Development of a Ring PET Insert for MRI

被引:0
作者
Bauer, Chris [1 ]
Stolin, Alexander [1 ]
Proffitt, James [2 ]
Martone, Peter [1 ]
Brefczynski-Lewis, Julie [1 ]
Lewis, James [1 ]
Hankiewicz, Janusz [3 ]
Raylman, Ray [1 ]
Majewski, Stan [1 ]
机构
[1] W Virginia Univ, Morgantown, WV 26505 USA
[2] Ait Technol, Newport News, VA 23606 USA
[3] Univ Colorado, Colorado Springs, CO 80918 USA
来源
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2013年
关键词
SYSTEM; HAT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Our research group constructed a 12-module PET detection ring composed of Hamamatsu multi-pixel photon counter (MMPC) silicon photomultiplier (SiPM) detectors placed in a ring that is fully MRI compatible. This brain imager can be placed around the head of a patient (clinical setting) or subject (research setting) and allow for comfortable upright imaging. However, an alternative way to use this device, as enabled by the technology, is to indeed scan individuals in the supine position in conjuncture with current MRI systems. This PET prototype is able to image simultaneously as the MRI scan is occurring, thus maximizing co-registration and the accuracy of the assignment of metabolically active voxels to their anatomically correct counterparts as identified by the MR image. In this study, we first conducted some basic instrumentation tests to ensure the device was functioning properly outside of the MRI, and additionally scan some phantoms (Derenzo; Hoffman Brain) to assess the quality in which our brain imager is able to produce adequate images. After these initial studies, we conducted multiple different experiments inside a 3 Tesla MRI in order to see how the magnetic field would influence the operation of the PET imager and vice versa. Through simultaneous PET/MRI scanning of a Hoffman brain phantom filled with F-18 radioactivity and water, it was shown that the quality of the MR image was largely unaffected by the PET imager. Furthermore, although the quality of PET imaging was affected by the RF pulsing, an acceptable PET image was nevertheless produced. As we discuss following the results, the success of this study shows that our brain imager is indeed MR compatible, and that next generation devices based on its concepts will continue to improve combined PET/MRI functionality. As two of the major advantages of this imager are the potential for low-dose scanning and its adaptability to any MRI scanner, this study suggests that PET/MRI brain imaging with low dose is in principle possible using an insert which could be adapted to any MRI scanner, using standard RF coils for that scanner.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Improving PET imaging for breast cancer using virtual pinhole PET half-ring insert
    Mathews, Aswin John
    Komarov, Sergey
    Wu, Heyu
    O'Sullivan, Joseph A.
    Tai, Yuan-Chuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (18) : 6407 - 6427
  • [2] Studying the effects of metallic components of PET-insert on PET and MRI performance due to gradient switching
    Moghadam, Narjes
    Espagnet, Romain
    Bouchard, Jonathan
    Lecomte, Roger
    Fontaine, Rejean
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (07)
  • [3] Performance of a PET Insert for High-Resolution Small-Animal PET/MRI at 7 Tesla
    Stortz, Greg
    Thiessen, Jonathan D.
    Bishop, Daryl
    Khan, Muhammad Salman
    Kozlowski, Piotr
    Retiere, Fabrice
    Schellenberg, Graham
    Shams, Ehsan
    Zhang, Xuezhu
    Thompson, Christopher J.
    Goertzen, Andrew L.
    Sossi, Vesna
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (03) : 536 - 542
  • [4] Development of a full-ring "add-on PET" prototype: A head coil with DOI-PET detectors for integrated PET/MRI
    Nishikido, F.
    Fujiwara, M.
    Tashima, H.
    Akram, M. S. H.
    Suga, M.
    Obata, T.
    Yamaya, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 863 : 55 - 61
  • [5] Development and Initial Results of a Brain PET Insert for Simultaneous 7-Tesla PET/MRI Using an FPGA-Only Signal Digitization Method
    Won, Jun Yeon
    Park, Haewook
    Lee, Seungeun
    Son, Jeong-Whan
    Chung, Yina
    Ko, Guen Bae
    Kim, Kyeong Yun
    Song, Junghyun
    Seo, Seongho
    Ryu, Yeunchul
    Chung, Jun-Young
    Lee, Jae Sung
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (06) : 1579 - 1590
  • [6] MRI compatibility study of a prototype radiofrequency penetrable oval PET insert at 3 T
    Akram, Md Shahadat Hossain
    Nishikido, Fumihiko
    Levin, Craig S.
    Takyu, Sodai
    Obata, Takayuki
    Yamaya, Taiga
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 42 (4) : 382 - 390
  • [7] MR Performance in the Presence of a Radio Frequency-Penetrable Positron Emission Tomography (PET) Insert for Simultaneous PET/MRI
    Lee, Brian J.
    Grant, Alexander M.
    Chang, Chen-Ming
    Watkins, Ronald D.
    Glover, Gary H.
    Levin, Craig S.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (09) : 2060 - 2069
  • [8] Hybrid PET/MRI Insert: B0 Field Optimization by Applying Active and Passive Shimming on PET Detector Level
    Wehner, Jakob
    Schulz, Volkmar
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (03) : 644 - 649
  • [9] Development of a PET Scanner for Simultaneously Imaging Small Animals with MRI and PET
    Thompson, Christopher J.
    Goertzen, Andrew L.
    Thiessen, Jonathan D.
    Bishop, Daryl
    Stortz, Greg
    Kozlowski, Piotr
    Retiere, Fabrice
    Zhang, Xuezhu
    Sossi, Vesna
    SENSORS, 2014, 14 (08) : 14654 - 14671
  • [10] Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain
    Jung, Jin Ho
    Choi, Yong
    Jung, Jiwoong
    Kim, Sangsu
    Lim, Hyun Keong
    Im, Ki Chun
    Oh, Chang Hyun
    Park, Hyun-wook
    Kim, Kyung Min
    Kim, Jong Guk
    MEDICAL PHYSICS, 2015, 42 (05) : 2354 - 2363