Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation

被引:152
作者
Tong, S. [1 ]
Alessio, A. M. [1 ]
Kinahan, P. E. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
ITERATIVE RECONSTRUCTION; FDG-PET; ALGORITHMS; RESOLUTION; SCANNER; MODEL;
D O I
10.1088/0031-9155/55/5/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The addition of accurate system modeling in PET image reconstruction results in images with distinct noise texture and characteristics. In particular, the incorporation of point spread functions (PSF) into the system model has been shown to visually reduce image noise, but the noise properties have not been thoroughly studied. This work offers a systematic evaluation of noise and signal properties in different combinations of reconstruction methods and parameters. We evaluate two fully 3D PET reconstruction algorithms: (1) OSEM with exact scanner line of response modeled (OSEM+LOR), (2) OSEM with line of response and a measured point spread function incorporated (OSEM+LOR+PSF), in combination with the effects of four post-reconstruction filtering parameters and 1-10 iterations, representing a range of clinically acceptable settings. We used a modified NEMA image quality (IQ) phantom, which was filled with Ge-68 and consisted of six hot spheres of different sizes with a target/background ratio of 4:1. The phantom was scanned 50 times in 3D mode on a clinical system to provide independent noise realizations. Data were reconstructed with OSEM+LOR and OSEM+LOR+PSF using different reconstruction parameters, and our implementations of the algorithms match the vendor's product algorithms. With access to multiple realizations, background noise characteristics were quantified with four metrics. Image roughness and the standard deviation image measured the pixel-to-pixel variation; background variability and ensemble noise quantified the region-to-region variation. Image roughness is the image noise perceived when viewing an individual image. At matched iterations, the addition of PSF leads to images with less noise defined as image roughness (reduced by 35% for unfiltered data) and as the standard deviation image, while it has no effect on background variability or ensemble noise. In terms of signal to noise performance, PSF-based reconstruction has a 7% improvement in contrast recovery at matched ensemble noise levels and 20% improvement of quantitation SNR in unfiltered data. In addition, the relations between different metrics are studied. A linear correlation is observed between background variability and ensemble noise for all different combinations of reconstruction methods and parameters, suggesting that background variability is a reasonable surrogate for ensemble noise when multiple realizations of scans are not available.
引用
收藏
页码:1453 / 1473
页数:21
相关论文
共 30 条
[1]   Modeling and incorporation of system response functions in 3-D whole body PET [J].
Alessio, Adam M. ;
Kinahan, Paul E. ;
Lewellen, Thomas K. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) :828-837
[2]  
ALESSIO AM, 2005, IEEE NUCL SCI S, V4
[3]  
ALESSIO AM, 2010, IEEE T MED IN PRESS
[4]  
[Anonymous], NEMA STAND PUBL NU
[5]   NOISE PROPERTIES OF THE EM ALGORITHM .1. THEORY [J].
BARRETT, HH ;
WILSON, DW ;
TSUI, BMW .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (05) :833-846
[6]   OBJECTIVE ASSESSMENT OF IMAGE QUALITY - EFFECTS OF QUANTUM NOISE AND OBJECT VARIABILITY [J].
BARRETT, HH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1990, 7 (07) :1266-1278
[7]  
Boellaard R, 2004, J NUCL MED, V45, P1519
[8]   Fast reconstruction of 3D PET data with accurate statistical modeling [J].
Comtat, C ;
Kinahan, PE ;
Defrise, M ;
Michel, C ;
Townsend, DW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :1083-1089
[9]   Resolution recovery in PET during AWOSEM reconstruction: A performance evaluation study [J].
De Bernardi, Elisabetta ;
Mazzoli, Marco ;
Zito, Felicia ;
Baselli, Giuseppe .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) :1626-1638
[10]   Reproducibility of quantifying tracer uptake with PET/CT for evaluation of response to therapy [J].
Doot, R. K. ;
Christian, P. E. ;
Mankoff, D. A. ;
Kinahan, P. E. .
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, :2833-+