Comparison of Neutron Organ and Effective Dose Coefficients for PIMAL Stylized Phantoms in Bent Postures in Cranial and Caudal Irradiation Geometries

被引:2
作者
Sivabhaskar, Sruthi [1 ]
Perry, Alexander [2 ]
Dewji, Shaheen [2 ]
机构
[1] Texas A&M Univ, Dept Phys, College Stn, TX 77843 USA
[2] Texas A&M Univ, Dept Nucl Engn, College Stn, TX 77843 USA
来源
HEALTH PHYSICS | 2021年 / 120卷 / 05期
关键词
effective dose; Monte Carlo; neutron dosimetry; phantom; mathematical; CONVERSION COEFFICIENTS; AIR KERMA; EXPOSURE; PHOTONS; TERMS;
D O I
10.1097/HP.0000000000001382
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radiation dose estimations in the human body are performed using computational reference phantoms, which are anatomical representations of the human body. In previous studies, dose reconstructions have been performed focusing primarily on phantoms in an upright posture, which limits the accuracy of the dose estimations for postures observed in realistic work settings. In this work, the International Commission on Radiological Protection (ICRP) Publication 103 recommendations for monoenergetic neutron plane sources directed downward from above the head (cranial) and upward from below the feet (caudal) for adult female and male reference phantoms were used to calculate organ absorbed and effective dose coefficients. The Phantom with Moving Arms and Legs (PIMAL) and the Monte Carlo N-Particle (MCNP) radiation transport code were used to compute organ-absorbed dose and effective dose coefficients for the upright, half-bent (45 degrees), and full-bent (90 degrees) phantom postures. The doses calculated for each of the articulated positions were compared to those calculated for the upright posture by computing the ratios of the coefficients (45 degrees/upright and 90 degrees/upright). These ratios were used to assess the effectiveness of upright phantoms in providing a comparable estimate when conducting dose estimations and dose reconstructions for articulated positions. This work compiling neutron cranial and caudal posture-specific dose coefficients completes the series of dose coefficients computed for posture-specific ICRP Publication 116 irradiation geometries for monoenergetic photons and neutrons, in addition to cranial and caudal monoenergetic photons. Results reported demonstrated that organ-absorbed dose coefficients for most of the organs in the CRA and CAU irradiation geometries were significantly higher for the bent phantoms than for the upright phantom. Since the upright phantom underestimates the organ-absorbed dose, this demonstrates the impact of posture while performing dose calculations. Organ doses reported in past neutron dose coefficient data were found to omit effects from neutron resonances at energies of 0.435, 1.0, and 3.21 MeV from O-16 in tissue. Reported data notes as high as 60% underestimation for neutron organ-absorbed doses, specifically at the neutron resonance energy region omitted by smoothing. Ongoing studies are examining the effect of resonances on reported neutron organ-absorbed dose coefficients in ICRP 116 geometries.
引用
收藏
页码:559 / 572
页数:14
相关论文
共 30 条
[1]  
Akkurt H., 2009, ASSESSMENT ORGAN DOS
[2]  
Akkurt H, 2007, ORNL/TM- 2007/14)
[3]   CONVERSION COEFFICIENTS FOR PROTON BEAMS USING STANDING AND SITTING MALE HYBRID COMPUTATIONAL PHANTOM CALCULATED IN IDEALIZED IRRADIATION GEOMETRIES [J].
Alves, M. C. ;
Santos, W. S. ;
Lee, C. ;
Bolch, W. E. ;
Hunt, J. G. ;
Carvalho Junior, A. B. .
RADIATION PROTECTION DOSIMETRY, 2017, 175 (01) :75-86
[4]   Organ and effective dose conversion coefficients for a sitting female hybrid computational phantom exposed to monoenergetic protons in idealized irradiation geometries [J].
Alves, M. C. ;
Santos, W. S. ;
Lee, Choonsik ;
Bolch, Wesley E. ;
Hunt, John G. ;
Carvalho Junior, A. B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (24) :7957-8003
[5]   Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries [J].
Bales, K. ;
Dewji, S. ;
Sanchez, E. .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2018, 57 (04) :375-393
[6]   Comparison of Organ and Effective Photon Dose Coefficients for Reference Phantoms in Articulated and Upright Postures in Cranial and Caudal Irradiation Geometries [J].
Bales, Kathryn ;
Dewji, Shaheen .
HEALTH PHYSICS, 2019, 116 (05) :599-606
[7]   Radiation protection of the eye lens in medical workers-basis and impact of the ICRP recommendations [J].
Barnard, Stephen G. R. ;
Ainsbury, Elizabeth A. ;
Quinlan, Roy A. ;
Bouffler, Simon D. .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1060)
[8]   Comparison of conversion coefficients for equivalent dose in terms of air kerma using a sitting and standing female adult voxel simulators exposure to photons in antero-posterior irradiation geometry [J].
Cavalcante, F. R. ;
Galeano, D. C. ;
Carvalho Junior, A. B. ;
Hunt, J. .
RADIATION PHYSICS AND CHEMISTRY, 2014, 95 :158-160
[9]   Dose coefficients for ICRP reference pediatric phantoms exposed to idealised external gamma fields [J].
Chang, Lienard A. ;
Simon, Steven L. ;
Jorgensen, Timothy J. ;
Schauer, David A. ;
Lee, Choonsik .
JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (01) :127-144
[10]   Estimated dose rates to members of the public from external exposure to patients with 131I thyroid treatment [J].
Dewji, S. ;
Bellamy, M. ;
Hertel, N. ;
Leggett, R. ;
Sherbini, S. ;
Saba, M. ;
Eckerman, K. .
MEDICAL PHYSICS, 2015, 42 (04) :1851-1857