Electrochemical Oxidation and Detection of Morphine at Ordered Mesoporous Carbon Modified Glassy Carbon Electrodes

被引:16
|
作者
Bo, Xiangjie [1 ]
Xie, Wenlin [2 ]
Ndamanisha, Jean Chrysostome [1 ]
Bai, Jing [1 ]
Guo, Liping [1 ]
机构
[1] NE Normal Univ, Fac Chem, Changchun 130024, Peoples R China
[2] Evidence Identificat Ctr, Jilin Prov Publ Secur Dept, Changchun 130051, Peoples R China
关键词
Ordered mesoporous carbon; Electrocatalysis; Morphine; Amperometric determination; AMPEROMETRIC DETECTION; ELECTROCATALYTIC OXIDATION; LIQUID-CHROMATOGRAPHY; HUMAN URINE; RAT-BRAIN; INJECTION; CODEINE; BEHAVIOR;
D O I
10.1002/elan.200900265
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, three ordered mesoporous carbons (OMCs) with different structural parameters were synthesized by a simple variation of the hydrothermal temperature of the silica templates (SBA-15). X-ray diffraction and nitrogen adsorption-desorption results show these OMCs exhibit an ordered 2D hexagonal mesostructure with tunable pore diameter. OMC-modified glassy carbon electrodes exhibit efficient electrocatalytic reactivity toward oxidation of morphine (MO). The amperometric detection of MO in pH 7.0 phosphate buffered saline at +0.39 V versus Ag/AgCl is the lowest potential reported to-date. A linear range from 0.2 to 197.6 mu M and a detection limit of 0.03 mu M MO were obtained.
引用
收藏
页码:2549 / 2555
页数:7
相关论文
共 50 条
  • [41] Modified glassy carbon electrodes based on carbon nanostructures for ultrasensitive electrochemical determination of furazolidone
    Shahrokhian, Saeed
    Naderi, Leila
    Ghalkhani, Masoumeh
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 61 : 842 - 850
  • [42] A Flow Injection Amperometric Sensor for Nitrate Detection Based on Cu Foam/Ordered Mesoporous Carbon Modified Glassy Carbon Electrode
    Junlapak, Nuttakorn
    Numnuam, Apon
    Nontipichet, Natha
    Kangkamano, Tawatchai
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Khumngern, Suntisak
    CHEMNANOMAT, 2024, 10 (06)
  • [43] Amperometric detection of morphine at preheated glassy carbon electrode modified with multiwall carbon nanotubes
    Salimi, A
    Hallaj, R
    Khayatian, GR
    ELECTROANALYSIS, 2005, 17 (10) : 873 - 879
  • [44] Immobilization of Nafion-ordered mesoporous carbon on a glassy carbon electrode: Application to the detection of epinephrine
    Zhou, Ming
    Guo, Li-Ping
    Hou, Ying
    Peng, Xiao-Juan
    ELECTROCHIMICA ACTA, 2008, 53 (12) : 4176 - 4184
  • [45] Electrochemical oxidation of benzaldehyde and hydroxybenzaldehydes in acetonitrile on platinum and glassy carbon electrodes
    Kiss, Laszlo
    Kunsagi-Mate, Sandor
    COMPTES RENDUS CHIMIE, 2019, 22 (08) : 557 - 561
  • [46] ELECTROCHEMICAL STUDY OF THE OXIDATION OF TIN(II) AT GLASSY-CARBON ELECTRODES
    KIEKENS, P
    VERPLAETSE, H
    TEMMERMAN, E
    TALANTA, 1981, 28 (03) : 192 - 194
  • [47] Polyphenol-modified glassy carbon electrodes for copper detection
    Oztekin, Yasemin
    Yazicigil, Zafer
    Ramanaviciene, Almira
    Ramanavicius, Arunas
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 152 (01): : 37 - 48
  • [48] Carbon-nanotube-modified glassy carbon electrodes for amplified label-free electrochemical detection of DNA hybridization
    Wang, J
    Kawde, AN
    Musameh, M
    ANALYST, 2003, 128 (07) : 912 - 916
  • [49] Electrochemical Determination of Omeprazole at Molybdenum Disulfide Modified Glassy Carbon Electrodes
    Khanfar, Mohammad F.
    Abu-Nameh, Eyad S. M.
    AlSawa'eer, Salsabeel
    Saket, Munib M.
    Al Kselat, Ahlam
    Zidan, Amira
    Hasan, Sameer A.
    JORDAN JOURNAL OF CHEMISTRY, 2023, 18 (01) : 13 - 21
  • [50] Electrochemical behaviour of platinum at polymer-modified glassy carbon electrodes
    Zanta, Carmem L. P. S.
    Martinez-Huitle, C. A.
    JOURNAL OF CHEMICAL SCIENCES, 2007, 119 (04) : 283 - 288