High-Frame Rate Vector Flow Imaging of the Carotid Bifurcation in Healthy Adults: Comparison With Color Doppler Imaging

被引:37
作者
Goddi, Alfredo [1 ]
Bortolotto, Chandra [2 ]
Raciti, Maria Vittoria [2 ]
Fiorina, Ilaria [2 ]
Aiani, Luca [1 ]
Magistretti, Giovanni [1 ]
Sacchi, Andrea [1 ]
Tinelli, Carmine [3 ]
Calliada, Fabrizio [2 ]
机构
[1] Ctr Med SME Diagnost Immagini, Varese, Italy
[2] Univ Pavia, Radiol Unit, Fdn Ist Ricovero & Cura Carattere Sci Policlin Sa, Viale Oberdan 21, I-27100 Pavia, Italy
[3] Fdn Ist Ricovero & Cura Carattere Sci Policlin Sa, Clin Epidemiol & Biometr Unit, Pavia, Italy
关键词
carotid arteries; Doppler imaging; hemodynamic; plane wave imaging; ultrasound; vascular (diagnostic); vector flow imaging; WALL SHEAR-STRESS; BLOOD-FLOW; VELOCITY ESTIMATION; TRANSIENT ELASTOGRAPHY; PLANE-WAVES; ULTRASOUND; ATHEROSCLEROSIS; VISUALIZATION; ATHEROGENESIS; PATTERNS;
D O I
10.1002/jum.14579
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
ObjectivesTo evaluate the carotid bifurcation in healthy adults using a commercial system equipped with high-frame rate vector flow imaging (VFI) based on the plane wave and to compare VFI with color Doppler imaging. MethodsCarotid bifurcation diameters and flow characteristics of 60 vessels in 60 healthy volunteers were evaluated quantitatively and qualitatively to assess complex flow patterns and their extension and duration. ResultsComplex flow in the internal carotid artery (ICA) was associated with a statistically significant difference in the ICA sinus-to-common carotid artery (CCA) diameter ratio (the relative change in diameter between the CCA and ICA sinus.) Vector flow imaging and color Doppler imaging were in accordance when detecting complex flow in 96.7% of cases; in 3.3% of cases, only VFI identified small recirculation areas of short duration. Vector flow imaging highlighted a larger extension of the complex flow (meanSD, 47.7 +/- 28.5 mm(2); median, 45.5 mm(2)) compared with color Doppler imaging (mean, 29.2 +/- 19.9 mm(2); median, 29.5 mm(2)) and better depicted different complex flow patterns; a strong correlation (r=0.84) was found between the ICA sinus-to-CCA diameter ratio and the complex flow extension. Vector flow imaging showed a longer duration of the flow disturbances (mean, 380 +/- 218 milliseconds; median, 352.5 milliseconds) compared with color Doppler imaging (mean, 325 +/- 206 milliseconds; median, 333 milliseconds), and there was a strong correlation (r=0.92). ConclusionsVector flow imaging is as effective as color Doppler imaging in the detection of flow disturbances, but it is more powerful in the assessment of complex flow patterns.
引用
收藏
页码:2263 / 2275
页数:13
相关论文
共 37 条
  • [1] Ultrafast Compound Doppler Imaging: Providing Full Blood Flow Characterization
    Bercoff, Jeremy
    Montaldo, Gabriel
    Loupas, Thanasis
    Savery, David
    Meziere, Fabien
    Fink, Mathias
    Tanter, Mickael
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (01) : 134 - 147
  • [2] Speckle tracking for multi-dimensional flow estimation
    Bohs, LN
    Geiman, BJ
    Anderson, ME
    Gebhart, SC
    Trahey, GE
    [J]. ULTRASONICS, 2000, 38 (1-8) : 369 - 375
  • [3] The influence of flow, vessel diameter, and non-Newtonian blood viscosity on the wall shear stress in a carotid bifurcation model for unsteady flow
    Box, FMA
    van der Geest, RJ
    Rutten, MCM
    Reiber, JHC
    [J]. INVESTIGATIVE RADIOLOGY, 2005, 40 (05) : 277 - 294
  • [4] A Doppler system for dynamic vector velocity maps
    Capineri, L
    Scabia, M
    Masotti, L
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (02) : 237 - 248
  • [5] FLOW-MEDIATED ENDOTHELIAL MECHANOTRANSDUCTION
    DAVIES, PF
    [J]. PHYSIOLOGICAL REVIEWS, 1995, 75 (03) : 519 - 560
  • [6] Du Y., 2017, US Patent application, Patent No. [20170071576A1, 20170071576]
  • [7] Cross-beam vector Doppler ultrasound for angle-independent velocity measurements
    Dunmire, B
    Beach, KW
    Labs, KH
    Plett, M
    Strandness, DE
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (08) : 1213 - 1235
  • [8] COMBINED VECTOR VELOCITYAND SPECTRAL DOPPLER IMAGING FOR IMPROVED IMAGING OF COMPLEX BLOOD FLOWIN THE CAROTIDARTERIES
    Ekroll, Ingvild Kinn
    Dahl, Torbjorn
    Torp, Hans
    Lovstakken, Lasse
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (07) : 1629 - 1640
  • [9] Ultrasonic colour Doppler imaging
    Evans, David H.
    Jensen, Jorgen Arendt
    Nielsen, Michael Bachmann
    [J]. INTERFACE FOCUS, 2011, 1 (04) : 490 - 502
  • [10] Giddens DP, 1983, FLUID DYNAMICS LOCAL, P38