Analysis of photovoltaic module energy output under operating conditions in South Africa

被引:3
作者
van Dyk, EE [1 ]
Meyer, EL [1 ]
Scott, BJ [1 ]
O'Connor, DA [1 ]
Wessels, JB [1 ]
机构
[1] Univ Port Elizabeth, Dept Phys, ZA-6000 Port Elizabeth, South Africa
来源
CONFERENCE RECORD OF THE TWENTY SIXTH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE - 1997 | 1997年
关键词
D O I
10.1109/PVSC.1997.654303
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
South Africa does not have any industry standard methodology to evaluate photovoltaic (PV) modules for energy production. The aim of this study is to characterize the energy production of PV modules deployed outdoors at the University of Port Elizabeth (UPE), Summerstrand, South Africa with the view of facilitating such a standard. The system developed for this study was designed to monitor the energy production of seven PV modules under normal operating conditions. An analysis of energy production of three of the PV modules under test, while operating under prevailing outdoor conditions, is given. Measured energy output is also compared with that predicted using an energy model.
引用
收藏
页码:1197 / 1200
页数:4