Exact reconstruction for cone-beam scanning along nonstandard spirals and other curves

被引:36
作者
Ye, Y [1 ]
Zhao, SY [1 ]
Yu, HY [1 ]
Wang, G [1 ]
机构
[1] Univ Iowa, Dept Math, Iowa City, IA 52242 USA
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY IV | 2004年 / 5535卷
关键词
cone-beam CT; exact reconstruction; nonstandard spiral;
D O I
10.1117/12.559087
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this article we consider cone-beam CT projections along a nonstandard 3-D spiral with variable radius and variable pitch. Specifically, we generalize an exact image reconstruction formula by Zou and Pan (2004a) and (2004b) to the case of nonstandard spirals, by giving a new, analytic proof of the reconstruction formula. Our proof is independent of the shape of the spiral, as long as the object is contained in a region inside the spiral, where there is a PI line passing through any interior point. Our generalized reconstruction formula can also be applied to much more general situations, including cone-beam scanning along standard (Pack, et al. 2004) and nonstandard saddle curves, and any smooth curve from one endpoint of a line segment to the other endpoint, for image reconstruction of that line segment. In other words, our results can be regarded as a generalization of Orlov's classical papers (1975) to cone-beam scanning.
引用
收藏
页码:293 / 300
页数:8
相关论文
共 50 条
[31]   An accelerated RAMLA reconstruction algorithm for X-ray cone-beam CT [J].
Zhao, Xing ;
Hu, Jing-jing ;
Yang, Tao ;
Wang, Feng .
INSIGHT, 2013, 55 (05) :237-242
[32]   Region of interest reconstruction from truncated data in circular cone-beam CT [J].
Yu, Lifeng ;
Zou, Yu ;
Sidky, Emil Y. ;
Pelizzari, Charles A. ;
Munro, Peter ;
Pan, Xiaochuan .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) :869-881
[33]   Three Dimensional Image Guided Extrapolation for Cone-Beam CT Image Reconstruction [J].
Nett, Brian .
MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
[34]   Region of interest reconstruction from truncated data in circular cone-beam CT [J].
Yu, LF ;
Xia, D ;
Zou, Y ;
Pan, XC ;
Pelizzari, C ;
Munro, P .
MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 :412-418
[35]   Investigation of effect of reconstruction filters on cone-beam computed tomography image quality [J].
Kavitha Srinivasan ;
Mohammad Mohammadi ;
Justin Shepherd .
Australasian Physical & Engineering Sciences in Medicine, 2014, 37 :607-614
[36]   General fan-beam and cone-beam reconstruction algorithms formula for free-form trajectories [J].
Li, L ;
Chen, ZQ ;
Xing, YX .
2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, :3933-3936
[37]   Development of a cone angle weighted three-dimensional image reconstruction algorithm to reduce cone-beam artefacts [J].
Gomi, T. ;
Koshida, K. ;
Miyati, T. .
DENTOMAXILLOFACIAL RADIOLOGY, 2006, 35 (06) :398-406
[38]   Exact local regions-of-interest reconstruction in spiral cone-beam filtered-backprojection CT: numerical implementation and first image results [J].
Lauritsch, G ;
Tam, KC ;
Sourbelle, K ;
Schaller, S .
MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 :520-532
[39]   Cone-beam CT Data-Driven Pose Correction for Analytic Reconstruction Methods [J].
Cates, Joshua ;
Pan, Yongsheng ;
Battle, Vianney ;
Whitaker, Ross .
MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
[40]   Research on cone-beam computed tomographic reconstruction based on heterogeneous multi-GPU [J].
Cong, Peng ;
Wang, Bing-Xin .
Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2013, 47 (11) :2161-2165