Fouling control in a lab-scale MBR system: Comparison of several commercially applied coagulants

被引:31
作者
Gkotsis, P. K. [1 ]
Batsari, E. L. [1 ]
Peleka, E. N. [1 ]
Tolkou, A. K. [1 ]
Zouboulis, A. I. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Sch Chem, Chem Technol & Ind Chem Sect, Thessaloniki 54124, Greece
关键词
Membrane bioreactors; Fouling control; Coagulant - flocculant agents; Filterability tests; Soluble microbial products; WASTE-WATER TREATMENT; SUBMERGED MEMBRANE BIOREACTOR; ACTIVATED-SLUDGE SYSTEM; CAKE LAYER; SUBSTANCES; FILTRATION;
D O I
10.1016/j.jenvman.2016.03.003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Membrane bioreactors (MBRs) integrate the biological degradation of pollutants with membrane filtration-separation during wastewater treatment. Membrane fouling, which is considered as the main process drawback, stems from the interaction between the membrane material and the (organic or inorganic) foulants, leading to membrane's efficiency deterioration. It is widely recognized that the mixed liquor colloidal and Soluble Microbial Products (SMP) are in principal responsible for this undesirable situation. As a result, the appropriate pretreatment of wastewater feed is often considered as necessary procedure and the coagulation/flocculation (C/F) process is regarded as a relevant viable option for wastewater treatment by MBRs in order to improve the effective removal of suspended solids (SS), of colloidal particles, of natural organic matter (NOM), as well as of other soluble materials. The objective of this study is the application of coagulation/flocculation for fouling control of MBR systems by using several commercially available chemical coagulant/flocculant agents. For this purpose, an appropriate lab-scale continuous-flow, fully automatic MBR system has been assembled and various (inorganic) coagulants (i.e. FeCl3 center dot 6H(2)O, Fe-2(SO4)(3).5H(2)O, FeClSO4, PFS0.3, PAC A9-M, PAC-A16, Al-2(SO4)(3)center dot 18H(2)O, FO4350SSH, NaAlO2) have been examined. Filterability tests and SMP concentration measurements were also conducted in order to investigate the reversible, as well as the irreversible fouling, respectively. Based upon the obtained results and after selecting the most efficient coagulants (FeCl3 center dot 6H(2)O, Fe-2(SO4)(3).5H(2)O, FeClSO4, PAC-A9, PAC-A16), an attempt was subsequently performed to correlate the major fouling indices (i.e. TMP, TTF, SMP concentration) in order to improve the overall process operability by this fouling control method. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:838 / 846
页数:9
相关论文
共 32 条
[1]   Development of a novel fouling suppression system in membrane bioreactors using an intermittent electric field [J].
Akamatsu, Kazuki ;
Lu, Wei ;
Sugawara, Takashi ;
Nakao, Shin-ichi .
WATER RESEARCH, 2010, 44 (03) :825-830
[2]  
[Anonymous], 2010, OECD guidelines for the testing of chemicals: activated sludge, respiration inhibition test (Carbon and Ammonium Oxidation)
[3]  
[Anonymous], 1992, STANDARD METHODS EXA
[4]  
Banti D., 2013, P 3 INT WORKSH MBR N
[5]  
Brindle K, 1996, BIOTECHNOL BIOENG, V49, P601, DOI 10.1002/(SICI)1097-0290(19960320)49:6<601::AID-BIT1>3.0.CO
[6]  
2-S
[7]   Membrane fouling in membrane bioreactors for wastewater treatment [J].
Chang, IS ;
Le Clech, P ;
Jefferson, B ;
Judd, S .
JOURNAL OF ENVIRONMENTAL ENGINEERING, 2002, 128 (11) :1018-1029
[8]   Membrane filtration characteristics in membrane-coupled activated sludge system - the effect of physiological states of activated sludge on membrane fouling [J].
Chang, IS ;
Lee, CH .
DESALINATION, 1998, 120 (03) :221-233
[9]  
Cicek N., 1998, J AM WATER WORKS ASS, V76, P356
[10]   Floc properties and membrane fouling of different monomer and polymer Fe coagulants in coagulation-ultrafiltration process: The role of Fe (III) species [J].
Dong, Hongyu ;
Gao, Baoyu ;
Yue, Qinyan ;
Sun, Shenglei ;
Wang, Yan ;
Li, Qian .
CHEMICAL ENGINEERING JOURNAL, 2014, 258 :442-449