Positive End-Expiratory Pressure Ventilation Induces Longitudinal Atrophy in Diaphragm Fibers

被引:70
|
作者
Lindqvist, Johan [1 ]
van den Berg, Marloes [2 ]
van der Pijl, Robbert [1 ,2 ]
Hooijman, Pleuni E. [2 ]
Beishuizen, Albertus [6 ]
Elshof, Judith [3 ]
de Waard, Monique [3 ]
Girbes, Armand [3 ]
Man, Angelique Spoelstra-de [3 ]
Shi, Zhong-Hua [7 ]
van den Brom, Charissa [4 ]
Bogaards, Sylvia [2 ]
Shen, Shengyi [1 ]
Strom, Joshua [1 ]
Granzier, Henk [1 ]
Kole, Jeroen [2 ]
Musters, Rene J. P. [2 ]
Paul, Marinus A. [5 ]
Heunks, Leo M. A. [3 ,4 ]
Ottenheijm, Coen A. C. [1 ,2 ]
机构
[1] Univ Arizona, Cellular & Mol Med, Tucson, AZ USA
[2] Vrije Univ, Med Ctr, Dept Physiol, Amsterdam, Netherlands
[3] Vrije Univ, Med Ctr, Dept Intens Care, Amsterdam, Netherlands
[4] Vrije Univ, Med Ctr, Dept Anesthesiol, Amsterdam, Netherlands
[5] Vrije Univ, Med Ctr, Dept Cardiothorac Surg, Amsterdam, Netherlands
[6] Med Spectrum Twente, Dept Intens Care, Enschede, Netherlands
[7] Capital Med Univ, Beijing Tiantan Hosp, Dept Crit Care Med, Beijing, Peoples R China
关键词
mechanical ventilation; PEEP; diaphragm; critically ill; INTENSIVE-CARE-UNIT; CONTROLLED MECHANICAL VENTILATION; PULMONARY ARTERIAL-HYPERTENSION; CRITICALLY-ILL PATIENTS; NEMALINE MYOPATHY; MUSCLE WEAKNESS; CONTRACTILE PROPERTIES; PASSIVE TENSION; SKELETAL-MUSCLE; DYSFUNCTION;
D O I
10.1164/rccm.201709-1917OC
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Rationale: Diaphragm weakness in critically ill patients prolongs ventilator dependency and duration of hospital stay and increases mortality and healthcare costs. Themechanisms underlying diaphragm weakness include cross-sectional fiber atrophy and contractile protein dysfunction, but whether additional mechanisms are at play is unknown. Objectives: To test the hypothesis that mechanical ventilation with positive end-expiratory pressure (PEEP) induces longitudinal atrophy by displacing the diaphragm in the caudal direction and reducing the length of fibers. Methods: We studied structure and function of diaphragm fibers of mechanically ventilated critically ill patients and mechanically ventilated rats with normal and increased titin compliance. Measurements and Main Results: PEEP causes a caudal movement of the diaphragm, both in critically ill patients and in rats, and this caudal movement reduces fiber length. Diaphragm fibers of 18-hour mechanically ventilated rats (PEEP of 2.5 cm H-2 O) adapt to the reduced length by absorbing serially linked sarcomeres, the smallest contractile units in muscle (i. e., longitudinal atrophy). Increasing the compliance of titin molecules reduces longitudinal atrophy. Conclusions: Mechanical ventilation with PEEP results in longitudinal atrophy of diaphragm fibers, a response that is modulated by the elasticity of the giant sarcomeric protein titin. We postulate that longitudinal atrophy, in concert with the aforementioned cross-sectional atrophy, hampers spontaneous breathing trials in critically ill patients: during these efforts, end-expiratory lung volume is reduced, and the shortened diaphragm fibers are stretched to excessive sarcomere lengths. At these lengths, muscle fibers generate less force, and diaphragm weakness ensues.
引用
收藏
页码:472 / 485
页数:14
相关论文
共 50 条
  • [1] Setting positive end-expiratory pressure: role in diaphragm-protective ventilation
    Wennen, Myrte
    Claassen, Wout
    Heunks, Leo
    CURRENT OPINION IN CRITICAL CARE, 2024, 30 (01) : 61 - 68
  • [2] MECHANICS OF VENTILATION WITH POSITIVE END-EXPIRATORY PRESSURE
    HOBELMANN, CF
    SMITH, DE
    VIRGILIO, RW
    PETERS, RM
    ANNALS OF THORACIC SURGERY, 1977, 24 (01): : 68 - 76
  • [3] The use of positive end-expiratory pressure in mechanical ventilation
    Acosta, Pilar
    Santisbon, Edgardo
    Varon, Joseph
    CRITICAL CARE CLINICS, 2007, 23 (02) : 251 - +
  • [4] HEMODYNAMIC RESPONSE TO VENTILATION WITH POSITIVE END-EXPIRATORY PRESSURE
    VAZQUEZMATA, G
    NETCASTEL, A
    MARTINEZVILCHES, R
    GRANGEDAVIES, G
    ARTIGASRAVENTOS, A
    MARRUECOSSANT, L
    BOSCHTORRAS, E
    MEDICINA CLINICA, 1978, 70 (07): : 315 - 321
  • [5] Heterogeneity in ventilation during positive end-expiratory pressure
    Mukesh Tripathi
    Mamta Pandey
    Critical Care, 14 (4):
  • [6] Positive end-expiratory pressure or no positive end-expiratory pressure: is that the question to be asked?
    Villar, J
    CRITICAL CARE, 2003, 7 (02): : 192 - 192
  • [7] Positive end-expiratory pressure or no positive end-expiratory pressure: is that the question to be asked?
    Jesús Villar
    Critical Care, 7
  • [8] Setting positive end-expiratory pressure: lung and diaphragm ultrasound
    Mousa, Amne
    Klompmaker, Peter
    Tuinman, Pieter R.
    CURRENT OPINION IN CRITICAL CARE, 2024, 30 (01) : 53 - 60
  • [9] THE EFFECT OF CONTINUOUS POSITIVE AIRWAY PRESSURE VERSUS POSITIVE END-EXPIRATORY PRESSURE ON THE DIAPHRAGM
    ROAD, JD
    LEEVERS, AM
    GRASSINO, A
    JOURNAL OF CRITICAL CARE, 1991, 6 (03) : 136 - 142
  • [10] INADVERTENT POSITIVE END-EXPIRATORY PRESSURE DURING MECHANICAL VENTILATION
    BANCALARI, E
    JOURNAL OF PEDIATRICS, 1986, 108 (04): : 567 - 569