Measurements of the radial profile of magnetic field in the Gas-Dynamic Trap using a motional Stark effect diagnostic

被引:7
|
作者
Bagryansky, PA
Deichuli, PP
Ivanov, AA
Korepanov, SA
Lizunov, AA
Murakhtin, SV
Savkin, VY
Den Hartog, DJ
Fiksel, G
机构
[1] Budker Inst Nucl Phys, Novosibirsk 630090, Russia
[2] Univ Wisconsin, Dept Phys, Madison, WI 53706 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2003年 / 74卷 / 03期
关键词
D O I
10.1063/1.1527260
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have implemented a spectral motional Stark effect diagnostic for spatially localized measurements of magnetic field on the Gas-Dynamic Trap (GDT) magnetic mirror device. A 7 A, 40 keV diagnostic neutral hydrogen beam was focused to a current density of 0.25 A/cm(2) in the measurement volume, allowing achievement of a radial resolution of 4.5 cm by viewing the beam at 45degrees with a well-defined light collection chord. The entire Stark spectrum was recorded by a spectrometer with a charge-coupled device detector. Analysis of the splitting of the components of the Stark spectrum directly results in a measurement of local \B\. When operated with deuterium heating neutral beam injection into a hydrogen target plasma, the GDT axial magnetic field is strongly perturbed by plasma diamagnetic effects. Thus,. measurement of the radial pro file of the perturbed magnetic field, combined with equilibrium modeling, will yield an,estimate of the plasma beta. (C) 2003 American Institute of Physics.
引用
收藏
页码:1592 / 1595
页数:4
相关论文
共 50 条
  • [1] Note: Multi-point measurement of |B| in the gas-dynamic trap with a spectral motional Stark effect diagnostic
    Lizunov, A. A.
    Den Hartog, D. J.
    Donin, A. S.
    Ivanov, A. A.
    Prikhodko, V. V.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (08):
  • [2] Pedestal magnetic field measurements using a motional Stark effect polarimeter
    Lanctot, M. J.
    Holcomb, C. T.
    Allen, S. L.
    Fenstermacher, M. E.
    Luce, T. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [3] Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited)
    Pablant, N. A.
    Burrell, K. H.
    Groebner, R. J.
    Holcomb, C. T.
    Kaplan, D. H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [4] MAGNETIC-FIELD PITCH ANGLE DIAGNOSTIC USING THE MOTIONAL STARK-EFFECT
    LEVINTON, FM
    GAMMEL, GM
    KAITA, R
    KUGEL, HW
    ROBERTS, DW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 2914 - 2919
  • [5] Effect of plasma radial electric field on motional Stark effect measurements and equilibrium reconstruction
    Rice, BW
    Burrell, KH
    Lao, LL
    NUCLEAR FUSION, 1997, 37 (04) : 517 - 522
  • [6] Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic
    Foley, E. L.
    Levinton, F. M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (04):
  • [7] Measurement of the plasma radial electric field by the motional Stark effect diagnostic on JET plasmas
    Cortes, SR
    Hawkes, NC
    Lotte, P
    Fenzi, C
    Stratton, BC
    Hobirk, J
    De Angelis, R
    Orsitto, F
    Varandas, CAF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1596 - 1600
  • [8] q profile measurements with the motional Stark effect diagnostic in the DIII-D tokamak
    Rice, BW
    FUSION ENGINEERING AND DESIGN, 1997, 34-35 : 135 - 142
  • [9] q profile measurements with the motional Stark effect diagnostic in the DIII-D tokamak
    Lawrence Livermore Natl Lab, Livermore, United States
    Fusion Eng Des, (135-142):
  • [10] MAGNETIC-FIELD MEASUREMENTS WITH A LITHIUM-BEAM USING ZEEMAN-STARK-EFFECT OR MOTIONAL-STARK-EFFECT
    DULLNI, E
    LEISMANN, P
    MAURMANN, S
    VONREVENTLOW, C
    KUNZE, HJ
    PHYSICA SCRIPTA, 1986, 34 (05): : 405 - 407