Joint area constraint had no influence on bone loss in proximal tibia 5 years after total knee replacement

被引:32
作者
Saari, Tuuli [1 ]
Uvehammer, Johan [1 ]
Carlsson, Lons [1 ]
Regner, Lons [1 ]
Karrholm, Johan [1 ]
机构
[1] Gothenburg Univ, Sahlgrenska Univ Hosp, Dept Orthopaed, S-41345 Gothenburg, Sweden
关键词
bone mineral density; dual energy X-ray absorptiometry; total knee replacement;
D O I
10.1002/jor.20358
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
After total knee replacement (TKR) the bone mineral density (BMD) decreases in the proximal tibia. Our aim was to evaluate if changes in constraint of the cemented AMK TKR (DePuy, Johnson & Johnson, Leeds, UK) had any effect on postoperative bone remodeling in the proximal tibia. We used dual-energy X-ray absorptiometry in 43-53 knees to record changes in BMD in three regions of interest around the tibial component up to 5 years after operation with the AMK (DePuy) TKR. The knees had been randomly allocated to receive a flat or a concave tibial insert with retention of the posterior cruciate ligament when preoperative deformity was less severe, and either a concave or a posterior-stabilized (PS) insert with resection of the posterior cruciate ligament when deformity was more pronounced. All designs were associated with loss of BMD in the proximal tibia. The mean bone loss varied from 5 to 23% depending on the region of interest. There were no statistically significant differences between the groups, and the alteration of tibial insert constraint did not influence the bone remodeling. However, low precision values may have impaired the detection of differences. (C) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:798 / 803
页数:6
相关论文
共 24 条
[1]   New polymer materials in total hip arthroplasty - Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters [J].
Digas, G .
ACTA ORTHOPAEDICA, 2005, 76 :4-82
[2]  
HAGSTEDT B, 1980, ACTA ORTHOP SCAND, V51, P963, DOI 10.3109/17453678008990901
[3]   Decreased precision for BMD measurements in the prosthetic knee using a non-knee-specific software [J].
Li, MG ;
Nilsson, KG ;
Nivbrant, B .
JOURNAL OF CLINICAL DENSITOMETRY, 2004, 7 (03) :319-325
[4]   No relationship between postoperative changes in bone density at the proximal tibia and the migration of the tibial component 2 years after total knee arthroplasty [J].
Li, MG ;
Nilsson, KG .
JOURNAL OF ARTHROPLASTY, 2001, 16 (07) :893-900
[5]   Changes in bone mineral density at the proximal tibia after total knee arthroplasty: A 2-year follow-up of 28 knees using dual energy x-ray absorptiometry [J].
Li, MG ;
Nilsson, KG .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (01) :40-47
[6]   The effect of the preoperative bone quality on the fixation of the tibial component in total knee arthroplasty [J].
Li, MG ;
Nilsson, KG .
JOURNAL OF ARTHROPLASTY, 2000, 15 (06) :744-753
[7]   Changes in bone density after cemented total knee arthroplasty - Influence of stem design [J].
Lonner, JH ;
Klotz, M ;
Levitz, C ;
Lotke, PA .
JOURNAL OF ARTHROPLASTY, 2001, 16 (01) :107-111
[8]   A quantitative and qualitative analysis of bone remodelling around custom uncemented femoral stems: a five-year DEXA follow-up [J].
Muller, S ;
Irgens, F ;
Aamodt, A .
CLINICAL BIOMECHANICS, 2005, 20 (03) :277-282
[9]   SCINTIMETRY AFTER TOTAL KNEE ARTHROPLASTY - PROSPECTIVE 2-YEAR STUDY OF 18 CASES OF ARTHROSIS AND 15 CASES OF RHEUMATOID-ARTHRITIS [J].
NILSSON, KG ;
BJORNEBRINK, J ;
HIETALA, SO ;
KARRHOLM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (02) :159-165
[10]  
Pocock SJ, 2013, CLIN TRIALS PRACTICA