Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath-hold

被引:35
|
作者
Weingaertner, Sebastian [1 ,2 ,3 ]
Moeller, Steen [2 ]
Schmitter, Sebastian [2 ,4 ]
Auerbach, Edward [2 ]
Kellman, Peter [5 ]
Shenoy, Chetan [6 ]
Akcakaya, Mehmet [1 ,2 ]
机构
[1] Univ Minnesota, Elect & Comp Engn, 200 Union St SE, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Comp Assisted Clin Med, Mannheim, Germany
[4] Phys Tech Bundesanstalt, Med Phys & Metrol Informat Technol, Berlin, Germany
[5] NHLBI, NIH, Bldg 10, Bethesda, MD 20892 USA
[6] Univ Minnesota, Dept Med, Div Cardiovasc, Box 736 UMHC, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
myocardial T-1 mapping; simultaneous multislice imaging; multiband; saturation recovery; SAPPHIRE; SPOILED GRADIENT-ECHO; INVERSION-RECOVERY; MOTION CORRECTION; TISSUE CHARACTERIZATION; T1; QUANTIFICATION; RESOLUTION; ACCURACY; HEART; MOLLI;
D O I
10.1002/mrm.26770
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a saturation recovery myocardial T-1 mapping method for the simultaneous multislice acquisition of three slices. MethodsSaturation pulse-prepared heart rate independent inversion recovery (SAPPHIRE) T-1 mapping was implemented with simultaneous multislice imaging using FLASH readouts for faster coverage of the myocardium. Controlled aliasing in parallel imaging (CAIPI) was used to achieve minimal noise amplification in three slices. Multiband reconstruction was performed using three linear reconstruction methods: Slice- and in-plane GRAPPA, CG-SENSE, and Tikhonov-regularized CG-SENSE. Accuracy, spatial variability, and interslice leakage were compared with single-band T-1 mapping in a phantom and in six healthy subjects. ResultsMultiband phantom T-1 times showed good agreement with single-band T-1 mapping for all three reconstruction methods (normalized root mean square error <1.0%). The increase in spatial variability compared with single-band imaging was lowest for GRAPPA (1.29-fold), with higher penalties for Tikhonov-regularized CG-SENSE (1.47-fold) and CG-SENSE (1.52-fold). In vivo multiband T-1 times showed no significant difference compared with single-band (T-1 timeintersegmental variability: single-band, 1580 +/- 119 ms; GRAPPA, 1572 +/- 145 ms; CG-SENSE, 1579 +/- 159 ms; Tikhonov, 1586 +/- 150 ms [analysis of variance; P=0.86]). Interslice leakage was smallest for GRAPPA (5.4%) and higher for CG-SENSE (6.2%) and Tikhonov-regularized CG-SENSE (7.9%). ConclusionMultiband accelerated myocardial T-1 mapping demonstrated the potential for single-breath-hold T-1 quantification in 16 American Heart Association segments over three slices. A 1.2- to 1.4-fold higher in vivo spatial variability was observed, where GRAPPA-based reconstruction showed the highest homogeneity and the least interslice leakage. Magn Reson Med 78:462-471, 2017. (c) 2017 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:462 / 471
页数:10
相关论文
共 50 条
  • [21] Saturation Recovery Single-Shot Acquisition (SASHA) for Myocardial T1 Mapping
    Chow, Kelvin
    Flewitt, Jacqueline A.
    Green, Jordin D.
    Pagano, Joseph J.
    Friedrich, Matthias G.
    Thompson, Richard B.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) : 2082 - 2095
  • [22] Native myocardial T1 mapping using inversion recovery T1-weighted turbo field echo sequence
    Kida, Katsuhiro
    Kurosaki, Takamasa
    Fukui, Ryohei
    Matsuura, Ryutaro
    Goto, Sachiko
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (02) : 425 - 432
  • [23] Improved Simultaneous Multi-slice imaging with Composition of k-space Interpolations (SMS-COOKIE) for myocardial T1 mapping
    Demirel, Omer Burak
    Weingartner, Sebastian
    Moeller, Steen
    Akcakaya, Mehmet
    PLOS ONE, 2023, 18 (07):
  • [24] LIVER-BUDA-SAGE: SIMULTANEOUS WHOLE LIVER T2 AND T*2 MAPPING IN ONE BREATH-HOLD
    Zhang, Zijing
    Ye, Huihui
    Li, Maosen
    Liu, Huafeng
    Bilgic, Berkin
    2022 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (IEEE ISBI 2022), 2022,
  • [25] Native Myocardial T1 Mapping by Cardiovascular Magnetic Resonance Imaging in Subclinical Cardiomyopathy in Patients With Systemic Lupus Erythematosus
    Puntmann, Valentina O.
    D'Cruz, David
    Smith, Zachary
    Pastor, Ana
    Choong, Peng
    Voigt, Tobias
    Carr-White, Gerry
    Sangle, Shirish
    Schaeffter, Tobias
    Nagel, Eike
    CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (02) : 295 - 301
  • [26] Clinical impact of native T1 mapping for detecting myocardial impairment in takotsubo cardiomyopathy
    Aikawa, Yukio
    Noguchi, Teruo
    Morita, Yoshiaki
    Tateishi, Emi
    Kono, Atsushi
    Miura, Hiroyuki
    Komori, Yoshiaki
    Asaumi, Yasuhide
    Fukuda, Tetsuya
    Yasuda, Satoshi
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 (10) : 1147 - 1155
  • [27] Fat-saturated dark-blood cardiac T2 mapping in a single breath-hold
    Hu, Chenxi
    Huber, Steffen
    Nguyen, Vinh
    Baldassarre, Lauren
    Mojibian, Hamid
    Peters, Dana
    MAGNETIC RESONANCE IMAGING, 2021, 81 : 24 - 32
  • [28] Adenosine stress native T1 mapping in severe aortic stenosis: evidence for a role of the intravascular compartment on myocardial T1 values
    Mahmod, Masliza
    Piechnik, Stefan K.
    Levelt, Eylem
    Ferreira, Vanessa M.
    Francis, Jane M.
    Lewis, Andrew
    Pal, Nikhil
    Dass, Sairia
    Ashrafian, Houman
    Neubauer, Stefan
    Karamitsos, Theodoros D.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [29] Breath-hold MR measurements of fat fraction, T1, and T2* of water and fat in vertebral bone marrow
    Le Ster, Caroline
    Gambarota, Giulio
    Lasbleiz, Jeremy
    Guillin, Raphael
    Decaux, Olivier
    Saint-Jalmes, Herve
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (03) : 549 - 555
  • [30] Magnetization transfer contrast of hepatic lesions in breath-hold gradient-echo images of different T1 weighting
    Schick, F
    Stern, W
    Forster, J
    Laniado, M
    Lutz, O
    Claussen, CD
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02): : 280 - 285