Analysis of Ultra-Trace Impurities in High Purity Molybdenum Powder through Inductively Coupled Plasma Tandem Mass Spectrometry

被引:5
作者
Fu Liang [1 ,2 ]
Shi Shu-yun [2 ]
Tang You-gen [2 ]
Wang Hai-yan [2 ]
机构
[1] Yangtze Normal Univ, Collaborat Innovat Ctr Green Dev Wuling Mt Areas, Chongqing 408100, Peoples R China
[2] Cent S Univ, Sch Chem & Chem Engn, Changsha 410083, Hunan, Peoples R China
关键词
ICP-MS/MS; High purity molybdenum powder; Impurity elements; Mass-shift; On-mass; ATOMIC-ABSORPTION-SPECTROMETRY; EMISSION-SPECTROMETRY; ICP-MS/MS; ELEMENTS; MATRIX; MS; SEPARATION; TRIOXIDE; URANIUM; IRON;
D O I
10.3964/j.issn.1000-0593(2018)08-2588-07
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
An analytical method for the determination of ultra-trace impurities in high purity molybdenum was established by inductively coupled plasma tandem mass spectrometry (ICP-MS/MS). In MS/MS mode, H-2 was used as the reaction gas to measure Si and Ca through the H-2 on-mass method. O-2 was employed as the reaction gas to measure the Cd via the O-2 on-mass method, and P, As, Se, Ta, Sn, Sb, Ba, and W were measured by the O-2 mass-shift method. NH3/He was adopted as the reaction gas, so that Na, Mg, Al, K, and V could be measured by NH3/He on-mass method, and Ti, Cr, Mn, Fe, Co, Ni, Cu, and Zn could be measured by the NH3/He mass- shift method. Pb, Bi, Th, and U were measured in single quadropole (SQ) mode without gas. Compared with conventional collision/reaction cell (CRC) inductively coupled plasma mass spectrometry (ICP-MS) , the background equivalent concentration (BEC) and detection limit of analyte in this method were lower, and the mass spectrum interference could be eliminated more thoroughly. Under optimized working conditions, the calibration curves of analytes showed good linearity with linear correlation coefficient (R-2)>= 0. 999 7. The detection limit was 0. 04 similar to 50. 1 ng . L-1, the spike recoveries were 92. 2%similar to 107. 4% and the relative standard deviation (RSD) was <= 4. 3%, indicating that the proposal method has excellent accuracy and precision. The results of the sample analysis showed that the method can be used for the determination of 28 impurity elements in high purity molybdenum powder with purity of 5N (>= 99. 999%).
引用
收藏
页码:2588 / 2594
页数:7
相关论文
共 21 条
[1]  
AN Geng, 2011, CHINA MOLYBDENUM IND, V35, P45
[2]   Accurate Quantification of Selenoprotein P (SEPP1) in Plasma Using Isotopically Enriched Seleno-peptides and Species-Specific Isotope Dilution with HPLC Coupled to ICP-MS/MS [J].
Deitrich, Christian L. ;
Cuello-Nunez, Susana ;
Kmiotek, Diana ;
Torma, Frank Attila ;
Busto, Maria Estela del Castillo ;
Fisicaro, Paola ;
Goenaga-Infante, Heidi .
ANALYTICAL CHEMISTRY, 2016, 88 (12) :6357-6365
[3]   DETERMINATION OF TRACE-ELEMENTS IN HIGH-PURITY MOLYBDENUM TRIOXIDE BY SLURRY SAMPLING ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
DOCEKAL, B ;
KRIVAN, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (04) :637-641
[4]   SEPARATION OF ANALYTE AND MATRIX FOR THE DIRECT ANALYSIS OF HIGH-PURITY MOLYBDENUM-BASED MATERIALS BY ELECTROTHERMAL ATOMIC SPECTROMETRY METHODS .1. RADIOTRACER INVESTIGATION OF THERMAL EXTRACTION OF IMPURITIES IN A GRAPHITE CUP [J].
DOCEKAL, B ;
KRIVAN, V ;
FRANEK, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (06) :577-582
[5]   DETERMINATION OF TRACE IMPURITIES IN POWDERED MOLYBDENUM METAL AND MOLYBDENUM SILICIDE BY SOLID SAMPLING GFAAS [J].
DOCEKAL, B ;
KRIVAN, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (4-7) :517-526
[6]   Determination of Phosphorus and Silicon in Edible Vegetable Oil by Inductively Coupled Plasma-Tandem Mass Spectrometry [J].
Fu Liang ;
Shi Shu-Yun .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (08) :1222-1226
[7]   Multi-element analysis of water decoction of medicine food homology plants using inductively coupled plasma-tandem mass spectrometry [J].
Fu, Liang ;
Shi, Shu-Yun ;
Chen, Xiao-Qing .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 133 :34-39
[8]   Determination of trace elements in high-purity molybdenum by solid-phase extraction/ICP-MS [J].
Hasegawa, SI ;
Yamaguchi, H ;
Yamada, K ;
Kobayashi, T .
MATERIALS TRANSACTIONS, 2004, 45 (03) :925-929
[9]   Rapid screening of copper intermediates in Cu(I)-catalyzed azide-alkyne cycloaddition using a modified ICP-MS/MS platform [J].
He, Qian ;
Xing, Zhi ;
Wei, Chao ;
Fang, Xiang ;
Zhang, Sichun ;
Zhang, Xinrong .
CHEMICAL COMMUNICATIONS, 2016, 52 (69) :10501-10504
[10]   ICP-MS analysis of high purity molybdenum used as SI-traceable standard of high metrological quality [J].
Kipphardt, H ;
Czerwensky, M ;
Matschat, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (01) :28-34