Three-dimensional intravascular ultrasound analysis of coronary stent deployment and in-stent neointimal volume: Current clinical practice and the concepts of TRAPIST, ERASER, and ITALICS

被引:0
作者
von Birgelen, C [1 ]
Kutryk, MJB [1 ]
Serruys, PW [1 ]
机构
[1] Erasmus Univ, Hosp Dijkzigt, Thoraxctr, NL-3000 DR Rotterdam, Netherlands
关键词
intravascular ultrasound; stents; restenosis; ECG-gating; three-dimensional reconstruction; coronary artery disease;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intravascular ultrasound (IVUS) permits the detailed examination of coronary stent apposition and expansion in vivo. IVUS assessment of the extent and distribution of in-stent neointima at follow-up is an ideal model for the evaluation of new antiproliferative drugs that aim at a reduced in-stent neointimal hyperplasia. Recently, automated systems for three-dimensional reconstruction and analysis of IVUS images have been developed. This manuscript illustrates the methodology and clinical use of automated three-dimensional IVUS analysis systems during coronary stenting, and highlights the first randomized trials to apply such a technique for the assessment of in-stent neointima.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 6 条
  • [1] Sirolimus-eluting stent for the treatment of in-stent restenosis - A quantitative coronary angiography and three-dimensional intravascular ultrasound study
    Sousa, JE
    Costa, MA
    Abizaid, A
    Sousa, AGMR
    Feres, F
    Mattos, LA
    Centemero, M
    Maldonado, G
    Abizaid, AS
    Pinto, I
    Falotico, R
    Jaeger, J
    Popma, JJ
    Serruys, PW
    CIRCULATION, 2003, 107 (01) : 24 - 27
  • [2] Impact of the cross-sectional geometry of the post-deployment coronary stent on in-stent neointimal hyperplasia - An intravascular ultrasound study
    Murata, T
    Hiro, T
    Fujii, T
    Yasumoto, K
    Murashige, A
    Kohno, M
    Yamada, J
    Miura, T
    Matsuzaki, M
    CIRCULATION JOURNAL, 2002, 66 (05) : 489 - 493
  • [3] First human experience with angiopeptin-eluting stent: A quantitative coronary angiography and three-dimensional intravascular ultrasound study
    Kwok, OH
    Chow, WH
    Law, TC
    Chiu, A
    Ng, W
    Lam, WF
    Hong, MK
    Popma, JJ
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (04) : 541 - 546
  • [4] Multislice CT for assessing in-stent dimensions after left main coronary artery stenting: a comparison with three dimensional intravascular ultrasound
    Roura, Gerard
    Gomez-Lara, Josep
    Ferreiro, Jose L.
    Gomez-Hospital, Joan A.
    Romaguera, Rafael
    Teruel, Luis M.
    Carreno, Elena
    Esplugas, Enric
    Alfonso, Fernando
    Cequier, Angel
    HEART, 2013, 99 (15) : 1106 - 1112
  • [5] Paclitaxel coating reduces in-stent intimal hyperplasia in human coronary arteries - A serial volumetric intravascular ultrasound analysis from the ASian paclitaxel-eluting stent clinical trial (ASPECT)
    Hong, MK
    Mintz, GS
    Lee, CW
    Song, JM
    Han, KH
    Kang, DH
    Song, JK
    Kim, JJ
    Weissman, NJ
    Fearnot, NE
    Park, SW
    Park, SJ
    CIRCULATION, 2003, 107 (04) : 517 - 520
  • [6] Three-dimensional intravascular ultrasound evaluation of carina and plaque shift at the distal left main coronary artery bifurcation after treatment with a one-stent cross-over technique
    Xiu, Jiancheng
    Choi, So-Yeon
    Mintz, Gary S.
    Araki, Hiroshi
    Masuda, Naoki
    Morino, Yoshihiro
    Sonoda, Shinjo
    Tahk, Seung Jea
    Ochiai, Masahiko
    Maehara, Akiko
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (07) : 1142 - 1149