DURATION OF PRONE POSITIONING AFTER MACULAR HOLE SURGERY DETERMINED BY SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY

被引:15
|
作者
Sano, Masahiko [1 ]
Inoue, Makoto [1 ]
Itoh, Yuji [1 ]
Kita, Yoshiyuki [1 ]
Hirota, Kazunari [1 ]
Koto, Takashi [1 ]
Hirakata, Akito [1 ]
机构
[1] Kyorin Univ, Sch Med, Kyorin Eye Ctr, 6-20-2 Shinkawa, Mitaka, Tokyo 1818611, Japan
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2017年 / 37卷 / 08期
关键词
macular hole; optical coherence tomography; pars plana vitrectomy; swept-source optical coherence tomography; gas tamponade; RANDOMIZED CONTROLLED-TRIAL; FACE-DOWN; VITREOUS SURGERY; GAS TAMPONADE; VITRECTOMY; REPAIR; CLOSURE; EYES; AIR;
D O I
10.1097/IAE.0000000000001394
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the closure rate of macular hole closure and duration of the prone positioning after macular hole (MH) surgery with two protocols for halting the prone positioning. Methods: The authors studied 129 eyes of 125 consecutive patients with MH who had undergone vitrectomy. In 60 eyes of 59 patients, the prone positioning was halted after detecting an MH closure in the swept-source optical coherence tomographic images (SS group). In 69 eyes of 66 patients, the prone position was halted by the surgeon's decision (conventional group). The MH closure rate and duration of the prone positioning were compared. Results: Clear images of the MH were recorded in the SS group on postoperative Day 1 in 58 eyes (97%). In the SS group, MH closure was detected on postoperative Day 1 in 47 eyes (78%) and Day 2 in 4 eyes (7%). The MH was closed in 58 eyes (97%) in the SS group and 69 eyes (100%) in the conventional group (P = 0.21). None of the eyes had a reopening of the MH. The duration of prone positioning in the SS group was 1.8 +/- 2.5 days, which was significantly shorter than that in the conventional group at 8.4 +/- 4.2 days (P < 0.0001). Conclusion: The SS-OCT protocol can significantly decrease the duration of the prone positioning without a reopening of the MH.
引用
收藏
页码:1483 / 1491
页数:9
相关论文
共 50 条
  • [41] Findings of optical coherence tomography (OCT) before and after macular hole surgery
    Göbel, W
    Schrader, WF
    Sehrenker, M
    Klink, T
    OPHTHALMOLOGE, 2000, 97 (04): : 251 - 256
  • [42] CHOROIDAL THICKNESS IN DIABETIC RETINOPATHY ASSESSED WITH SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY
    Lains, Ines
    Talcott, Katherine E.
    Santos, Ana R.
    Marques, Joao H.
    Gil, Pedro
    Gil, Joao
    Figueira, Joao
    Husain, Deeba
    Kim, Ivana K.
    Miller, Joan W.
    Silva, Rufino
    Miller, John B.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (01): : 173 - 182
  • [43] Swept-source optical coherence tomography objective composite activity score for uveitis
    Llorenc, Victor
    Serrano, Alba R.
    Mesquida, Marina
    Lin, Phoebe
    Esquinas, Cristina
    Sainz-de-la-Maza, Maite
    Metea, Christina
    Bosch, Anna
    Calvo, Maria
    Balter, Ariel
    Nakamura, Yukiko
    Molins, Blanca
    Alba, Carmen
    Suhler, Eric
    Adan, Alfredo
    ACTA OPHTHALMOLOGICA, 2021, 99 (07) : 756 - 764
  • [44] Alterations in the Neural and Connective Tissue Components of Glaucomatous Cupping After Glaucoma Surgery Using Swept-Source Optical Coherence Tomography
    Yoshikawa, Munemitsu
    Akagi, Tadamichi
    Hangai, Masanori
    Ohashi-Ikeda, Hanako
    Takayama, Kohei
    Morooka, Satoshi
    Kimura, Yugo
    Nakano, Noriko
    Yoshimura, Nagahisa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (01) : 477 - 484
  • [45] SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY DETECTION OF BRUCH MEMBRANE AND CHORIOCAPILLARIS ABNORMALITIES IN SORSBY MACULAR DYSTROPHY
    Iyer, Prashanth G.
    Zhou, Hao
    Zhang, Qinqin
    Chu, Zhongdi
    Shen, Mengxi
    Shi, Yingying
    Liu, Jeremy
    Trivizki, Omer
    Lam, Byron L.
    Wang, Ruikang K.
    Gregori, Giovanni
    Rosenfeld, Philip J.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2022, 42 (09): : 1645 - 1654
  • [46] Evaluation of the effect of ocular dominance on macular microcirculation via swept-source optical coherence tomography angiography
    Karakucuk, Yalcin
    Eker, Serhat
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2024, 49
  • [47] Macular Choroidal Thickness and Volume in Healthy Pediatric Individuals Measured by Swept-Source Optical Coherence Tomography
    Nagasawa, Toshihiko
    Mitamura, Yoshinori
    Katome, Takashi
    Shinomiya, Kayo
    Naito, Takeshi
    Nagasato, Daisuke
    Shimizu, Yukiko
    Tabuchi, Hitoshi
    Kiuchi, Yoshiaki
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (10) : 7068 - 7074
  • [48] En face swept-source optical coherence tomography in neovascular age-related macular degeneration
    Flores-Moreno, Ignacio
    Arias-Barquet, Luis
    Rubio-Caso, Marcos J.
    Ruiz-Moreno, Jose M.
    Duker, Jay S.
    Caminal, Josep M.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (09) : 1260 - 1267
  • [49] Early Postoperative Changes in Macular Choroidal Thickness After Uncomplicated Phacoemulsification in Patients With and Without Glaucoma: A Swept-Source Optical Coherence Tomography Study
    Sotiropulos, Konstadinos
    Kourkoutas, Dimitrios
    Chatzistefanou, Klio I.
    Droutsas, Konstantinos
    Moschos, Marilita M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (09)
  • [50] Feasibility and Safety of Intraoperative Optical Coherence Tomography-Guided Short-Term Posturing Prescription after Macular Hole Surgery
    Lorusso, Massimo
    Ferrari, Luisa Micelli
    Cicinelli, Maria Vittoria
    Nikolopoulou, Eleni
    Zito, Roberta
    Bandello, Francesco
    Querques, Giuseppe
    Ferrari, Tommaso Micelli
    OPHTHALMIC RESEARCH, 2020, 63 (01) : 18 - 24