共 29 条
Combination of 2-and 3-Dimensional Contrast-Enhanced Transvaginal Sonography for Diagnosis of Small Adnexal Masses
被引:13
作者:
Hu, Rong
[1
]
Xiang, Hong
[1
]
Mu, Yuming
[2
]
Feng, Yuling
[1
]
Gu, Linaer
[1
]
Liu, Hui
[1
]
机构:
[1] Xinjiang Med Univ, Dept Ultrasonog, Affiliated Hosp 1, Urumqi 830054, Xinjiang, Peoples R China
[2] Xinjiang Med Univ, Dept Echocardiog, Affiliated Hosp 1, Urumqi 830054, Xinjiang, Peoples R China
基金:
中国国家自然科学基金;
关键词:
adnexal masses;
contrast-enhanced sonography;
differential diagnosis;
gynecologic ultrasound;
MALIGNANT OVARIAN MASSES;
TUMOR VASCULARITY;
ULTRASOUND;
CANCER;
BENIGN;
ULTRASONOGRAPHY;
QUANTIFICATION;
UTILITY;
US;
D O I:
10.7863/ultra.33.11.1889
中图分类号:
O42 [声学];
学科分类号:
070206 ;
082403 ;
摘要:
Objectives The purpose of this study was to evaluate the efficacy of the combination of 2-dimensional (2D) and 3-dimensional (3D) contrast-enhanced sonography in discriminating between benign and malignant small adnexal masses. Methods Selected patients were evaluated with both 2D and 3D contrast-enhanced sonography after conventional sonography before undergoing any surgery. Time-intensity curves for 2D contrast-enhanced sonography were constructed by using contrast-enhanced sonographic software. A vascular perfusion characteristic analysis was achieved by 2D and 3D contrast-enhanced sonography. Results were finally verified by surgery. Results Forty-seven cases of benign and 10 cases of malignant small adnexal masses were discovered. Significant differences in perfusion patterns, time-intensity curve shapes for 2D contrast-enhanced sonography, grayscale contrast-enhanced sonography, and blood flow imaging on 3D contrast-enhanced sonography were observed between benign and malignant masses (P<.05). Two-dimensional contrast-enhanced sonography, 3D contrast-enhanced sonography, parallel combination of 2D and 3D contrast-enhanced sonography, and serial combination of 2D and 3D contrast-enhanced sonography all reached diagnostic sensitivity of 100% for discriminating benign from malignant masses, whereas specificity values were 61.7%, 63.8%, 68.1%, and 57.4%, respectively. Areas under the receiver operating characteristic curves were 0.809, 0.819, 0.840, and 0.787. Conclusions Two-dimensional contrast-enhanced sonography is of high value in distinguishing malignant from benign small adnexal masses; 3D contrast-enhanced sonography provides richer and more useful information for evaluation of these masses. Diagnostic sensitivity of 100% can be achieved when using a serial combination of 2D and 3D contrast-enhanced sonography, although specificity needs further improvement.
引用
收藏
页码:1889 / 1899
页数:11
相关论文