Effect of ignition position on vented hydrogen-air deflagration in a 1 m3 vessel

被引:33
作者
Li, Hongwei [1 ]
Rui, Shengchao [2 ,3 ]
Guo, Jin [4 ]
Sun, Xuxu [5 ]
Li, Gang [6 ]
Zhang, Jiaqing [7 ]
机构
[1] Anhui Univ Sci & Technol, Sch Chem Engn, Huainan 232001, Anhui, Peoples R China
[2] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Anhui, Peoples R China
[3] Anhui Int Joint Res Ctr Hydrogen Safety, Hefei 230009, Anhui, Peoples R China
[4] Fuzhou Univ, Coll Environm & Resources, Fuzhou 350116, Fujian, Peoples R China
[5] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230009, Anhui, Peoples R China
[6] Northeastern Univ, Fire & Explos Protect Lab, Shenyang 110004, Liaoning, Peoples R China
[7] Anhui Elect Power Res Inst, Hefei 230601, Anhui, Peoples R China
关键词
Hydrogen; Vented explosion; Pressure oscillation; Flame; Safety; EXPLOSION OVERPRESSURES; CYLINDRICAL RIG; GAS EXPLOSION; PRESSURE; GASDYNAMICS; MITIGATION; LOCATION; DUCTS; SIZE; CFD;
D O I
10.1016/j.jlp.2019.103944
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This study investigates the effect of the ignition position on vented hydrogen-air deflagration in a 1 m(3) vessel and evaluates the performance of the commercial computational fluid dynamics (CFD) code FLACS in simulating the vented explosion of hydrogen-air mixtures. First, the differences in the measured pressure-time histories for various ignition locations are presented, and the mechanisms responsible for the generation of different pressure peaks are explained, along with the flame behavior. Secondly, the CFD software FLAGS is assessed against the experimental data. The characteristic phenomena of vented explosion are observed for hydrogen-air mixtures ignited at different ignition positions, such as Helmholtz oscillation for front ignition, the interaction between external explosion and combustion inside the vessel for central ignition, and the wall effect for back-wall ignition. Flame-acoustic interaction are observed in all cases, particularly in those of front ignition and very lean hydrogen-air mixtures. The predicted flame behavior agree well with the experimental data in general while the simulated maximum overpressures are larger than the experimental values by a factor of 1.5-2, which is conservative then would lead to a safe design of explosion panels for instance. Not only the flame development during the deflagration was well-simulated for the different ignition locations, but also the correspondence between the pressure transients and flame behavior was also accurately calculated. The comparison of the predicted results with the experimental data shows the performance of FLACS to model vented mixtures of hydrogen with air ignited in a lab scale vessel. However, the experimental scale is often smaller than that used in practical scenarios, such as hydrogen refueling installations. Thus, future large-scale experiments are necessary to assess the performance of FLACS in practical use.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Effect of hydrogen concentration on the vented explosion of hydrogen-air mixtures in a 5-m-long duct
    Zhang, Kai
    Du, Saifeng
    Chen, Hao
    Wang, Jingui
    Zhang, Jiaqing
    Guo, Yi
    Guo, Jin
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2022, 162 : 978 - 986
  • [32] Effect of ignition position on the run-up distance to DDT for hydrogen-air explosions
    Blanchard, Robert
    Arndt, Detlef
    Graetz, Rainer
    Scheider, Swen
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2011, 24 (02) : 194 - 199
  • [33] Effect of vent area on vented deflagration of hydrogen-methane-air mixtures
    Liu, Wei
    Guo, Jin
    Zhang, Jiaqing
    Zhang, Su
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (09) : 6992 - 6999
  • [34] Investigation on the flame and pressure behaviors of vented hydrogen-air deflagration from a duct-connected vessel: Effects of venting diameter and static activation pressure
    Wang, Tao
    Sheng, Yuhuai
    Nan, Fan
    Liu, Litao
    Chen, Jian
    Meng, Fanyi
    Deng, Jun
    Shi, Jihao
    Luo, Zhenmin
    ENERGY, 2024, 307
  • [35] Numerical simulation study on the effect of ignition position on premixed hydrogen deflagration characteristics in tunnels
    Lei, Baiwei
    Guo, Zekai
    Xu, Zhibing
    Guo, Changna
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 81 : 1394 - 1407
  • [36] The influence of the vent area location on hydrogen-air mixture deflagration in large-scale vessel
    Shebeko, YN
    Korolchenko, YA
    Trunev, AV
    Tsarichenko, SG
    Prostov, EN
    COMBUSTION SCIENCE AND TECHNOLOGY, 1997, 129 (1-6) : 57 - 69
  • [37] Effects of vessel height and ignition position upon explosion dynamics of hydrogen-air mixtures in vessels with low asymmetry ratios
    Wang, Lu-Qing
    Ma, Hong-Hao
    Shen, Zhao-Wu
    FUEL, 2021, 289 (289)
  • [38] Effect of vent size on explosion overpressure and flame behavior during vented hydrogen-air mixture deflagrations
    Tang, Zesi
    Li, Jialin
    Guo, Jin
    Zhang, Su
    Duan, Zaipeng
    NUCLEAR ENGINEERING AND DESIGN, 2020, 361
  • [39] A study on the characteristics of the deflagration of hydrogen-air mixture under the effect of a mesh aluminum alloy
    Pang, Lei
    Wang, Chenxu
    Han, Mengxing
    Xu, Zilong
    JOURNAL OF HAZARDOUS MATERIALS, 2015, 299 : 174 - 180
  • [40] Numerical investigation of the effect of obstacle shape on deflagration to detonation transition in a hydrogen-air mixture
    Coates, Ashley M.
    Mathias, Donovan L.
    Cantwell, Brian J.
    COMBUSTION AND FLAME, 2019, 209 : 278 - 290