAT Alinity v in a veterinary clinical setting

被引:4
作者
Burke, Jasper E. [1 ]
Nguyen, Thuy Hien T. [2 ]
Davis, Tanya [2 ]
Koenig, Amie [1 ]
Lane, Selena L. [1 ]
Good, Jennifer [1 ]
Brainard, Benjamin M. [1 ]
机构
[1] Univ Georgia, Coll Vet Med, Dept Small Anim Med & Surg, Athens, GA USA
[2] Zoetis Inc, Parsippany, NJ USA
关键词
blood gas; cats; dogs; electrolytes; emergency; point-of-care; BLOOD-GASES; ANALYZER; PH; ELECTROLYTES; GUIDELINES; ACCURACY;
D O I
10.1177/10406387211019710
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Many point-of-care (POC) analyzers are available for the measurement of electrolytes and acid-base status in animals. We assessed the precision of the i-STAT Alinity v, a recently introduced POC analyzer, and compared it to 2 commonly used and previously validated POC analyzers (i-STAT 1, Stat Profile pHOx Ultra). Precision was evaluated by performing multiple analyses of whole blood samples from healthy dogs, cats, and horses on multiple i-STAT Alinity v analyzers. For comparison between analyzers, whole blood samples from dogs and cats presented to the emergency room were run concurrently on all 3 POC instruments. Reported values were compared by species (dogs and cats only) using Pearson correlation, and all values from all species were analyzed together for the Bland-Altman analysis. Results suggested that the i-STAT Alinity v precision was very good, with median coefficients of variability <2.5% for all measured parameters (except the anion gap), with variable ranges of coefficients of variation. In addition, good-to-excellent correlation was observed between the i-STAT Alinity v and i-STAT 1, and between the i-STAT Alinity v and Stat Profile pHOx Ultra for all parameters in both cats and dogs, respectively. In this cohort, the i-STAT Alinity v had clinically acceptable bias compared to the currently marketed analyzers and can be used for monitoring measured analytes in cats and dogs, although serial measurements in a single animal should be performed on the same analyzer whenever possible.
引用
收藏
页码:703 / 710
页数:8
相关论文
共 50 条
  • [31] Evaluation of the i-STAT point-of-care capillary whole blood prothrombin time and international normalized ratio: Comparison to the Tcoag MDAII coagulation analyzer in the central laboratory
    Pena, J. A.
    Lewandrowski, K. B.
    Lewandrowski, E. L.
    Gregory, K.
    Baron, J. M.
    Van Cott, E. M.
    [J]. CLINICA CHIMICA ACTA, 2012, 413 (11-12) : 955 - 959
  • [32] Accuracy and reliability of the i-STAT point-of-care device for the determination of haemoglobin concentration before and after major blood loss
    Ng, W. L.
    Short, T. G.
    Gunn, K. N.
    Fuge, G. S.
    Slon, B.
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2014, 42 (04) : 495 - 499
  • [33] Comparison of point-of-care testing (POCT): i-STAT® international normalized ratio (INR) vs reference laboratory INR in pediatric patients undergoing major surgery
    Spielmann, Nelly
    Mauch, Jacqueline Y.
    Madjdpour, Caveh
    Schmugge, Markus
    Albisetti, Manuela
    Weiss, Markus
    Haas, Thorsten
    [J]. PEDIATRIC ANESTHESIA, 2011, 21 (10) : 1041 - 1045
  • [34] Clinical and Analytical Evaluation of the Alinity m HR HPV Assay within the VALGENT-3 Framework
    Dhillon, Sharonjit K.
    Valencak, Anja Ostrbenk
    Xu, Lan
    Poljak, Mario
    Arbyn, Marc
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (06)
  • [35] Evaluation of the i-STAT point-of-care capillary whole blood hematocrit and hemoglobin: Comparison to the Siemens RAPIDLab 1200, Sysmex XE5000, and manual spun hematocrit
    Rudolf, Joseph
    Douglass, Joseph
    Baron, Jason
    Lewandrowski, Kent
    [J]. CLINICA CHIMICA ACTA, 2015, 446 : 37 - 42
  • [36] Comparison of the clinical and analytical performance of Alinity m HR HPV and cobas 4800 HPV assays in a population-based screening setting
    Valencak, Anja Ostrbenk
    Bertram, Alexander
    Groning, Arndt
    Poljak, Mario
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2021, 140
  • [37] Accuracy of capillary whole blood international normalized ratio on the CoaguChek S, CoaguChek XS, and i-STAT 1 point-of-care analyzers
    Karon, Brad S.
    McBane, Robert D., II
    Chaudhry, Rajeev
    Beyer, Lisa K.
    Santrach, Paula J.
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 130 (01) : 88 - 92
  • [38] Development and Evaluation of a Canine Laparoscopic Simulator for Veterinary Clinical Training
    Uson-Gargallo, Jesus
    Tapia-Araya, Angelo E.
    Diaz-Gueemes Martin-Portugues, Idoia
    Sanchez-Margallo, Francisco M.
    [J]. JOURNAL OF VETERINARY MEDICAL EDUCATION, 2014, 41 (03) : 218 - 224
  • [39] Evaluation of the analytical performances of the Alinity-i HSV-1 IgG and HSV-2 IgG chemiluminescent immunoassays
    Bourdin, Joachim
    Salmona, Maud
    Fidouh, Nadhira
    Fouere, Sebastien
    Legoff, Jerome
    Maylin, Sarah
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2025, 177
  • [40] Interoceptive awareness in a clinical setting: the need to bring interoceptive perspectives into clinical evaluation
    Duran, Paola Solano
    Morales, Juan-Pablo
    Huepe, David
    [J]. FRONTIERS IN PSYCHOLOGY, 2024, 15