Effect of the AutoPulse™ automated band chest compression device on hemodynamics in out-of-hospital cardiac arrest resuscitation

被引:51
作者
Duchateau, Francois-Xavier [1 ]
Gueye, Papa [2 ]
Curac, Sonja [1 ]
Tubach, Florence [4 ]
Broche, Claire [2 ]
Plaisance, Patrick [3 ]
Payen, Didier [2 ]
Mantz, Jean [1 ]
Ricard-Hibon, Agnes [1 ]
机构
[1] Beaujon Univ Hosp, Dept Anaesthesiol & Intens Care, F-92110 Clichy, France
[2] Lariboisiere Univ Hosp, Dept Anesthesiol & Crit Care, Paris, France
[3] Lariboisiere Univ Hosp, Emergency Dept, Paris, France
[4] Bichat Claude Bernard Univ Hosp, Clin Res Unit, Paris, France
关键词
Hemodynamics; Cardiac arrest; Resuscitation; Out-of-hospital; CARDIOPULMONARY-RESUSCITATION; BLOOD-FLOW; PREDICTOR; QUALITY;
D O I
10.1007/s00134-010-1784-x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Guidelines for advanced life support of cardiac arrest (CA) emphasize continuous and effective chest compressions as one of the main factors of cardiopulmonary resuscitation (CPR) success. The use of an automated load distributing chest compression device for CPR is promising but initial studies on survival show contradictory results. The aim of this study was to evaluate the effects of AutoPulse (TM) on blood pressure (BP) in out-of-hospital CA patients. This prospective study included adult patients presenting with in refractory out-of-hospital CA. Invasive arterial BP produced by AutoPulse (TM) was compared to BP generated by manual CPR (Active Compression Decompression). Systolic, diastolic and mean BP and end-tidal carbon dioxide were recorded before and after initiating the automated band device for each patient. The comparison of diastolic BP produced by manual CPR versus automated chest compressions was the primary end point. Hemodynamics in 29 patients are reported and analyzed. Median diastolic BP increased after starting AutoPulse (TM) from 17[11-25] mmHg to 23[18-28] mmHg (P < 0.001). Median systolic BP increased from 72[55-105] mmHg to 106[78-135] mmHg (P = 0.02). Mean BP increased from 29[25-38] mmHg to 36[30-15] mmHg (P = 0.002). On the other hand, End-Tidal CO2 did not increase significantly with AutoPulse (TM) (21[13-36] vs. 22[12-35] mmHg, P = 0.80). In patients with out-of-hospital CA, the use of AutoPulse (TM) is associated with an increased diastolic BP compared to manual chest compressions. While its benefit to survival has yet to be demonstrated, the increase in diastolic and mean BP is a promising outcome for AutoPulse (TM) use.
引用
收藏
页码:1256 / 1260
页数:5
相关论文
共 19 条
  • [1] [Anonymous], 2005, Resuscitation, V67, P213, DOI DOI 10.1016/J.RESUSCITATION.2005.09.018
  • [2] End-tidal carbon dioxide during cardiopulmonary resuscitation in humans presenting mostly with asystole: A predictor of outcome
    Cantineau, JP
    Lambert, Y
    Merckx, P
    Reynaud, P
    Porte, F
    Bertrand, C
    Duvaldestin, P
    [J]. CRITICAL CARE MEDICINE, 1996, 24 (05) : 791 - 796
  • [3] DELGUERCIO LR, 1965, CIRCULATION, V31, P171
  • [4] Duchateau FX, 2003, JEUR, V16, P123
  • [5] DUCROS L, 2010, J EMERG MED IN PRESS
  • [6] Improved neurological outcome with continuous chest compressions compared with 30: 2 compressions-to-ventilations cardiopulmonary resuscitation in a realistic swine model of out-of-hospital cardiac arrest
    Ewy, Gordon A.
    Zuercher, Mathias
    Hilwig, Ronald W.
    Sanders, Arthur B.
    Berg, Robert A.
    Otto, Charles W.
    Hayes, Melinda M.
    Kern, Karl B.
    [J]. CIRCULATION, 2007, 116 (22) : 2525 - 2530
  • [7] GUEUGNIAUD PY, 2006, NEW ENGL J MED, V359, P21
  • [8] Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest - A randomized trial
    Hallstrom, Al
    Rea, Thomas D.
    Sayre, Michael R.
    Christenson, James
    Anton, Andy R.
    Mosesso, Vince N., Jr.
    Van Ottingham, Lois
    Olsufka, Michele
    Pennington, Sarah
    White, Lynn J.
    Yahn, Stephen
    Husar, James
    Morris, Mary F.
    Cobb, Leonard A.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (22): : 2620 - 2628
  • [9] Cardiopulmonary resuscitation with a novel chest compression device in a porcine model of cardiac arrest - Improved hemodynamics and mechanisms
    Halperin, HR
    Paradis, N
    Ornato, JP
    Zviman, M
    LaCorte, J
    Lardo, A
    Kern, KB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (11) : 2214 - 2220
  • [10] IDRIS AH, 1994, CRIT CARE MED, V22, P1827