Reliability of home blood pressure monitoring devices in pregnancy
被引:20
|
作者:
Tremonti, Chris
论文数: 0引用数: 0
h-index: 0
机构:
Royal North Shore Hosp, St Leonards, NSW 2065, Australia
Sutherland Hosp, Sutherland, NSW 2229, AustraliaRoyal North Shore Hosp, St Leonards, NSW 2065, Australia
Tremonti, Chris
[1
,2
]
Beddoe, Jennifer
论文数: 0引用数: 0
h-index: 0
机构:
St George Hosp, Kogarah, NSW 2217, AustraliaRoyal North Shore Hosp, St Leonards, NSW 2065, Australia
Beddoe, Jennifer
[3
]
Brown, Mark A.
论文数: 0引用数: 0
h-index: 0
机构:
St George Hosp, Kogarah, NSW 2217, AustraliaRoyal North Shore Hosp, St Leonards, NSW 2065, Australia
Brown, Mark A.
[3
]
机构:
[1] Royal North Shore Hosp, St Leonards, NSW 2065, Australia
[2] Sutherland Hosp, Sutherland, NSW 2229, Australia
Home blood pressure monitors are freely available and used for women during pregnancy. The exact role of home blood pressure monitoring in pregnancy remains uncertain, and few such monitors have been validated for use in pregnancy. As it has been our Unit's policy to test these devices against sphygmomanometry (as the gold standard) before clinical use for some years now, we undertook this study to ascertain the degree of accuracy or inaccuracy of these devices in usual clinical practice. We analysed 9 consecutive blood pressures (BP) alternately using an automated home BP device and sphygmomanometry in 127 pregnant women with hypertension using two different methods: a) a modified version of the British Hypertension Society's guidelines for analysing automated devices, and b) examining the difference between the mean of blood pressure readings by the device and sphygmomanometry for each patient. 87 devices (69%) had systolic BP within 5 mmHg or less and 98 (77%) were within 5 mmHg for diastolic BP. The frequency of systolic BPs within 5 mmHg was similar for non-validated vs. validated devices (75 vs. 60%; p = 0.23). Similarly, diastolic BP within 5 mmHg was similar for non-validated vs. validated devices (86 vs. 68%, p = 0.06). Our findings showed that a wide variety of devices are used and few if any have been formally validated for use in pregnancy. As a group the devices provide accurate BP in the majority of women, but up to a quarter will have a BP difference of at least 5 mmHg, and this is not related to the absolute BP. Furthermore using a home BP device validated for general use in non-pregnant subjects appeared as reliable as using other non-validated devices. On the basis of these data we recommended clinicians always perform their own analysis of a patient's home BP machine accuracy prior to home use using a simple protocol as described here, even if the machine has been validated for general use. (C) 2017 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.
机构:
Univ Fed Rio de Janeiro, Sch Med, Dept Internal Med, Univ Hosp Clementino Fraga Filho, Rio De Janeiro, BrazilUniv Fed Rio de Janeiro, Sch Med, Dept Internal Med, Univ Hosp Clementino Fraga Filho, Rio De Janeiro, Brazil
Muxfeldt, Elizabeth S.
Barros, Guilherme S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Rio de Janeiro, Sch Med, Dept Internal Med, Univ Hosp Clementino Fraga Filho, Rio De Janeiro, BrazilUniv Fed Rio de Janeiro, Sch Med, Dept Internal Med, Univ Hosp Clementino Fraga Filho, Rio De Janeiro, Brazil
Barros, Guilherme S.
Viegas, Bianca B.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Rio de Janeiro, Sch Med, Dept Internal Med, Univ Hosp Clementino Fraga Filho, Rio De Janeiro, BrazilUniv Fed Rio de Janeiro, Sch Med, Dept Internal Med, Univ Hosp Clementino Fraga Filho, Rio De Janeiro, Brazil
Viegas, Bianca B.
Carlos, Fernanda O.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Rio de Janeiro, Sch Med, Dept Internal Med, Univ Hosp Clementino Fraga Filho, Rio De Janeiro, BrazilUniv Fed Rio de Janeiro, Sch Med, Dept Internal Med, Univ Hosp Clementino Fraga Filho, Rio De Janeiro, Brazil
Carlos, Fernanda O.
Salles, Gil F.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Rio de Janeiro, Sch Med, Dept Internal Med, Univ Hosp Clementino Fraga Filho, Rio De Janeiro, BrazilUniv Fed Rio de Janeiro, Sch Med, Dept Internal Med, Univ Hosp Clementino Fraga Filho, Rio De Janeiro, Brazil
机构:
Univ Sydney, Sydney Med Sch, Sydney, NSW 2006, Australia
Royal Prince Alfred Hosp, Dept Renal Med, Missenden Rd, Camperdown, NSW 2050, AustraliaUniv Sydney, Sydney Med Sch, Sydney, NSW 2006, Australia
Lan, Patrick G.
Hyett, Jon
论文数: 0引用数: 0
h-index: 0
机构:
Royal Prince Alfred Hosp, Dept High Risk Obstet, Camperdown, NSW 2050, Australia
Univ Sydney, Discipline Obstet Gynaecol & Neonatol, Sydney, NSW 2006, AustraliaUniv Sydney, Sydney Med Sch, Sydney, NSW 2006, Australia
Hyett, Jon
Gillin, Adrian G.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sydney, Sydney Med Sch, Sydney, NSW 2006, Australia
Royal Prince Alfred Hosp, Dept Renal Med, Missenden Rd, Camperdown, NSW 2050, AustraliaUniv Sydney, Sydney Med Sch, Sydney, NSW 2006, Australia