Echo-intensity and fatty infiltration ultrasound imaging measurement of cervical multifidus and short rotators in healthy people: A reliability study

被引:19
作者
Valera-Calero, Juan Antonio [1 ,2 ]
Arias-Buria, Jose Luis [3 ,4 ]
Fernandez-de-las-Penas, Cesar [3 ,4 ]
Cleland, Joshua A. [5 ]
Gallego-Sendarrubias, Gracia Maria [1 ]
Cimadevilla-Fernandez-Pola, Eduardo [1 ]
机构
[1] Univ Camilo Jose Cela, Fac Hlth, Dept Physiotherapy, Madrid, Spain
[2] Univ Rey Juan Carlos, Int Doctoral Sch, Alcorcon, Spain
[3] Univ Rey Juan Carlos, Dept Phys Therapy Occupat Therapy Rehabil & Phys, Alcorcon, Spain
[4] Univ Rey Juan Carlos, Catedra Inst Docencia, Clin Invest Fisioterapia Terapia Manual Punc Seca, Madrid, Spain
[5] Tufts Univ, Sch Med, Dept Publ Hlth & Community Med, Phys Therapy Program, Boston, MA 02111 USA
关键词
Ultrasound imaging; Fatty infiltration; Echo intensity; Reliability; MUSCLE MORPHOLOGY; WHIPLASH; ULTRASONOGRAPHY; QUALITY; SIZE; PAIN;
D O I
10.1016/j.msksp.2021.102335
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: In addition to muscle morphology, ultrasound imaging (US) could be a potential tool to determine muscle quality assessing the echo-intensity and using offline software to quantify the percentage of intramuscular fatty infiltration. Objective: To investigate intra- and inter-rater image measurement reliability of morphological (i.e., crosssectional area, perimeter) and echo intensity features (i.e., mean muscular echo intensity, fat echo intensity cut-offs, fatty infiltrates percentage estimation) of deep neck extensors in asymptomatic subjects. Methods: Brightness-mode images of the cervical spine at C4/C5 were acquired in 25 asymptomatic subjects (40% women, age: 24 years) by an experienced examiner. Cross-sectional area, perimeter and echo-intensity measures of cervical multifidus and short rotators were measured on two separate days (one-week apart) in a randomized order by two assessors. Intra-class correlation coefficients (ICC), standard error of measurement, minimal detectable change, and mean, absolute and percent errors were calculated. Results: Intra- (ICC3,1 0.800-0.989) and inter- (ICC3,2 0.841-0.948) examiner reliability of echo-intensity measures ranged from good to excellent. Women exhibited higher echo-intensity features than men. Intra-examiner reliability of morphological measures was excellent (ICC3,1 0.917-0.974) for multifidus and good-excellent (ICC3,1 0.868-0.987) for short rotators. Inter-examiner reliability of morphological measures also ranged from good to excellent (ICC3,2 0.765-0.965). Men exhibited higher CSA and perimeter than women. No side-to-side differences were observed in any ultrasound measure. Conclusion: This study found that intra- and inter-rater image analysis reliability of muscle morphology, mean echo intensity, and fatty infiltration quantification of cervical multifidus and short rotators at C4/C5 level was good-to-excellent in healthy subjects.
引用
收藏
页数:6
相关论文
共 29 条
[21]   MUSCLE-FAT MRI: 1.5 TESLA AND 3.0 TESLA VERSUS HISTOLOGY [J].
Smith, Andrew C. ;
Parrish, Todd B. ;
Abbott, Rebecca ;
Hoggarth, Mark A. ;
Mendoza, Karl ;
Chen, Yu Fen ;
Elliott, James M. .
MUSCLE & NERVE, 2014, 50 (02) :170-176
[22]   Reliability of cervical muscle volume quantification using magnetic resonance imaging [J].
Snodgrass, Suzanne J. ;
Rutger, de Zoete M. J. ;
Croker, Christopher ;
Yerrapothu, Meghana ;
Elliott, James M. .
MUSCULOSKELETAL SCIENCE AND PRACTICE, 2019, 44
[23]   Rehabilitative ultrasound imaging of the posterior paraspinal muscles [J].
Stokes, Maria ;
Hides, Julie ;
Elliott, James ;
Kiesel, Kyle ;
Hodges, Paul .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2007, 37 (10) :581-595
[24]   Fat infiltration of paraspinal muscles is associated with low back pain, disability, and structural abnormalities in community-based adults [J].
Teichtahl, Andrew J. ;
Urquhart, Donna M. ;
Wang, Yuanyuan ;
Wluka, Anita ;
Wijethilake, Pushpika ;
O'Sullivan, Richard ;
Cicuttini, Flavia M. .
SPINE JOURNAL, 2015, 15 (07) :1593-1601
[25]  
Valera-Calero JA, 2020, MUSCULOSKEL SCI PRAC, V48, DOI 10.1016/j.msksp.2020.102158
[26]   RELIABILITY AND VALIDITY OF PANORAMIC ULTRASOUND IMAGING FOR EVALUATING MUSCULAR QUALITY AND MORPHOLOGY: A SYSTEMATIC REVIEW [J].
Valera-Calero, Juan Antonio ;
Ojedo-Martin, Cristina ;
Fernandez-de-las-Penas, Cesar ;
Cleland, Joshua A. ;
Arias-Buria, Jose Luis ;
Hervas-Perez, Juan Pablo .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (02) :185-200
[27]   Panoramic Ultrasound Examination of Posterior Neck Extensors in Healthy Subjects: Intra-Examiner Reliability Study [J].
Valera-Calero, Juan Antonio ;
Gallego-Sendarrubias, Gracia Maria ;
Fernandez-de-las-Penas, Cesar ;
Cleland, Joshua A. ;
Ortega-Santiago, Ricardo ;
Arias-Buria, Jose Luis .
DIAGNOSTICS, 2020, 10 (10)
[28]   Echo intensity obtained from ultrasonography images reflecting muscle strength in elderly men [J].
Watanabe, Yuya ;
Yamada, Yosuke ;
Fukumoto, Yoshihiro ;
Ishihara, Tatsuro ;
Yokoyama, Keiichi ;
Yoshida, Tsukasa ;
Miyake, Motoko ;
Yamagata, Emi ;
Kimura, Misaka .
CLINICAL INTERVENTIONS IN AGING, 2013, 8 :993-998
[29]   Imaging with ultrasound in physical therapy: What is the PT's scope of practice? A competency-based educational model and training recommendations [J].
Whittaker, Jackie L. ;
Ellis, Richard ;
Hodges, Paul William ;
OSullivan, Cliona ;
Hides, Julie ;
Fernandez-Carnero, Samuel ;
Luis Arias-Buria, Jose ;
Teyhen, Deydre S. ;
Stokes, Maria J. .
BRITISH JOURNAL OF SPORTS MEDICINE, 2019, 53 (23) :1447-1453