Haemodynamics of Different Configurations of a Left Subclavian Artery Stent Graft for Thoracic Endovascular Aortic Repair

被引:17
|
作者
Tricarico, Rosamaria [1 ,6 ]
Tran-Son-Tay, Roger [1 ,2 ]
Laquian, Liza [3 ]
Scali, Salvatore T. [3 ,4 ]
Lee, Teng-Chun [5 ,7 ]
Beck, Adam W. [3 ,8 ]
Berceli, Scott A. [1 ,3 ,4 ]
He, Yong [3 ]
机构
[1] Univ Florida, Dept Biomed Engn, Gainesville, FL USA
[2] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL USA
[3] Univ Florida, Div Vasc Surg & Endovasc Therapy, Gainesville, FL USA
[4] North Florida South Georgia Vet Hlth Syst, Gainesville, FL USA
[5] Univ Florida, Div Thorac & Cardiovasc Surg, Gainesville, FL USA
[6] Nationwide Childrens Hosp, Ctr Regenerat Med, Res Inst, Columbus, OH USA
[7] Univ Calif San Francisco, Div Cardiothorac Surg, San Francisco, CA 94143 USA
[8] Univ Alabama Birmingham, Div Vasc & Endovasc Therapy, Birmingham, AL USA
基金
美国国家科学基金会;
关键词
Aortic arch aneurysm; Branched endograft; Computational fluid dynamics; Haemodynamics; Left subclavian artery stent graft; Thoracic endovascular aortic repair; EDITORS CHOICE; SHEAR-STRESS; ENERGY-LOSS; FEASIBILITY; MANAGEMENT; SOCIETY; FLOW;
D O I
10.1016/j.ejvs.2019.06.028
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Branched stent grafts represent a viable option for left subclavian artery (LSA) revascularisation in patients treated by thoracic endovascular aortic repair (TEVAR) for Zone 2 lesions. This study investigated the haemodynamic performance of different LSA branched stent graft configurations as potential determinants of thrombotic and stroke risks. Methods: A three dimensional aortic arch geometry extracted from post-operative computed tomography images of a TEVAR patient using a single LSA branched aortic endograft was modified in silico to obtain ten potential LSA branched stent graft configurations: five down facing (0-5 - 10 mm aortic protrusion with 10-12 mm internal diameter), four curved (30-60 degrees with antegrade/retrograde orientation), and one LSA orifice misalignment. The 0 mm down facing stent graft was considered base configuration. Computational fluid dynamic analyses were performed to identify differences in pressure, energy, and wall shear stress (WSS) based parameters. Results: Total pressure drop and energy loss variations among configurations were not greater than 5 mmHg (6% of mean arterial pressure) and 5.7 mW (0.7% of cardiac power), respectively. Protrusions up to 5 mm created clinically insignificant flow disturbances. However, stent graft protrusions further into the aortic lumen created more complex haemodynamics, characterised by larger energy loss and more prominent flow recirculation. Protrusion greater than 5 mm into the lumen was associated with larger areas of elevated maximum WSS (>20 Pa) along the outer surface of the branched stent graft. Conclusion: Arterial haemodynamic characteristics are affected by LSA branched stent graft configurations, with pressure drops and energy losses likely to be clinically insignificant. The length of the stent graft protrusion into the aortic lumen generated the largest haemodynamic variations in the aortic system. Protrusions up to 5 mm have smaller risk of potential thrombus generation. Conversely, larger protrusions into the aortic lumen showed more disturbed haemodynamics, suggesting a greater risk of potential thrombus formation, which may be clinically important over time.
引用
收藏
页码:7 / 15
页数:9
相关论文
共 50 条
  • [1] Hemodynamics of different configurations of the left subclavian artery parallel stent graft for thoracic endovascular aortic repair
    Che, Yue
    Zhao, Jiawei
    Zhang, Xuelan
    Luo, Mingyao
    Cao, Xiran
    Zheng, Liancun
    Shu, Chang
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 241
  • [2] Handmade stent graft fenestration to preserve left subclavian artery in thoracic endovascular aortic repair
    Kuo, Huey-Shiuan
    Huang, Jih-Hsin
    Chen, Jer-Shen
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (03) : 587 - 594
  • [3] Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease
    Caronno, R.
    Piffaretti, G.
    Tozzi, M.
    Lomazzi, C.
    Rivolta, N.
    Castelli, P.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (06): : 915 - 918
  • [4] Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease
    R. Caronno
    G. Piffaretti
    M. Tozzi
    C. Lomazzi
    N. Rivolta
    P. Castelli
    Surgical Endoscopy And Other Interventional Techniques, 2006, 20
  • [5] Influence of Left Subclavian Artery Stent Graft Geometry on Blood Hemodynamics in Thoracic Endovascular Aortic Repair
    Xue, Song
    Lu, Tiandong
    Hu, Wenqing
    Xia, Zeyang
    Zhang, Jun
    Lu, Xinwu
    Xiong, Jing
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2025, 147 (02):
  • [6] Revascularisation of the left subclavian artery for thoracic endovascular aortic repair
    Hajibandeh, Shahin
    Hajibandeh, Shahab
    Antoniou, Stavros A.
    Torella, Francesco
    Antoniou, George A.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (04):
  • [7] In Situ Laser Stent Graft Fenestration of the Left Subclavian Artery for Thoracic Endovascular Repair of Type B Aortic Dissection
    Lu, Xinwu
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E49 - E49
  • [8] Effects of in situ fenestration stent-graft of left subclavian artery on the hemodynamics after thoracic endovascular aortic repair
    Qiao, Yonghui
    Mao, Le
    Ding, Ying
    Fan, Jianren
    Luo, Kun
    Zhu, Ting
    VASCULAR, 2019, 27 (04) : 369 - 377
  • [9] Spinal ischaemia after thoracic endovascular aortic repair with left subclavian artery sacrifice: is there a critical stent graft length?
    Kari, Fabian A.
    Saravi, Babak
    Krause, Sonja
    Puttfarcken, Luisa
    Wittmann, Karin
    Foerster, Katharina
    Rylski, Bartosz
    Maier, Sven
    Goebel, Ulrich
    Siepe, Matthias
    Czerny, Martin
    Beyersdorf, Friedhelm
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (02) : 385 - 391
  • [10] Hemodynamic analysis of thoracic endovascular aortic repair with left subclavian artery reconstructed by chimney stent
    Ding, Yunpeng
    Xu, Chunbo
    Yang, Tiequan
    Wang, Shuyuan
    Wang, Di
    Hu, Songjie
    Lang, Dehai
    VASCULAR, 2024,