Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath-hold

被引:35
|
作者
Weingaertner, Sebastian [1 ,2 ,3 ]
Moeller, Steen [2 ]
Schmitter, Sebastian [2 ,4 ]
Auerbach, Edward [2 ]
Kellman, Peter [5 ]
Shenoy, Chetan [6 ]
Akcakaya, Mehmet [1 ,2 ]
机构
[1] Univ Minnesota, Elect & Comp Engn, 200 Union St SE, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Comp Assisted Clin Med, Mannheim, Germany
[4] Phys Tech Bundesanstalt, Med Phys & Metrol Informat Technol, Berlin, Germany
[5] NHLBI, NIH, Bldg 10, Bethesda, MD 20892 USA
[6] Univ Minnesota, Dept Med, Div Cardiovasc, Box 736 UMHC, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
myocardial T-1 mapping; simultaneous multislice imaging; multiband; saturation recovery; SAPPHIRE; SPOILED GRADIENT-ECHO; INVERSION-RECOVERY; MOTION CORRECTION; TISSUE CHARACTERIZATION; T1; QUANTIFICATION; RESOLUTION; ACCURACY; HEART; MOLLI;
D O I
10.1002/mrm.26770
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a saturation recovery myocardial T-1 mapping method for the simultaneous multislice acquisition of three slices. MethodsSaturation pulse-prepared heart rate independent inversion recovery (SAPPHIRE) T-1 mapping was implemented with simultaneous multislice imaging using FLASH readouts for faster coverage of the myocardium. Controlled aliasing in parallel imaging (CAIPI) was used to achieve minimal noise amplification in three slices. Multiband reconstruction was performed using three linear reconstruction methods: Slice- and in-plane GRAPPA, CG-SENSE, and Tikhonov-regularized CG-SENSE. Accuracy, spatial variability, and interslice leakage were compared with single-band T-1 mapping in a phantom and in six healthy subjects. ResultsMultiband phantom T-1 times showed good agreement with single-band T-1 mapping for all three reconstruction methods (normalized root mean square error <1.0%). The increase in spatial variability compared with single-band imaging was lowest for GRAPPA (1.29-fold), with higher penalties for Tikhonov-regularized CG-SENSE (1.47-fold) and CG-SENSE (1.52-fold). In vivo multiband T-1 times showed no significant difference compared with single-band (T-1 timeintersegmental variability: single-band, 1580 +/- 119 ms; GRAPPA, 1572 +/- 145 ms; CG-SENSE, 1579 +/- 159 ms; Tikhonov, 1586 +/- 150 ms [analysis of variance; P=0.86]). Interslice leakage was smallest for GRAPPA (5.4%) and higher for CG-SENSE (6.2%) and Tikhonov-regularized CG-SENSE (7.9%). ConclusionMultiband accelerated myocardial T-1 mapping demonstrated the potential for single-breath-hold T-1 quantification in 16 American Heart Association segments over three slices. A 1.2- to 1.4-fold higher in vivo spatial variability was observed, where GRAPPA-based reconstruction showed the highest homogeneity and the least interslice leakage. Magn Reson Med 78:462-471, 2017. (c) 2017 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:462 / 471
页数:10
相关论文
共 50 条
  • [1] Single Breath-Hold T1ρ-Mapping of the Heart for Endogenous Assessment of Myocardial Fibrosis
    van Oorschot, Joep W. M.
    Visser, Fredy
    Eikendal, Anouk L. M.
    Vonken, Evert-jan P. A.
    Luijten, Peter R.
    Chamuleau, Steven A. J.
    Leiner, Tim
    Zwanenburg, Jaco J. M.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (08) : 505 - 512
  • [2] Single breath-hold MR T1 mapping in the heart: Hybrid MOLLI combining saturation and inversion recovery
    Yu, Chun -Yang
    Huang, Teng-Yi
    Chung, Hsiao-Wen
    MAGNETIC RESONANCE IMAGING, 2023, 96 : 85 - 92
  • [3] Clinical feasibility of 3D-QALAS - Single breath-hold 3D myocardial T1 and T2-mapping
    Kvernby, Sofia
    Warntjes, Marcel
    Engvall, Jan
    Carlhall, Carl-Johan
    Ebbers, Tino
    MAGNETIC RESONANCE IMAGING, 2017, 38 : 13 - 20
  • [4] Free-breathing multislice native myocardial T1 mapping using the slice-interleaved T1 (STONE) sequence
    Weingaertner, Sebastian
    Roujol, Sebastien
    Akcakaya, Mehmet
    Basha, Tamer A.
    Nezafat, Reza
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (01) : 115 - 124
  • [5] Single breath-hold 3D cardiac T1 mapping using through-time spiral GRAPPA
    Chen, Yong
    Lo, Wei-Ching
    Hamilton, Jesse I.
    Barkauskas, Kestutis
    Saybasili, Haris
    Wright, Katherine L.
    Batesole, Joshua
    Griswold, Mark A.
    Gulani, Vikas
    Seiberlich, Nicole
    NMR IN BIOMEDICINE, 2018, 31 (06)
  • [6] Single breath-hold T1 measurement using low flip angle TrueFISP
    Bokacheva, L
    Huang, AJ
    Chen, Q
    Oesingmann, N
    Storey, P
    Rusinek, H
    Lee, VS
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) : 1186 - 1190
  • [7] Single breath-hold CINE imaging with combined simultaneous multislice and region-optimized virtual coils
    Kim, Daeun
    Coll-Font, Jaume
    Lobos, Rodrigo A.
    Stab, Daniel
    Pang, Jianing
    Foster, Anna
    Garrett, Thomas
    Bi, Xiaoming
    Speier, Peter
    Haldar, Justin P.
    Nguyen, Christopher
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (01) : 222 - 230
  • [8] FASt single-breathhold 2D multislice myocardial T1 mapping (FAST1) at 1.5T for full left ventricular coverage in three breathholds
    Li Huang
    Neji, Radhouene
    Nazir, Muhummad Sohaib
    Whitaker, John
    Duong, Phuoc
    Reid, Fiona
    Bosio, Filippo
    Chiribiri, Amedeo
    Razavi, Reza
    Roujol, Sebastien
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (02) : 492 - 504
  • [9] Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS
    Kvernby, Sofia
    Warntjes, Marcel Jan Bertus
    Haraldsson, Henrik
    Carlhall, Carl-Johan
    Engvall, Jan
    Ebbers, Tino
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [10] Free-breathing simultaneous native myocardial T1, T2 and T1ρ mapping with Cartesian acquisition and dictionary matching
    Lyu, Zhenfeng
    Hua, Sha
    Xu, Jian
    Shen, Yiwen
    Guo, Rui
    Hu, Peng
    Qi, Haikun
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)