Measurement of the effective energy of pulsed X-rays emitted from a Mather-type plasma focus device

被引:6
作者
Miremad, Seyed Milad [1 ]
Bidabadi, Babak Shirani [1 ]
机构
[1] Univ Isfahan, Fac Adv Sci & Technol, Dept Nucl Engn, Esfahan, Iran
关键词
Pulsed x-ray; Plasma focus; Effective energy; LITHOGRAPHY; RADIOGRAPHY;
D O I
10.1016/j.apradiso.2017.04.027
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The current study examined the effective energy of pulsed x-rays emitted from a Mather-type plasma focus device with copper anodes at an energy range of 2-3 kJ using x-ray transmission radiography. Aluminum filters of different thicknesses and dental x-ray film were used. When air gas was used at a constant voltage of 21 kV at 0.3, 0.6, 0.9 and 1.2 mbar, the effective energy of pulsed the x-ray was 10.9, 10.7, 17.3 and 15.8 keV, respectively. At 0.6 mbar of air, as the operating voltage increased to 19, 21 and 23 kV, the effective energy of the x-ray radiation was 10.6, 10.7 and 12.4 keV, respectively. Comprehensive investigation of the characteristics of x-ray emission from plasma focus devices makes it feasible to use this device as an intensive x-ray generator for medical and industrial purposes. The present study is a part of a program which is planned to realize these applications.
引用
收藏
页码:169 / 175
页数:7
相关论文
共 26 条
[1]   Study of x-ray emission from a table top plasma focus and its application as an x-ray backlighter [J].
Beg, FN ;
Ross, I ;
Lorenz, A ;
Worley, JF ;
Dangor, AE ;
Haines, MG .
JOURNAL OF APPLIED PHYSICS, 2000, 88 (06) :3225-3230
[2]   PRODUCTION AND CONFINEMENT OF HIGH-DENSITY PLASMAS [J].
BOSTICK, WH ;
NARDI, V ;
PRIOR, W .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1975, 251 (MAY8) :2-29
[3]  
Chen SC, 2012, MALAYS J MED SCI, V19, P22
[4]  
Correa E. d. L., 2014, DETERMINATION EFFECT
[5]  
Cox J., 1992, PLTR923035 EDW AFB
[6]   Micropinch actuation in the SPEED 2 plasma focus [J].
Decker, G ;
Kies, W ;
Nadolny, R ;
Rowekamp, P ;
Schmitz, F ;
Ziethen, G ;
Koshelev, KN ;
Sidelnikov, YV ;
Sopkin, YV .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 1996, 5 (01) :112-118
[7]  
Fred J., 2008, RADIOLOGY, V248, P254
[8]   Operation of NX2 dense plasma focus device with argon filling as a possible radiation source for micro-machining [J].
Gribkov, VA ;
Srivastava, A ;
Keat, PLC ;
Kudryashov, V ;
Lee, S .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2002, 30 (03) :1331-1338
[9]   TRAJECTORIES OF HIGH-ENERGY ELECTRONS IN A PLASMA FOCUS [J].
HARRIES, WL ;
LEE, JH ;
MCFARLAND, DR .
PLASMA PHYSICS AND CONTROLLED FUSION, 1978, 20 (02) :95-106
[10]   Plasma focus as a possible x-ray source for radiography [J].
Hussain, S ;
Shafiq, M ;
Ahmad, R ;
Waheed, A ;
Zakaullah, M .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 2005, 14 (01) :61-69