Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLARE

被引:76
作者
Karger, N [1 ]
Biederer, J [1 ]
Lüsse, S [1 ]
Grimm, J [1 ]
Steffens, JC [1 ]
Heller, M [1 ]
Glüer, CC [1 ]
机构
[1] Klinikum CAU Kiel, Radiol Diagnost Klin, D-24105 Kiel, Germany
关键词
perfusion; FAIR; kidney; arterial spin labeling;
D O I
10.1016/S0730-725X(00)00155-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative perfusion imaging of human kidneys was performed using arterial spin labeling MRT with a fast spin echo readout-sequence. Perfusion maps of centrally located single slices were obtained in axial and coronal orientations. In ten healthy volunteers, the mean value of perfusion was 213 +/- 55 mL(100g min) with a range from 140 to 319 mL/(100g min). These results are in accordance with literature data, considering the fact that FAIR only measures the perfusion component normal to the imaging plane. Intra-individual reproducibility errors of +/- 11% were smaller than the natural interindividual variability of renal perfusion (SD = +/- 25%). Perfusion in the cortex was approximately 3-4 times higher compared to the medulla. Considering the relatively high resolution of 2 x 2 x 10 mm(3), the ability to quantify perfusion, and the lack of ionizing radiation and contrast media, this technique should prove useful in diagnosing renal pathologies that are associated with reductions in tissue perfusion. (C) 2000 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:641 / 647
页数:7
相关论文
共 25 条
  • [1] In vivo quantitative mapping of cardiac perfusion in rats using a noninvasive MR spin-labeling method
    Belle, V
    Kahler, E
    Waller, C
    Rommel, E
    Voll, S
    Hiller, KH
    Bauer, WR
    Haase, A
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1240 - 1245
  • [2] Berr SS, 1999, J MAGN RESON IMAGING, V10, P886, DOI 10.1002/(SICI)1522-2586(199911)10:5<886::AID-JMRI38>3.0.CO
  • [3] 2-P
  • [4] STAR-HASTE: Perfusion imaging without magnetic susceptibility artifact
    Chen, Q
    Siewert, B
    Bly, BM
    Warach, S
    Edelman, RR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) : 404 - 408
  • [5] PERFUSION IMAGING
    DETRE, JA
    LEIGH, JS
    WILLIAMS, DS
    KORETSKY, AP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) : 37 - 45
  • [6] Dworkin LD, 1981, KIDNEY
  • [7] Frank LR, 1999, MAGN RESON MED, V42, P258, DOI 10.1002/(SICI)1522-2594(199908)42:2<258::AID-MRM7>3.0.CO
  • [8] 2-E
  • [9] In vivo perfusion measurements in the human placenta using echo planar imaging at 0.5 T
    Gowland, PA
    Francis, S
    Duncan, KR
    Freeman, AJ
    Issa, B
    Moore, RJ
    Bowtell, RW
    Baker, PN
    Johnson, IR
    Worthington, BS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) : 467 - 473
  • [10] Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional brain imaging
    Kim, SG
    Tsekos, NV
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) : 425 - 435