Clinical Evaluation of the Intraoperative Refraction Technique for Intraocular Lens Power Calculation

被引:11
|
作者
Wong, Albert Chak Ming [1 ]
Mak, Shiu Ting [1 ]
Tse, Raymond Kwok Kay [1 ]
机构
[1] Caritas Med Ctr, Dept Ophthalmol, Kowloon, Hong Kong, Peoples R China
关键词
HAND-HELD AUTOREFRACTOR; CORNEAL POWER; SURGERY; CHILDREN; ACCURACY; ERRORS; MYOPIA;
D O I
10.1016/j.ophtha.2009.09.004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate clinically the intraoperative refraction technique for intraocular lens (IOL) power calculation using 2 existing formulas proposed by Ianchulev and Leccisotti and to derive alternative formulas for this technique. Design: Comparative case series. Participants: One hundred eighty-two eyes from 182 patients with cataract. Methods: Recruited patients were separated into a normal cornea group and a special group that included eyes with surgically altered corneas. Phacoemulsification was carried out for all cases. Intraoperative aphakic autorefraction using a portable autorefractor was performed. An IOL with power calculated before surgery then was implanted. In each eye, postoperative refraction was obtained. The IOL power that would have achieved emmetropia was calculated retrospectively. Aphakic autorefraction readings obtained during surgery were used to calculate the aphakic spherical equivalent (SE). The 2 formulas incorporating aphakic SE were applied to calculate the target IOL power. Comparison then was made to determine the accuracy of the formulas. Main Outcome Measures: A difference (referred to as IOL difference) was calculated by subtracting the adjusted emmetropic IOL power determined by postoperative refraction from the emmetropic IOL power calculated by the 2 formulas using intraoperative aphakic SE. Results: One hundred forty-four patients were in the normal cornea group and 18 were in the special group. In the normal group, the Ianchulev formula showed a relatively accurate prediction for IOL power to achieve emmetropia over almost the full range of axial length except in extremely long eyes. The Leccisotti formula tended to overestimate IOL power and worked particularly poorly in short eyes. It worked best in long eyes. In the special group, neither of the 2 formulas was able to show superiority universally. Using data from the normal group, alternative formulas for IOL power calculation were derived. These new formulas then were validated on the special group that showed good estimation. Conclusions: The Ianchulev formula could be applied to most eyes, with the exception of those in highly myopic subjects. The Leccisotti formula showed good performance in myopic patients. For eyes falling into the special group, an alternative formula, correction factor, or both, may be required. The new formulas reported herein may be an option. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. Ophthalmology 2010;117:711-716 (C) 2010 by the American Academy of Ophthalmology.
引用
收藏
页码:711 / 716
页数:6
相关论文
共 50 条
  • [1] Intraoperative refraction for intraocular lens power calculation
    Biancardi, Ana Luiza
    Walsh, Aileen
    Crema, Armando Stefano
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2011, 70 (02) : 118 - 121
  • [2] Intraocular lens power calculation after laser situ keratomileusis: Aphakic refraction technique
    Mackool, RJ
    Ko, W
    Mackool, R
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03): : 435 - 437
  • [3] Intraoperative Aberrometry and Intraocular Lens Power Calculation Reply
    Hatch, Kathryn M.
    Woodcock, Emily
    Talamo, Jonathan H.
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (02) : 138 - +
  • [4] Intraocular lens power calculation using intraoperative retinoscopy
    Happe, W
    Wiechens, B
    Haigis, W
    Behrendt, S
    Duncker, G
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1997, 210 (04) : 207 - 212
  • [5] Intraoperative aphakic refraction as an adjunct for intraocular lens power calculation in post-corneal refractive surgery
    Umesh, Y.
    Bhat, Shruti
    Balasubramaniam, Anand
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (10) : 2888 - +
  • [6] THE SELECTION OF INTRAOCULAR-LENS POWER BY CALCULATION AND BY REFERENCE TO THE REFRACTION - A CLINICAL-STUDY
    HILLMAN, JS
    TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1982, 102 : 495 - 497
  • [7] Theoretical evaluation of the cataract extraction-refraction-implantation techniques for intraocular lens power calculation
    Sheppard, Amy L.
    Dunne, Mark C. M.
    Wolffsohn, James S.
    Davies, Leon N.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2008, 28 (06) : 568 - 576
  • [8] Triple procedure; analysis of outcome, refraction, and intraocular lens power calculation
    Geerards, AJM
    Hassmann, E
    Beekhuis, WH
    Remeyer, L
    vanRij, G
    Rijneveld, WJ
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1997, 81 (09) : 774 - 777
  • [9] THE TRIPLE PROCEDURE - ANALYSIS OF OUTCOME, REFRACTION, AND INTRAOCULAR-LENS POWER CALCULATION
    CRAWFORD, GJ
    STULTING, RD
    WARING, GO
    VANMETER, WS
    WILSON, LA
    OPHTHALMOLOGY, 1986, 93 (06) : 817 - 824
  • [10] Intraocular lens power calculation
    Olsen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2176 - 2177