DURATION OF PRONE POSITIONING AFTER MACULAR HOLE SURGERY DETERMINED BY SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY

被引:15
|
作者
Sano, Masahiko [1 ]
Inoue, Makoto [1 ]
Itoh, Yuji [1 ]
Kita, Yoshiyuki [1 ]
Hirota, Kazunari [1 ]
Koto, Takashi [1 ]
Hirakata, Akito [1 ]
机构
[1] Kyorin Univ, Sch Med, Kyorin Eye Ctr, 6-20-2 Shinkawa, Mitaka, Tokyo 1818611, Japan
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2017年 / 37卷 / 08期
关键词
macular hole; optical coherence tomography; pars plana vitrectomy; swept-source optical coherence tomography; gas tamponade; RANDOMIZED CONTROLLED-TRIAL; FACE-DOWN; VITREOUS SURGERY; GAS TAMPONADE; VITRECTOMY; REPAIR; CLOSURE; EYES; AIR;
D O I
10.1097/IAE.0000000000001394
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the closure rate of macular hole closure and duration of the prone positioning after macular hole (MH) surgery with two protocols for halting the prone positioning. Methods: The authors studied 129 eyes of 125 consecutive patients with MH who had undergone vitrectomy. In 60 eyes of 59 patients, the prone positioning was halted after detecting an MH closure in the swept-source optical coherence tomographic images (SS group). In 69 eyes of 66 patients, the prone position was halted by the surgeon's decision (conventional group). The MH closure rate and duration of the prone positioning were compared. Results: Clear images of the MH were recorded in the SS group on postoperative Day 1 in 58 eyes (97%). In the SS group, MH closure was detected on postoperative Day 1 in 47 eyes (78%) and Day 2 in 4 eyes (7%). The MH was closed in 58 eyes (97%) in the SS group and 69 eyes (100%) in the conventional group (P = 0.21). None of the eyes had a reopening of the MH. The duration of prone positioning in the SS group was 1.8 +/- 2.5 days, which was significantly shorter than that in the conventional group at 8.4 +/- 4.2 days (P < 0.0001). Conclusion: The SS-OCT protocol can significantly decrease the duration of the prone positioning without a reopening of the MH.
引用
收藏
页码:1483 / 1491
页数:9
相关论文
共 50 条
  • [1] Retinal and choroidal thicknesses measured with swept-source optical coherence tomography after surgery for idiopathic macular hole
    Bardak, Handan
    Gunay, Murat
    Bardak, Yavuz
    Ercalik, Yesim
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (03) : 312 - 318
  • [2] OPTICAL COHERENCE TOMOGRAPHY-GUIDED FACEDOWN POSITIONING FOR MACULAR HOLE SURGERY
    Shah, Sumit P.
    Manjunath, Varsha
    Rogers, Adam H.
    Baumal, Caroline R.
    Reichel, Elias
    Duker, Jay S.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2013, 33 (02): : 356 - 362
  • [3] Swept Source-Optical Coherence Tomography-Guided Facedown Posturing to Minimize Treatment Burden and Maximize Outcome after Macular Hole Surgery
    Sato, Mariko
    Iwase, Takeshi
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (16)
  • [4] MORPHOLOGIC CHARACTERISTICS OF CHRONIC MACULAR HOLE ON OPTICAL COHERENCE TOMOGRAPHY
    Yun, Cheolmin
    Oh, Jaeryung
    Hwang, Soon-Young
    Togloom, Ariunaa
    Kim, Seong-Woo
    Huh, Kuhl
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (10): : 2077 - 2084
  • [5] Swept-source optical coherence tomography features of regressed macular retinoblastoma
    Damodaran, Sourav
    Bajaj, Mandeep S.
    Sharma, Pradeep
    Kumar, Atul
    Chawla, Rohan
    Pujari, Amar
    Garg, Gaurav
    Temkar, Shreyas
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (12) : 2013 - 2018
  • [6] Swept-source Optical Coherence Tomography Angiography Findings in Uveitic Cystoid Macular Edema
    Khochtali, Sana
    Abroug, Nesrine
    Megzari, Kenza
    Gargouri, Mohamed Ali
    Ksiaa, Imen
    Ben Amor, Hager
    Saihi, Emna
    Khairallah, Moncef
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2019, 27 (08) : 1211 - 1223
  • [7] FACEDOWN POSITIONING AFTER VITRECTOMY WILL NOT FACILITATE MACULAR HOLE CLOSURE BASED ON SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY IMAGING IN GAS-FILLED EYES A Prospective, Randomized Comparative Interventional Study
    Zhang, Yong
    Chen, Xiao
    Hong, Lin
    Yan, Ying
    Zeng, Miao
    Huang, Zhijian
    Liu, Ran
    Ding, Qin
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (12): : 2353 - 2359
  • [8] Macular hole surgery with air tamponade and optical coherence tomography-based duration of face-down positioning
    Eckardt, Claus
    Eckert, Tillmann
    Eckardt, Ute
    Porkert, Ute
    Gesser, Caroline
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2008, 28 (08): : 1087 - 1096
  • [9] Morphologic Characteristics of Macular Complications of a Dome-Shaped Macula Determined by Swept-Source Optical Coherence Tomography
    Ohsugi, Hideharu
    Ikuno, Yasushi
    Oshima, Kanako
    Yamauchi, Tomofusa
    Tabuchi, Hitoshi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (01) : 162 - 170
  • [10] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79