Detection and Location of Single Cable Fault by Impedance Spectroscopy

被引:0
作者
Shi, Qinghai [1 ]
Kanoun, Olfa [1 ]
机构
[1] Tech Univ Chemnitz, Chair Measurement & Sensor Technol, Chemnitz, Germany
来源
2014 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) PROCEEDINGS | 2014年
关键词
Time-Domain Reflectometry (TDR); Frequency-Domain Reflectometry (FDR); cable fault location; type of cable fault; Impedance Spectroscopy (IS); input impedance of cable system);
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Time-Domain Reflectometry (TDR) and Frequency-Domain Reflectometry (FDR) are typical methods for cable fault location. Because the TDR method has the worse signal-to-noise ratio (SNR), it is difficult to detect soft cable faults (frays, chafes, and joints) which cause tiny impedance changes in the cable and small reflected signals. The FDR method has better SNR than the TDR method because of using a power signal as incident signals and signal processing for cable fault location. However it is difficult to identify the type of cable fault. A new method using impedance spectroscopy (IS) for cable fault location is described in this paper. With the new method not only cable fault can be located, but also the type of cable fault can be identified. The periods of cable's impedance can locate hard (open and short circuits) and soft wire faults (frays, chafes and joints). The angle of the cable's impedance in low frequency domain can identify the types of the faults. A signal processing algorithm is developed to accurately locate the cable fault and provide enhanced resolution and range. The details and test results with IS system on realistic twisted pair lines are described. Only one single fault is detected in this work.
引用
收藏
页码:595 / 599
页数:5
相关论文
共 11 条
  • [1] Detection and localization of defects in shielded cables by time-domain measurements with UWB pulse injection and clean algorithm postprocessing
    Buccella, C
    Feliziani, M
    Manzi, G
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2004, 46 (04) : 597 - 605
  • [2] Frequency-domain reflectometery for on-board testing of aging aircraft wiring
    Furse, C
    Chung, YC
    Dangol, R
    Nielsen, M
    Mabey, G
    Woodward, R
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2003, 45 (02) : 306 - 315
  • [3] Gonschorek K., 2005, THEORETISCHE ELEKTRO
  • [4] Kaiser Kenneth L., 2005, TRANSMISSION LINES M, P448
  • [5] Philip S., 2001, TRANSMISSION LINES W, P536
  • [6] Shi Q., 2010, P 7 INT MULT SYST SI, P1
  • [7] Shi Q., 2014, IEEE SENSORS J, V14
  • [8] Shi QH, 2013, IEEE IMTC P, P359
  • [9] Wire Fault Location in Coaxial Cables by Impedance Spectroscopy
    Shi, Qinghai
    Kanoun, Olfa
    [J]. IEEE SENSORS JOURNAL, 2013, 13 (11) : 4465 - 4473
  • [10] Shi QH, 2012, IEEE SENSOR, P737