On-line monitoring in neurointensive care - Enzyme-based electrochemical assay for simultaneous, continuous monitoring of glucose and lactate from critical care patients

被引:38
作者
Jones, DA
Parkin, MC
Langemann, H
Landolt, H
Hopwood, SE
Strong, AJ
Boutelle, MG
机构
[1] Univ London Kings Coll, Dept Chem, London WC2R 2LS, England
[2] Kantonsspital, Res Dept, Neurosurg Lab, CH-4031 Basel, Switzerland
[3] Kantonsspital, Dept Neurosurg, Aarau, Switzerland
[4] Kings Coll Hosp, Dept Neurosurg, London, England
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 2002年 / 538卷
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
flow injection analysis; amperometric sensor; biosensor;
D O I
10.1016/S0022-0728(02)00839-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the development, verification and use of the first dual on-line electrochemical assay system for use with clinical microdialysis. The assay is a flow injection assay using mediated enzyme beds with electrochemical detection. The on-line assay has been specifically designed for use with head trauma patients in neurointensive care, allowing simultaneous measurement of the levels of glucose and lactate present in the dialysate with high time resolution (30 s sampling intervals). The assay is compared with the Yellow Springs 2300 glucose/lactate analyser in simple analyses and during zero net flux experiments. The on-line assay has greater accuracy and precision particularly at low concentrations of glucose and lactate. The rapid nature of this dual on-line system makes it valuable in studying the roles of energy metabolites in the brain extracellular fluid (ECF), and as an important new method for routine clinical monitoring of patients in the neurointensive care unit. Data is shown for monitoring during surgery and in intensive care. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:243 / 252
页数:10
相关论文
共 39 条
[1]   MICRODIALYSIS - THEORY AND APPLICATION [J].
BENVENISTE, H ;
HUTTEMEIER, PC .
PROGRESS IN NEUROBIOLOGY, 1990, 35 (03) :195-215
[2]   BRAIN MICRODIALYSIS [J].
BENVENISTE, H .
JOURNAL OF NEUROCHEMISTRY, 1989, 52 (06) :1667-1679
[3]   ONLINE MEASUREMENT OF BRAIN GLUTAMATE WITH AN ENZYME/POLYMER-COATED TUBULAR ELECTRODE [J].
BERNERS, MOM ;
BOUTELLE, MG ;
FILLENZ, M .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :2017-2021
[4]   ENZYME PACKED-BED SYSTEM FOR THE ONLINE MEASUREMENT OF GLUCOSE, GLUTAMATE, AND LACTATE IN BRAIN MICRODIALYSATE [J].
BOUTELLE, MG ;
FELLOWS, LK ;
COOK, C .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1790-1794
[5]  
Boutelle MG, 1996, ACT NEUR S, V67, P13
[6]   STEADY-STATE THEORY FOR QUANTITATIVE MICRODIALYSIS OF SOLUTES AND WATER INVIVO AND INVITRO [J].
BUNGAY, PM ;
MORRISON, PF ;
DEDRICK, RL .
LIFE SCIENCES, 1990, 46 (02) :105-119
[7]  
DARVELID M, 1996, MONITORING MOL NEURO
[8]  
FELLOWS LK, 1992, J NEUROCHEM, V59, P2141
[9]   The mechanisms controlling physiologically stimulated changes in rat brain glucose and lactate: A microdialysis study [J].
Fray, AE ;
Forsyth, RJ ;
Boutelle, MG ;
Fillenz, M .
JOURNAL OF PHYSIOLOGY-LONDON, 1996, 496 (01) :49-57
[10]   A METHOD FOR ESTIMATION OF HYDROGEN-PEROXIDE BASED ON MEDIATED ELECTRON-TRANSFER REACTIONS OF PEROXIDASES AT ELECTRODES [J].
FREW, JE ;
HARMER, MA ;
HILL, HAO ;
LIBOR, SI .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 201 (01) :1-10