摘要
Composite solution of sol - gel-derived titania and perfluorosuffonated ionomer (Nafion) was used as a solubilizing agent for multiwalled carbon nanotubes (CNT) as well as an encapsulation matrix for alcohol dehydrogenase (ADH) for the fabrication of a highly sensitive and stable amperometric ethanol biosensor. ADH was immobilized within a thin film of CNT-titania-Nafion composite film coated on a glassy carbon electrode. Because of the mesoporous nature of the CNT-titania-Nafion composite film, the present biosensor exhibited remarkably fast response time within 2 s. The presence of CNT in the composite film increases not only the sensitivity of the ethanol biosensor but also the long-term stability of the biosensor. The present biosensor responds linearly to ethanol in the wide ranges from 1.0 X 10(-5) M to 3.0 x 10(-3) M with the sensitivity of 51.6 mA M(-1)cm(-2). The present biosensor showed good long-term stability with 75% of its activity retained after 4 weeks of storage in 50mM phosphate buffer at pH 7.0.
引用
收藏
页码:1524 / 1530
页数:7
相关论文
共 31 条
[1]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[2]   Carbon nanotube electrode for oxidation of dopamine [J].
Britto, PJ ;
Santhanam, KSV ;
Ajayan, PM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 41 (01) :121-125
[3]   Amperometric biosensor for ethanol based on immobilization of alcohol dehydrogenase on a nickel hexacyanoferrate modified microband gold electrode [J].
Cai, CX ;
Xue, KH ;
Zhou, YM ;
Yang, H .
TALANTA, 1997, 44 (03) :339-347
[4]   Amperometric glucose biosensor based on sol-gel-derived metal oxide/Nafion composite films [J].
Choi, HN ;
Kim, MA ;
Lee, WY .
ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) :179-187
[5]   Electrogenerated chemiluminescence from tris(2,2′-bipyridyl)ruthenium(II) immobilized in titania-perfluorosulfonated lonomer composite films [J].
Choi, HN ;
Cho, SH ;
Lee, WY .
ANALYTICAL CHEMISTRY, 2003, 75 (16) :4250-4256
[6]   Carbon nanotube sol-gel composite materials [J].
Gavalas, VG ;
Andrews, R ;
Bhattacharyya, D ;
Bachas, LG .
NANO LETTERS, 2001, 1 (12) :719-721
[7]   Protein electrochemistry using aligned carbon nanotube arrays [J].
Gooding, JJ ;
Wibowo, R ;
Liu, JQ ;
Yang, WR ;
Losic, D ;
Orbons, S ;
Mearns, FJ ;
Shapter, JG ;
Hibbert, DB .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (30) :9006-9007
[8]   Electrochemical biosensing platforms using platinum nanoparticles and carbon nanotubes [J].
Hrapovic, S ;
Liu, YL ;
Male, KB ;
Luong, JHT .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :1083-1088
[9]   HELICAL MICROTUBULES OF GRAPHITIC CARBON [J].
IIJIMA, S .
NATURE, 1991, 354 (6348) :56-58
[10]   Biomolecule-functionalized carbon nanotubes: Applications in nanobioelectronics [J].
Katz, E ;
Willner, I .
CHEMPHYSCHEM, 2004, 5 (08) :1085-1104