Combination of 2-and 3-Dimensional Contrast-Enhanced Transvaginal Sonography for Diagnosis of Small Adnexal Masses

被引:13
作者
Hu, Rong [1 ]
Xiang, Hong [1 ]
Mu, Yuming [2 ]
Feng, Yuling [1 ]
Gu, Linaer [1 ]
Liu, Hui [1 ]
机构
[1] Xinjiang Med Univ, Dept Ultrasonog, Affiliated Hosp 1, Urumqi 830054, Xinjiang, Peoples R China
[2] Xinjiang Med Univ, Dept Echocardiog, Affiliated Hosp 1, Urumqi 830054, Xinjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
adnexal masses; contrast-enhanced sonography; differential diagnosis; gynecologic ultrasound; MALIGNANT OVARIAN MASSES; TUMOR VASCULARITY; ULTRASOUND; CANCER; BENIGN; ULTRASONOGRAPHY; QUANTIFICATION; UTILITY; US;
D O I
10.7863/ultra.33.11.1889
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives The purpose of this study was to evaluate the efficacy of the combination of 2-dimensional (2D) and 3-dimensional (3D) contrast-enhanced sonography in discriminating between benign and malignant small adnexal masses. Methods Selected patients were evaluated with both 2D and 3D contrast-enhanced sonography after conventional sonography before undergoing any surgery. Time-intensity curves for 2D contrast-enhanced sonography were constructed by using contrast-enhanced sonographic software. A vascular perfusion characteristic analysis was achieved by 2D and 3D contrast-enhanced sonography. Results were finally verified by surgery. Results Forty-seven cases of benign and 10 cases of malignant small adnexal masses were discovered. Significant differences in perfusion patterns, time-intensity curve shapes for 2D contrast-enhanced sonography, grayscale contrast-enhanced sonography, and blood flow imaging on 3D contrast-enhanced sonography were observed between benign and malignant masses (P<.05). Two-dimensional contrast-enhanced sonography, 3D contrast-enhanced sonography, parallel combination of 2D and 3D contrast-enhanced sonography, and serial combination of 2D and 3D contrast-enhanced sonography all reached diagnostic sensitivity of 100% for discriminating benign from malignant masses, whereas specificity values were 61.7%, 63.8%, 68.1%, and 57.4%, respectively. Areas under the receiver operating characteristic curves were 0.809, 0.819, 0.840, and 0.787. Conclusions Two-dimensional contrast-enhanced sonography is of high value in distinguishing malignant from benign small adnexal masses; 3D contrast-enhanced sonography provides richer and more useful information for evaluation of these masses. Diagnostic sensitivity of 100% can be achieved when using a serial combination of 2D and 3D contrast-enhanced sonography, although specificity needs further improvement.
引用
收藏
页码:1889 / 1899
页数:11
相关论文
共 29 条
[1]   Transvaginal color Doppler assessment of venous flow in adnexal masses [J].
Alcázar, JL ;
López-García, G .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 17 (05) :434-438
[2]   Adnexal masses: Relative accuracy of sonography and frozen section in predicting final pathology [J].
Aslam, M. F. ;
Ghayoori, R. ;
Khulpateea, N. .
JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2010, 30 (02) :187-189
[3]   Indeterminate Focal Liver Lesions Incidentally Discovered at Gray-Scale US Role of Contrast-Enhanced Sonography [J].
Bartolotta, Tommaso Vincenzo ;
Taibbi, Adele ;
Midiri, Massimo ;
Matranga, Domenica ;
Solbiati, Luigi ;
Lagalla, Roberto .
INVESTIGATIVE RADIOLOGY, 2011, 46 (02) :106-115
[4]   Ovarian cancer [J].
Colombo, Nicoletta ;
Van Gorp, Toon ;
Parma, Gabriella ;
Amant, Frederic ;
Gatta, Gemma ;
Sessa, Cristiana ;
Vergote, Ignace .
CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2006, 60 (02) :159-179
[5]   Clinical utility of three-dimensional US [J].
Downey, DB ;
Fenster, A ;
Williams, JC .
RADIOGRAPHICS, 2000, 20 (02) :559-571
[6]   Estimates of cancer incidence and mortality in Europe in 2008 [J].
Ferlay, J. ;
Parkin, D. M. ;
Steliarova-Foucher, E. .
EUROPEAN JOURNAL OF CANCER, 2010, 46 (04) :765-781
[7]   Early detection of ovarian carcinoma with transvaginal color Doppler ultrasonography [J].
Fleischer, AC ;
Cullinan, JA ;
Peery, CV ;
Jones, HW .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1996, 174 (01) :101-106
[8]   Contrast-enhanced transvaginal sonography of benign versus malignant ovarian masses - Preliminary findings [J].
Fleischer, Arthur C. ;
Lyshchik, Andrej ;
Jones, Howard W. ;
Crispens, Marta ;
Loveless, Mary ;
Andreotti, Rochelle F. ;
Williams, Phillip K. ;
Fishman, David A. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (07) :1011-1018
[9]   Advances in Sonographic Detection of Ovarian Cancer: Depiction of Tumor Neovascularity With Microbubbles [J].
Fleischer, Arthur C. ;
Lyshchik, Andrej ;
Andreotti, Rochelle F. ;
Hwang, Misun ;
Jones, Howard W., III ;
Fishman, David A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (02) :343-348
[10]   Diagnostic Parameters to Differentiate Benign From Malignant Ovarian Masses With Contrast-Enhanced Transvaginal Sonography [J].
Fleischer, Arthur C. ;
Lyshchik, Andrej ;
Jones, Howard W., III ;
Crispens, Marta A. ;
Andreotti, Rochelle F. ;
Williams, Phillip K. ;
Fishman, David A. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (10) :1273-1280